• Title/Summary/Keyword: Insulation life

Search Result 287, Processing Time 0.019 seconds

Comparison of Environmental Conditions and Insulation Effect between Air Inflated and Conventional Double Layer Greenhouse (공기주입 및 관행 이중피복온실의 재배환경 및 단열성능 비교)

  • Jayasekara, Shanika N.;Na, Wook H.;Owolabi, Abdulhameed B.;Lee, Jong W.;Rasheed, Adnan;Kim, Hyeon T.;Lee, Hyun W.
    • Journal of Bio-Environment Control
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2018
  • This study was conducted to determine which greenhouse provided good environmental conditions for strawberry production, and performed better at conserving energy. Temperature, RH, VPD, $CO_2$, solar radiation, yield, and fuel consumption were the parameters analyzed. The temperatures of both greenhouses were well controlled in order to provide optimal day and night temperatures for strawberry production. The air inflated double layer greenhouse had higher RH values (more than 90% at night), which led to higher disease occurrence, in comparison to the conventional double layer greenhouse. Furthermore, the air inflated double layer greenhouse had lower VPD values than the conventional double layer greenhouse. Therefore, better RH and VPD were observed in the conventional double layer greenhouse. Higher $CO_2$ concentration was observed in the air inflated double layer greenhouse while the conventional double layer greenhouse ventilated better than the air inflated greenhouse, because of its side ventilators. Moreover, higher solar radiation in the conventional double layer greenhouse resulted in higher yield, in comparison to the air inflated double layer greenhouse. Thus, we can conclude that the conventional double layer greenhouse provided a better environment for crop growth, in comparison to the air inflated double layer greenhouse. Regarding fuel consumption, the air inflated double layer greenhouse had lower fuel consumption than the conventional double layer greenhouse. Therefore, from an energy consumption point of view, we can conclude that the air inflated double layer greenhouse performed better than the conventional double layer greenhouse.

An Innovative Solution for the Power Quality Problems in Induction Motor by Using Silica and Alumina Nano Fillers Mixed Enamel for the Coatings of the Windings

  • Mohanadasse, K.;Sharmeela, C.;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1621-1625
    • /
    • 2015
  • Power quality has always been a concern of power engineers. Certainly an argument can be successfully made that most parts of power engineering have the ultimate objective to improve power quality. AC motors were widely used in industrial and domestic applications. Generally, AC motors were of two types: Induction and Synchronous motors. In motor many parameters like different load cycling, switching, working in hot weather and unbalances creates harmonics which creates major reasons for temperature rise of the motors. Due to high peak value of voltage, harmonics can weaken insulation in cables, windings and capacitors and different electronic components. Higher value of harmonics increase the motor current and decrease the power factor which will reduce the life time of the motor and increase the overall rating of all electrical equipments. Harmonics reduction of all the motors in India will save more power. Coating of windings of the motor with nano fillers will reduce the amount of harmonics in the motor. Based on the previous project works, actions were taken to use the enamel filled with various nano fillers for the coating of the windings of the different AC motors. Ball mill method was used to convert the micro particles of Al2O3, SiO2, TiO2, ZrO2 and ZnO into nano particles. SEM, TEM and XRD were used to augment the particle size of the powder. The synthesized nano powders were mixed with the enamel by using ultrasonic vibrator. Then the enamel mixed with the nano fillers was coated to the windings of the several AC motors. Harmonics were measured in terms of various indices like THD, VHD, CHD and DIN by using Harmonic analyzer. There are many other measures and indices to describe power quality, but none is applicable in all cases and in many instances, these indices may hide more than they show. Sometimes power quality indices were used as a basis of comparison and standardization. The efficiency of the motors was increased by 5 – 10 %. The thermal withstanding capacity of the motor was increased by 5º to 15º C. The harmonics of the motors were reduced by 10 – 50%.

Effects of Ondol Sleep Environment on the Thermo-physiological Response of the Human Body (온돌 수면환경이 인체의 온열생리반응에 미치는 영향)

  • Kim, Jung-Sook;Sung, Su-Kwang
    • Fashion & Textile Research Journal
    • /
    • v.1 no.2
    • /
    • pp.173-181
    • /
    • 1999
  • The purpose of this study was to investigate actual sleeping environments in Ondol rooms depending on the season. The experiment was performed on five healthy women. The bedroom environments using Ondol were measured in five cases (three apartments and two houses). The environments in bedroom, bedding temperature, skin temperature and thermal sensation were measured continuously through the seven days for each season in real life. This data of sleeping environments were analyzed in the view of seasonal variations and housing types. Annual average bedroom temperatures: $26.2{\sim}31.0^{\circ}C$ in apartments, $15.7{\sim}33.6^{\circ}C$ in houses. Annual average bedroom humidity: 48.3~82.1% RH in apartments, 64.9~87.0% RH in houses. During sleeping, temperatures of contact surfaces like sheets and under quilts ranged between $30.5^{\circ}C$ and $34.1^{\circ}C$ regardless of season or housing type. Annual average rectal temperature was $36.8^{\circ}C$ with no significant difference in season or housing type. In the point of thermal sensation, neutral temperature of the bedroom was $25.9^{\circ}C$ in apartments and $20.3^{\circ}C$ in houses. It was concluded that in spite of thermal environmental variations according to the seasons, skin, bedding and bedroom temperatures in apartments were better and more stable than those of houses. It is regarded that while houses are brick structured, apartments are steel-frame structured. Due to better insulation and air tightness, apartments were affected less from outdoor temperature and maintained higher room temperature than houses.

  • PDF

A Study on the Design of Prediction Model for Safety Evaluation of Partial Discharge (부분 방전의 안전도 평가를 위한 예측 모델 설계)

  • Lee, Su-Il;Ko, Dae-Sik
    • Journal of Platform Technology
    • /
    • v.8 no.3
    • /
    • pp.10-21
    • /
    • 2020
  • Partial discharge occurs a lot in high-voltage power equipment such as switchgear, transformers, and switch gears. Partial discharge shortens the life of the insulator and causes insulation breakdown, resulting in large-scale damage such as a power outage. There are several types of partial discharge that occur inside the product and the surface. In this paper, we design a predictive model that can predict the pattern and probability of occurrence of partial discharge. In order to analyze the designed model, learning data for each type of partial discharge was collected through the UHF sensor by using a simulator that generates partial discharge. The predictive model designed in this paper was designed based on CNN during deep learning, and the model was verified through learning. To learn about the designed model, 5000 training data were created, and the form of training data was used as input data for the model by pre-processing the 3D raw data input from the UHF sensor as 2D data. As a result of the experiment, it was found that the accuracy of the model designed through learning has an accuracy of 0.9972. It was found that the accuracy of the proposed model was higher in the case of learning by making the data into a two-dimensional image and learning it in the form of a grayscale image.

  • PDF

Analysis of Environmental Design Data for Growing Pleurotus ervngii (큰 느타리버섯 재배사의 환경설계용 자료 분석)

  • Yoon, Yong-Cheol;Suh, Won-Myung;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.95-105
    • /
    • 2005
  • This study was carried out to file up using effect and requirement of energy for environmental design data of Pleurotus eryngii growing houses. Heating and cooling Degree-Hour (D-H) were calculated and compared for. some Pleurotus eryngii growing houses of sandwich-panel (permanent) o. arch-roofed(simple) type structures modified and suggested through field survey and analysis. Also thermal resistance (R-value) was calculated for the heat insulating and covering materials of the permanent and simple-type, which were made of polyurethane or polystyrene panel and $7\~8$ layers heat conservation cover wall. The variations of heating and cooling D-H simulated for Jinju area was nearly linearly proportional to the setting inside temperatures. The variations of cooling D-H was much more sensitive than those of heating D-H. Therefore, it was expected that the variations of required energy in accordance with setting temperature or actual temperature maintained inside of the cultivation house could be estimated and also the estimated results of heating and cooling D-H could be effectively used far the verification of environmental simulation as well as for the calculation of required energy amounts. When the cultivation floor areas are all equal, panel type houses to be constructed by various combinations of materials were found to by far more effective than simple type pipe house in the aspect of energy conservation maintenance except some additional cost invested initially. And also the energy effectiveness of multi-span house compared to single span together with the prediction of energy requirement depending on the level insulated for the wall and roof area could be estimated. Additionally, structural as well as environmental optimizations are expected to be possible by calculating periodical and/or seasonal energy requirements for those various combinations of insulation level and different climate conditions, etc.

Applied Technologies and Effects for the Carbon Zero Office Building (업무용 탄소제로건물의 적용기술 및 효과)

  • Lee, Jae-Bum;Hong, Sung-Chul;Beak, Name-Choon;Choi, Jin-Young;Hong, You-Deog;Lee, Suk-Jo;Lee, Dong-won
    • Journal of Climate Change Research
    • /
    • v.2 no.4
    • /
    • pp.283-295
    • /
    • 2011
  • Many actions against climate change have been taken to reduce greenhouse gases (GHGs) emissions at home and abroad. As of 2007, the GHGs emitted from buildings accounted for about 23 % of Korea's total GHGs emission, which is the second largest GHG reduction potential following industry. In this study, we introduced Carbon Zero Building (CZB), which was constructed by the National Institute of Environmental Research to cut down GHGs from buildings in Korea, and evaluated the main applied technologies, the amount of energy load and reduced energy, and economic values for CZB to provide data that could be a basis in the future construction of this kind of carbon-neutral buildings. A total of 66 technologies were applied for this building in order to achieve carbon zero emissions. Applied technologies include 30 energy consumption reduction technologies, 18 energy efficiency technologies, and 5 eco-friendly technologies. Out of total annual energy load ($123.8kWh/m^2$), about 40% of energy load ($49kWh/m^2$) was reduced by using passive technologies such as super insulation and use of high efficiency equipments and the other 60% ($74.8kWh/m^2$) was reduced by using active technologies such as solar voltaic, solar thermal, and geothermal energy. The construction cost of CZB was 1.4 times higher than ordinary buildings. However, if active technologies are excluded, the construction cost is similar to that of ordinary buildings. It was estimated that we could save annually about 102 million won directly from energy saving and about 2.2 million won indirectly from additional saving by the reduction in GHGs and atmospheric pollutants. In terms of carbon, we could reduce 100 ton of $CO_2$ emissions per year. In our Life Cycle Cost (LCC) analysis, the Break Even Point (BEP) for the additional construction cost was estimated to be around 20.6 years.

A Study on the Prevalence and Risk Factors of Liver Dysfunction among the Workers in Chemical Factories (화학공장 근로자들의 간기능 이상 유병률 및 위험인자에 관한 연구)

  • Cheong, Hae-Kwan;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.103-128
    • /
    • 1997
  • The object of this study is to evaluate the possibility of chemical-induced liver disorder among workers exposed to various chemicals and to classify the the liver function abnormalities by causes and to analyse the risk factors for each liver disorders. A cross-sectional study including questionnaire survey, physical examination, laboratory tests and ultrasonography of liver was conducted on 1,126 workers, 459 workers in a coal chemical plant(company A) and 667 workers in an insulation material manufacturing factory(company B). An industrial hygienist reviewed the chemicals used in both companies and evaluated the work environments to classify the workers by chemical exposure semiquantitatively. The results are as follows: 1. Of 459 workers in company A, 83 workers(18.1%) are classified as nonexposed, group 163(35,5%) as short-term exposure group, 155(33.8%) as intermediately exposed group and 58(12.6%) as long-term exposed group bared on the mean daily exposure to hepatotoxic chemicals evaluated by an industrial hygienist. Of 667 workers in company B, 484(72.6%) workers were classified as nonexposed and 183(35.5%) as exposed group. 2. Workers with SGOT level higher than 40 IU/l were (10.0%) in company A and 77(11.5%) in company 3, and those with SGPT level higher than 35 IU/l were 118(25.7%) in company A and 198(29.7%) in company B. The differences were not significant between companies and between exposure groups(p>0.05). Workers with $\gamma-GT$ level higher than 62 IU/l were 29(6.3%) in company A and 77(11.5%) in company B (p<0.01). The difference between exposure groups was not significant(p>0.05) within companies. Workers with liver function abnormalities(defined as SGOT higher than 40 IU/l or SGPT higher than 35 IU/l) were 338(30.0%) among 1,126 workers. Of 338 workers with live. function abnormalities 139(12.3%) had fatty liver by ultrasonography, 79(7.0%) had alcoholic liver(defined as workers with liver function abnormalities with weekly alcohol consumption greater than 280 g for more than 5 years), 54(4.8%) had hepatitis B, 12(1.1%) had hepatitis C and the other 114(33.7%) was not otherwise classified. Prevalences of alcoholic liver and fatty liver were significantly lower in company A(prevalence ratio 0.24 for alcoholic liver, p<0.001, prevalence ratio 0.76 for fatty liver, p<0.05) but prevalences of liver disorders between exposure groups within companies were not significant(p>0.05). 3. Summary prevalence ratios(SPR) of live. function abnormalities, fatty live. and other liver disorders, adjusted by age and company were not significantly higher in exposed group in any chemicals(p>0.05) but in some chemicals, SPRs were significantly lower. 4. On simple analysis of risk factors for liver function abnormalities, prevalence odds ratio(POR) of those with age between 30 and 39 was 1.54(p<0.01) and those with age ever 40 was 1.51(p<0.01). POR of those with histories of liver disorders and general anesthesia was 1.77(p<0.001) and 4.02 for those with overweight and 6.23 for those with obesity, defined by body mass index(p<0.001). 5. On logistic regression analysis, risk factors of liver function abnormality were fatty liver(POR 2.92 for grade 1, 12.15 for grade 2), presence of hepatitis B surface antigen(POR 3.62) and obesity(POR 5.38 for overweight and 16.52 for obesity). Presence of hepatitis B surface antigen(POR 0.18) was the only preventive facto. of fatty live. Company(POR 0.30) and obesity(POR 2.49 for overweight, 4.52 for obesity) were related to the alcoholic live. Obesity(POR 2.94 for overweight) was the only significant risk factor of hepatitis B and there was no significant risk factor for liver function abnormality not otherwise classified. It is concluded that the evidence of liver disorder related with chemical exposure is not evident in these factories. It is also postulated that fatty liver and alcoholic liver is most common causes of liver function abnormalities among workers and effort for weight control and improvement of life style should be done.

  • PDF