• 제목/요약/키워드: Insulation level

검색결과 342건 처리시간 0.022초

농용 트랙터의 안전캡 내부 소음 감소에 관한 연구(II) -소음 감소 효과- (A Case Study on Inside Noise Reduction of Agricultural Tractor Cab(II) -Noise Reduction-)

  • 유동호;김경욱;최창현
    • Journal of Biosystems Engineering
    • /
    • 제20권2호
    • /
    • pp.127-132
    • /
    • 1995
  • In the first part of this paper, an analysis of the cab noise of a selected agricultural tractor was presented. In this study, using the results of the previous analysis, two passive noise control measures of the sound insulation and absorption were conducted to reduce the noise level inside the cab. These measures of noise control reduced the total noise level by 6.2㏈(A) at the operator position inside the cab. In order to further reduce the cab noise, particularly, of lower frequencies than 630Hz, stiffness and damping of the floor panel should be enforced. It was also suggested that a proper suspension for the cab mounting is necessary to reduce the level of structure-born noises.

  • PDF

Boric acid-Borax-Alum. 계 셀룰로오스 단열재의 훈소특성 연구 (Smouldering Combustibility of Cellulose Insulation Treated with Boric acid-Borax-Alum. Formulation)

  • 김홍
    • 한국안전학회지
    • /
    • 제6권1호
    • /
    • pp.14-25
    • /
    • 1991
  • The smouldering combustibility of cellulose insulation treated with boric acid-borax-alum as combustion retardants are examined by cigarette ignition method and electrical cardrige heater method. The alum to be required at an add on level of at least 12% by weight of cellulose treated with boric acid-borax-alum=2 : 1 : 2 fomulatlon if resistance to smouldering combustion by cigarette ignition is to be achived. The optimum electrical ignition source employed by electrical cartidge heater method was 23.2 watts(80V) power level The effectiveness of Alum as a third combstion retardant are acceptable both smouldering resistance and flame resistance at 18% level of all examined formulation.

  • PDF

포 발사에 따른 쉘터 구조물의 차음 및 구조안전성 연구 (A Study of Sound Insulation and Structure Safety of the Shelter from the Firing of the Large Caliber Gun)

  • 이해석;허동은;박노석;나태흠;장요한;홍준희
    • 한국군사과학기술학회지
    • /
    • 제20권5호
    • /
    • pp.639-646
    • /
    • 2017
  • This paper describes the sound insulation and structural safety of the shelter which may be used for shooters. The noise level of the shelter should be less than 100 dB on the basis of the Industrial Safety and Act, the World Health Organization and the MIL-STD. The sound insulation design was designed for the shelter structure. The designed shelter performance was verified by the real measurement after completing the construction of the shelter. The system was also designed using the finite element method with data of sound pressure measured in the test. Its response was obtained numerically. It is proved that the shelter structure is sufficiently safe considering the calculated maximum stress level with the allowable stress of structural property.

고속철도구간 방음벽 제진재 시험제작 및 성능평가에 관한 연구 (A Study on Sample manufacturing and Performance Evaluation for Vibration Insulation Material of Noise Barrier for High-Speed Railway)

  • 김순철;강정옥;한광섭;전병찬;한종문
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.522-529
    • /
    • 2005
  • The commercial service of KTX from April 1st 2004 has realized that whole country has shrunk into half-day life zone and it opened the times of speed. However, some technical problems unexpected before service have been raised and, among them, the noise generation at train passing was claimed by the residents living nearby the track and it is often publicized by the broadcastings and newspapers. In case where the residential area is close to the track, the installation of noise barrier at trackside is the general measures for noise reduction on bridge section and earthwork section. In case of KTX project, such measures were actually taken without any exception; however, the noise level is still high. In this study, analysis for the reason of higher noise level in spite of which the noise barriers are being installed was carried out, the sample of insulation material effective for noise barrier was manufactured and the performance of the insulation material was evaluated to verify its effectiveness

  • PDF

지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구 (Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault)

  • 김진태;이승용;박상진;차한주;김수열
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

Cost Effective Design of High Voltage Impulse Generator and Modeling in Matlab

  • Javid, Zahid;Li, Ke-Jun;Sun, Kaiqi;Unbreen, Arooj
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1346-1354
    • /
    • 2018
  • Quality of the power system depends upon the reliability of its components such as transformer, transmission lines, insulators, circuit breakers and isolators. The transient voltage due to internal or external reasons may affect the insulation level of the components. The insulation level of these components must be tested against these conditions. Different studies, testing of different electrical components against high voltage impulses and different industrial applications rely on the international manufactures for pulsed power generation and testing, that is quite expensive and large in size. In this paper a model of impulse voltage generator with capacitive load of pin type insulator is studied by simulation method and by an experimental setup. A ten stage high voltage impulse generator (HVIG) is designed and implemented for different applications. In this proposed model, the cost has been reduced by using small and cheap capacitors as an alternative for large and expensive ones while achieving the same effectiveness. Effect of the distributed capacitance in each stage is analyzed to prove the effectiveness of the model. Different values of front and tail resistances have been used to get IEC standard waveforms. Results reveal the effectiveness at reduced cost of the proposed model.

단열 기준에 따른 기둥-보 목조주택의 단열 상세 및 에너지 성능 (Insulation Details and Energy Performance of Post-Beam Timber House for Insulation Standards)

  • 김세종;박주생
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권6호
    • /
    • pp.876-883
    • /
    • 2015
  • 국립산림과학원에서는 한옥의 전통건축기술을 바탕으로 한국형 기둥-보 목조주택인 ?그린 프로젝트를 2006년부터 진행해오고 있다. 최근에는 에너지 절약 기술요소를 적용하여 건물의 에너지성능을 개선하고자 하였다. 본 연구에서는 강화된 단열기준에 따른 기둥-보 목조벽체의 단열상세를 제시하고 그에 따른 건물 에너지 절감 효과를 평가하고자 하였다. 건물외피의 열관류율은 현행법 수준과 저에너지주택인 패시브하우스 수준인 두 단계로 나누었으며 건물에너지 성능을 평가하기 위하여 건물의 기밀성능은 국내 신축 목조주택 수준인 $3.0h^{-1}$과 패시브하우스 수준이 $0.6h^{-1}$ 두 단계로 나누어 열관류율과 기밀성능의 조합에 따라 4가지 경우에 대한 건물에너지 성능 평가가 이루어졌다. 대상건물은 서울에 위치하였으며 에너지 성능은 상용 건물에너지성능 평가 프로그램인 CE3가 사용되었다. 강화된 열관류율에 따라 시뮬레이션을 진행한 결과 연간 난방에너지 요구량은 $14kWh/(m^2{\cdot}a)$ 절감효과를 나타냈다.

Prototype Development for BIM based Thermal Insulation and Condensation Performance Evaluation of Apartment Housings

  • Oh, Hyangok;Cho, Daegu;Jang, Hyang-In;Hong, Soungwook;Lee, Myung Sik
    • Architectural research
    • /
    • 제17권2호
    • /
    • pp.75-81
    • /
    • 2015
  • Insulation and condensation performance evaluation (I&CPE) is an important energy analysis. While considerable amount of data are already represented in a Building Information Model (BIM), the lack of interoperability between BIM modeling and I&CPE programs prevents the simulation process from being efficient and accurate. This study proposes a prototype of a BIM-based I&CPE simulation program, in order to enhance the interoperability between BIM modeling and I&CPE programs. This study discusses the information flow process, defines the required information and its level of detail, develops standardized libraries, and finally proposes a prototype that consists of a data extraction module, conversion module, and performance module. The assurance of interoperability between systems might greatly benefit architects and energy professionals.

인버터 구동에 따른 고압전동기 사고사례와 대책 (Failure Case-Study and Countermeasures of High-Voltage Motor with Inverter Drive System)

  • 최영찬;우명호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 2002
  • Recently, the insulation breakdown accident has been experienced at 6.6kV inverter driving motor. That brought about the reliability degradation of motor driving system.. We need to find the solution with system engineering level. The objectives of this study are developing the appropriate filter for the drive to protect the motor and the Insulation system of motor which Is driven by inverter. We clarify the cause of the deterioration of the inverter driving motor through the analysis of Insulation breakdown accidents.

  • PDF

수화발열량차 및 단열양생 공법을 활용한 매스콘크리트의 현장적용 (Field Application of Mass Concrete Applying Hydration Heat Differential Method and Insulation Curing Method)

  • 한준희;임군수;신세준;전충근;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.227-228
    • /
    • 2023
  • This study is tocompare and analyze the results of hydration heat analysis and on-field measurements using the method with hydration heat difference and insulation curing method for controlling hydration heat in mass concrete. As a result of the analysis, the temperature difference between the center and the surface was predicted very similarly, and the mass concrete surface was controlled to a safe level when evaluating with a temperature crack index, and after being finished, it was confirmed that there was no hydration crack.

  • PDF