• Title/Summary/Keyword: Insure

Search Result 240, Processing Time 0.027 seconds

Perceptions of Distance University Learners' Satisfaction on Online Lecture Content by Age Group (우수 온라인 강의콘텐츠에 대한 원격대학 학습자의 연령별 인식)

  • Jung, Hyeryung;Woo, Younghee
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.7
    • /
    • pp.429-437
    • /
    • 2020
  • In this study, we examine the satisfaction and dissatisfaction factors on the perceptions of online lecture content among open and distance university learners, especially focusing on age groups differences. The result of the study shows that clear differences exist between age groups in regards to the factors which insure excellent course in online learning. For example, young adults in their 20s and 30s determined 'useful for practical life, 'screen sensitive to audiovisual', and 'recently created lectures' as the most influential factors for online learning content satisfaction. However, older age groups in their 40s and above apparently showed a high preference for factors such as 'instructor's enthusiasm and attitude', and 'clear and easy-to-understand explanations.' The findings of the study imply that learners' recognition concerning content satisfaction may differ depending on age groups. Moreover, this study suggests that considering the growing importance of online learning in relation to the COVID-19 pandemic, age groups should be considered in developing online course content.

A Study on Characteristics of pH Control with Amines in the Secondary Side of Nuclear Power Plants (원전 2차 계통에서 아민의 pH 제어 특성 연구)

  • Rhee, In-H.;Ahn, Hyun-Kyoung;Park, Byung-Gi;Jun, Gwon-Hyuk;Ho, Song-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.3112-3118
    • /
    • 2010
  • The pH control agent in PWRs, to insure the integrity of steam generator, was changed from ammonia to ethanolamine(ETA) which decreased pH at condensate system and low pressure feedwater heater drain system, so that several amines were investigated for the selection of the optimum amine. There was no single alternative amine to meet the optimum condition. The more volatile ammonia provides the higher pH in condensate, while the less volatile ETA increases the pH in wet steam area. Thus, the combined amine of ammonia and ETA is able to equally raise the pH in both region so that the flow accelerated corrosion be reduced in the every system of the secondary side and the integrity of steam generator be also improved in pressurized water reactors (PWRs).

A Study on the Development of Super Low-loss Type Pole Transformer Using the Hybrid Insulation (혼합절연을 이용한 초저손실급 주상변압기 개발에 관한 연구)

  • Min, Yun-Hong;Shin, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.84-93
    • /
    • 2007
  • The pole transformer is one of the most important facility to insure the stability of electric power supply. which distributes electricity to customers directly. However there are a lot of defects which are caused by manufacturing fails(in 3 years) or deterioration (in 13 years), so we need a more improved transformer which insures quality. This thesis talks about the development of the new-type transformer using the hybrid insulation that is durable thermally, mechanically, and electrically. It would show how to lay out and produce the transformer using the hybrid insulation. And finally we are sure that we could increase the utilization rate of a transformer by 160% as compared with its own capacity through the overload test. Also, we carried out the examination about the short-circuit and insulation with a 100[kVA] model transformer, so that we expound the analysis of magnetic-mechanical forces intensity and the measure for improving short-circuit efficiency.

An Efficiency of Diagnostic Ultrasonography in Taking Side View of Medical Examination (진사적(診査的) 측면(側面)에서 본 초음파진단(超音波診斷)의 효율성(效率性))

  • Moon, Soo-Hyung;Han, Hye-Jin;Kim, Kang-Sueck
    • The Journal of the Korean life insurance medical association
    • /
    • v.1 no.1
    • /
    • pp.123-132
    • /
    • 1984
  • Among the person who want to insure, there are not only fair persons who want to become the insurance with not realizing that one was not infected with certain disease but also someones on purpose to overcome the disease through the insurance company with be recognized by oneselves. However, it was found that the ultrasonography and exact effects of medical examination with the existing medical equipments of the insurance company could not be expected. We present some several proven examples for the purpose of getting the advanced effects in medical examination by utilizing the ultrasonic device which is not harmful to human body presently as far as known. We could find affirmation through the check of ultrasonography from 907 cases, in our Department of Medical selection that many portion of the cases checked the medical examination have the present condition of illness even though they enjoy social life with good health and finally the conclusions we have learned are as follows; The aged cases show the increase of rate of possessing disease and man shows 2.2 times of possessing disease than woman. Fatty infiltration of liver take portion of 74.7% from the case checked. 12 cases of cholelithiasis are not conscious of symptom at all. Through the check of ultrasonography in obstetrics and gynecology, myoma uteri be showed high rate of 72.2% from the case of possessing disease. In Case of the potential pregnancing woman it made clear to find pregnancy which was undistincted still more also know the existence and nonexistence of fetal death when pregnancy expected.

  • PDF

p-Version Finite Element Model of Stiffened Plates by Hierarchic $C^0$-Element (계층적 $C^0$ - 요소에 의한 보강판의 p-Version 유한요소 모델)

  • 홍종현;우광성;신영식
    • Computational Structural Engineering
    • /
    • v.9 no.1
    • /
    • pp.33-45
    • /
    • 1996
  • A general stiffener element which includes transverse shear deformation is formulated using the p-version finite element method. Hierarchic C/sup o/-shape functions, derived from Integrals of Legendre polynomials, are used to define the assembled stiffness matrix of the stiffener with respect to the local reference frame is transformed to the plate reference system by applying the appropriate transformation matrices in order to insure compatibility of displacements at the junction of the stiffener and plate. The transformation matrices which account for the orientation and the eccentricity effects of the stiffener with respect to the plate reference axes are used to find local behavior at the junction of the stiffener and the relative contributions of the plate and stiffener to the strength of the composite system. The results obtained by the p-version finite element method are comared with the results in literatures, especially those by the h-version finite element analysis program, MICROFEAP-II.

  • PDF

In-Site Application of Heavyweight Concrete for Radiation Shielding (방사선 차폐용 중량콘크리트의 현장 적용성)

  • Yang, Seung-Kyu;Um, Tae-Sun;Lee, Jong-Ryul;Kim, Yong-Ho;Wu, Sang-Ik;Kim, Tae-Bong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.577-580
    • /
    • 2008
  • This paper was discussed about in-site application of heavyweight(or high density) concrete. Heavyweight concrete was placed with the method of conventional. Placement of conventionally mixed heavyweight concrete is subject to the same considerations of quality control as normal density concrete, except that it is far more susceptible to variations in quality due to improper handling. It is particularly subject to segregation during placement. Segregation of heavyweight concrete results not only in variation of strength but, far more importantly, in variation in density that are intolerable for work this type, since this adversely affects shielding properties. Heavyweight concrete materials and heavyweight concrete should be sampled and tested prior to and during construction to insure conformance with applicable standards and specifications.

  • PDF

A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building (사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구)

  • Jang, Ji-Hoon;Kim, Hyeonsoo;Auh, Jin-Sun;Leigh, Seung-Bok;Kim, Byungseon-Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.

Spreading Beam Poastic Hinging Zone of the High-Strength R/C Beam-Column Joints Using the Vertically Anchored Intermediate Reinforcements (수직앵커형 중간철근으로 보강된 고강도 철근콘크리트 보_-기둥 접합부의 소성힌지 확산)

  • 유영찬;이원호;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.4
    • /
    • pp.169-179
    • /
    • 1995
  • The purpose of this study is to spread beam plastic hinging zone of the high-strength($f'_c=700kg/cm^2$) reinforced concrete beam-column joints away from the column face by vertically anchored intermediate reinforcements. The newly proposed intermediate reinforcements which are vertically anchored by interlinking each intermediate rebars are tested to insure the ductile behavior of R /C beam-column joins. Main variable is the shape of intermediate reinforcements. From the test results, the newly proposed intermediate rebar detail can move arid expand the beam plastic hinging zone about 1.Od from column face and can delay the strength decay of the high-strength R /C beam-column joint. Also energy dissipation capacity of specimen IV-1.OD10 which is reinforced by vertically anchored intermediate rebars about 1.0d is 1.6 times as high as the specimen CM-STAN which is designed by ACI318-89.

Assessing Methodological Quality of Acupuncture Clinical Trials of Korea (한국 침 임상시험의 질 평가 및 분석)

  • Park, Ji-Eun;Kang, Kyung-Won;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.24 no.1
    • /
    • pp.127-135
    • /
    • 2007
  • Objectives: To evaluate the methodological quality of Korean Acupuncture Clinical trials Methods : Two independent researchers reviewed 12 protocols of Acupuncture clinical trials which were conducted in Korea 2006. Also, Survey Principal Investigator of those was conducted. We compare the results of protocol review with investigator reponses of actual practice. Quality assessment consisted of 5 items including random sequence generation, randomization method, allocation concealment, subject blinding, assessor blinding. Results : Randomization was performed using the proper procedure to insure that treatment assignment is unbiased and concealed from subjects in all clinical trials, According to protocols, 6(50%) of 12 clinical trials used computer-generated random numbers, 6(50%) remaining trials didn't describe the randomization method. Also all trials used appropriate randomization methods on the basis of the survey results: 8 trials used computer-generated random number, 2 used random table. Of 7 protocols in which allocation concealment was stated, 5(71%) reported appropriate method (Calling a central office or statisticians, Sealed opaque envelopes). However according to survey, 5(42%) of 12 trials used inappropriate allocation concealment (Keeping a master randomization list and referring to when subject entered the trial). In addition, the result of protocol review and survey response was not coincident in 5(42%) trials. Subject blinding was conducted in all except 1 clinical trials. Although 11(92%) of 12 trials were conducted using assessor blinding in actual practice, only 7(58%) reported that in protocol. Conclusion : Although randomization and blinding were conducted adequately, allocation concealment was used inadequately, Not only appropriate allocation concealment, but also every quality assessment item including randomization, blinding should be stated in more detail in protocol.

  • PDF

A Study of New DC Pin-to-pin Parametric Test of VLSI Device using Communication (통신용 VLSI 소자의 새로운 편간 DC 파라메터 테스트 연구)

  • 박용수;유흥균
    • The Journal of Information Technology
    • /
    • v.2 no.2
    • /
    • pp.235-250
    • /
    • 1999
  • The test of digital VLSI devices is to insure that the device will perform all of its designed functions while in the worst-case environments. According to increasing the integration of the communication device, there are important consideration about the improvement of the reliability in the product. To improve the reliability of the device, the test parameters and test time are increased. There are basically three kinds of tests: functional, DC parametric, and AC parametric. There are no pin-to-pin short test and pin-to-pin leakage test in the present test items to analysis the characteristics and reliability of the device. The purpose of the paper is to model the pin-to-pin phenomenon and propose to modify the test method and to test the new pin-to-pin DC parameters. These modified and additive test items were applied to product test and confirmed to improve the reliability of product test.

  • PDF