The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

A Study on the reliability analysis of Forest Fire on Polymer Insulators (폴리머 애자의 산불 신뢰성 평가 연구)

  • Lee, Won-Kyo;Choi, In-Hyuk;Hwang, Kab-Cheol;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.460-461
    • /
    • 2008
  • The forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

  • PDF

The Electrical Breakdown Characteristics of Broken Toughened Glass Stem Insulator (장간유리애자 파손시 절연파괴 특성)

  • Jung, Jong-Wook;Jung, Jin-Soo;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1398-1406
    • /
    • 2008
  • This paper describes the electrical breakdown characteristics of broken toughened glass stem insulators by comparing with those of sound ones. The broken toughened glass stem insulators were taken from the electric railway field. According to the international standards, the sound and broken toughened glass stem insulators were tested in electrical strength. In the test, the power frequency voltage and the impulse voltage with a standard waveform were applied to the insulators. The power frequency voltage tests were carried out under both dry and wet condition and the impulse voltage tests under only dry condition. The acquired results were compared one another and discussed in electrical breakdown characteristic by analyzing the flashover progress pictures. As a result, the electrical strength of the broken toughened glass insulators was acquired and the processes of the surface breakdown on the toughened glass insulators were confirmed.

The Application Improvement Plan of Polymer Insulators for Overhead Transmission Lines (가공송전선로 폴리머애자 적용 개선 방안)

  • Min, Byeong-Wook;Kim, Tai-Young;Choi, Jin-Sung;Shin, Seung-Bum;Lee, Si-Young;Won, Gyeong-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.465-466
    • /
    • 2011
  • The global trend is to make transmission lines light weight and compact by using insulators and other equipment made of advanced materials. In Korea, the diversification of insulators supply route has begun in order to obtain price competitiveness. In May 1999, polymer insulators were finally introduced for the first time and installed to the 154kV transmission lines. After that, the construction and procurement standards were made and domestic polymer insulators were developed. And then, foreign and domestic manufacturers were registered in KEPCO as qualified insulator suppliers. As of 2010, purchasing polymer insulators by competitive bidding from foreign and domestic manufacturers has been possible. For this reason, it was decided to reduce the use of porcelain insulators and increase the use of polymer insulators taking the installation price into consideration

  • PDF

A Study on the Properties of 36,000lb Porcelain Insulators by Contained Alumina of Raw Materials

  • Choi In-Hyuk;Choi Jang-Hyun;Jung Yoon-Hwan;Lee Dong-Il
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.1
    • /
    • pp.8-13
    • /
    • 2005
  • In order to analyze the properties of domestically produced 36,000lb porcelain insulators by change of the alumina addition to raw materials, 36000lb ball socket type suspension insulators that were manufactured in 1989, 1995 and 2001 were removed from transmission lines and an experiment was performed. The results indicated that 8 [wt.%] alumina, which influences the mechanical properties and arc resistance properties in the case of insulators that were manufactured in 1989 was contained, and the relative density and the fracture toughness of insulators appeared by 94.2% and 1.4 [MpaㆍM/sup 1/2/], respectively. However, 12 [wt.%] alumina was contained in the case of insulators that were manufactured in 1995, and the relative density and the fracture toughness of insulators appeared preferably lower by 92% and 1.3 [MpaㆍM/sup 1/2/], respectively. The greatest amount of alumina was contained by 17 [wt.%] in the case of insulators that were manufactured in 2001. It was confirmed that the electrical and mechanical characteristics such as the relative density and the fracture toughness appeared remarkably by 96% and 1.7 [Mpaㆍm/sup 1/2/], respectively.

Various Factors Influencing the Lifetime of Suspension-Type Porcelain Insulators for 154 kV Power Transmission Lines

  • Choi, In Hyuk;Park, Joon Young;Kim, Tae Gyun;Yoon, Yong Beum;Yi, Junsin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.151-154
    • /
    • 2017
  • In this article, we investigated the various influencing factors that degraded the lifetime of suspension insulators in 154 kV transmission lines, and showed the possible solutions to avoid such breakdowns. With respect to achieve safety, reliability and aesthetical considerations, the characteristics of transmission and distribution network power cables should be improved. Suspension insulators are particularly important to study, as they have developed to be the main component of transmission lines due to their ability to withstand the electrical conductivity of high-voltage power transmission. Suspension insulators are mostly made from glass, rubber and ceramic material due to their high resistivity. In Korea, porcelain suspension insulators are typically used in the transmission line system, as they are cheaper and more flexible compared to other types of insulators. This is effective from preventing very high and steep lightening impulse voltages from causing the breakdown of suspension insulators used in power lines. Other influential factors affect the lifetime of suspension insulators that we studied include temperature, water moisture, contamination, mechanical vibration and electrical stress.

Hardness Profiles of Porcelain Insulators by Climate Changes (기후 변화에 따른 자기 애자의 시멘트 경도 변화)

  • Lee, Joohyun;Kim, Hong-Sik;Kim, Joondong;Choi, In-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.1
    • /
    • pp.24-28
    • /
    • 2018
  • Insulators used in overhead transmission lines are continuously exposed to a number of mechanical and electrical stresses owing to external environmental factors, resulting in corrosion, reduction in durability, and deterioration. Widely used porcelain insulators are fabricated with cement and porcelain and are especially common in Korea. Changes in the hardness and chemical reactivity of the cement increase the leakage and fault currents and increase the possibility of flashover due to insulation breakdown. Therefore, it is important to evaluate the durability and defects of porcelain insulators. Studies on the reliability of various evaluation methods are needed to prevent accidents by accurately determining the replacement timing and potential defects in porcelain insulators. In this study, the hardness of the cement part of the porcelain insulator was measured using the Vickers hardness test and its composition was analyzed by energy dispersive spectroscopy and X-ray diffraction analysis. The performance of the insulators was compared in two different regions with varying climatic conditions. This study presents an evaluation method of the defects in porcelain insulators by measuring humidity, which can also be used to assess the reliability of the insulators.

The Comparison of EPDM and Silicone in Housing Materials of Polymeric Suspension Insulators (EPDM 및 실리콘 재질의 폴리머현수애자의 특성 비교)

  • Lee, Byung-Sung;Lee, Jae-Bong;Song, Il-Keun;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.6-10
    • /
    • 2003
  • In our country, the housing materials of polymeric outdoor insulators have mainly been used EPDM or silicone rubber. EPDM housing materials had been widely used in the field for the first time. The reason why silicone has the high cost of production. But recently, most of the manufacturers that newly developed polymeric insulators make its choice of silicone housing. EPDM showed a good resistance to tracking. We compared the various characteristics for EPDM and silicone insulators that have similar type and design. Silicone insulators have more performance in flashover voltage test and leakage current measurement because of a good water repellent than EPDM ones. Also, the property of EPDM compared with silicone insulators greatly decreased after aging test in combined acceleration ageing facilities for 1000 hours.

  • PDF

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

The Study of relation most suitable betweenPantograp interface And Neutral Section (전기철도 절연구분장치와 팬터그래프 인터페이스 최적화에 관한 연구)

  • Kim, In-Chol
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.325-329
    • /
    • 2002
  • This paper is intended as an investigation of the interface between Neutral section insulators and pantograph interface. Neutral section insulators are installed at the boundary between AC catenary system and DC catenary system, which should provide electrical insolation between two different catenary systems and pass the trains without interruption. As the number of the pantographs installed on the train increased, which is necessary for the VVVF inverter drive trains introduced in recent years, there occurs an serious aspects of the interaction between pantographs and Neutral section insulators. These effects hinder the automatic switch operation of MCB(Main Circuit Breaker) after passing through the section insulators, and lead to the extra-ordinary wear of FRP insulator material of section insulators. Countermeasures in terms of the interface between the Neutral secton insulators and electric collection system of train are provided too.

  • PDF