• Title/Summary/Keyword: Insulation level

Search Result 341, Processing Time 0.025 seconds

A study on the Prediction of the Road Traffic Noise Distribution around the High-Rise Building (도로교통소음에 대한 고층건물의 외부 소음분포 예측에 관한 연구)

  • Jung, Suk-Hwan;Kim, Dae-Woong;Lim, Tae-Sub;Kim, Byung-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1087-1092
    • /
    • 2006
  • Recently, traffic noise level is rapidly increasing, and it is crowed caused by recently overcrowded and overgrown cities, and increasing traffic volume is emerging as a major factor of disrupting the living and working environment. In this situation, citizens are increasingly complaining about the traffic noise. The noise level of in major cities in Korea is serious and affects on citizens physically and psychologically. Many people live in residential areas around crowed roads in major cities, such as Seoul. Accordingly, the purpose of this study is to predict outside noise distribution of building through survey and simulation to make better sound insulation performance research. The result of this study shows that the traffic noise is influenced from ground 50m and analyzed that form of building and arrangement type must be considered to the level of noise decrease.

  • PDF

Properties of Foamed Concrete According to Types and Concentrations of Foam Agent (기포제 종류 및 희석 농도에 따른 기포 콘크리트의 특성)

  • Kim, Jin-Man;Jeong, Ji-Yong;Hwang, Eui-Hwan;Shin, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • Recently, the government has been working feverously to save energy and reduce greenhouse gas emission by enacting Basic Act on Low Carbon Green Growth at the national level. Improving the insulation performance of building exterior and insulator can reduce the energy in the building sector. This study is about developing light-weight foamed concrete insulation panel that can be applied to buildings to save energy and to find the optimal condition for the development of insulation materials that can save energy by enhancing its physical, kinetic and thermal characteristics. Various experimental factors and conditions were considered in the study such as foam agent types (AES=Alcohol Ethoxy Sulfate, AOS=Alpha-Olefin Sulfonate, VS=Vegetable Soap, FP=Fe-Protein), foam agent dilution concentration (1, 3, 5%), and foam percentage (30, 50, 70%). Experiment results indicated that the surface tension of aqueous solution including foam agent, was lower when AOS was used over other foam agents. FP produced relatively stable foams in 3% or more, which produced unstable foams containing high water content and low surface tension when diluted at low concentration. Depending on foam agent types, compressive strength and thermal conductivity were similar at low density range but showed some differences at high concentration range. In addition, when concentrations of foam agent and foaming ratio increased, pore size increased and open pores are formed. In all types of foam agent, thermal conductivity were excellent, satisfying KS standards. The most outstanding performance for insulation panel was obtained when FP 3% was used.

Comfort Properties of Ski Wear Using Vapor-Permeable Water Repellent Fabrics and Thermal Insulation Battings (투습발수직물과 축열보온섬유를 이용한 스키웨어의 쾌적감)

  • Cho Gil Soo;Choi Jong Myoung;Lee Jung Ju;Lee Sern Woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.2
    • /
    • pp.245-254
    • /
    • 1992
  • The purpose of this study was to evaluate the mechanical thermal resistances and comfort properties of ski wear made with vapor-permeable water repellent (VPWR) fabrics and thermal insulation battings. Four types of experimental clothing were made with the combination of two VPWR fabrics (Hipora-$TM^{\circledR}$, Hipora-$CR^{\circledR}$) and two thermal insulation battings ($Viwarm^{\circledR},\;Airseal^{\circledR}$). Thermal resistances of ski wear were objectly evaluated by thermal manikin experiment ($21{\pm}\;2^{\circ}C,\;50{\pm}5\%$ R.H.,0.25 m/sec air velocity) and thermographic accessment ($2{\pm}2^{\circ}C,\;0\%$ R.H.,0.25 m/sec air velocity, and emissivity level : 1). Garment wear tests of ski wear included the measurement of the microclimate (inner temp. and relative humidity) of the experimental clothing by digital thermohygrometer and subject wear sensation using McNall's thermal comfort ratings. CBo values of experimental clothing 4 (Hipora-$CR^{\circledR}+Airseal^{\circledR}$) and 1 (Hipora-$TM^{\circledR}+Viwarm^{\circledR}$) were significantly higher than those of 2 (Hipora-$TM^{\circledR}+Airseal^{\circledR}$) and 3 (Hipora-$CR^{\circledR}+Viwarm^{\circledR}$). Thermal resistances in the points of breast, back, belly, and loin was significantly higher than those of upper am, fore arm, and shank of measuring points on the thermal manikin. According to the color map of the thermogram, the experimental clothing 4 indicated higher surface temperatures than the others showing more yellowish spots on the surface of clothing. Inner temperature of experimental clothing was not significantly different among the four types of ski wear, but relative humidities of experimental clothing were significantly different. Relative humidities of experimental clothing 1 and 3 showed higher than those of 2 and 4. Relative humidity of experimantal clothing was affected largely by the thermal resis- tance of thermal insulation batting materials. The subject wear sensation of experimental clothing 2 and 4 showed lower humidity than the others. Subject wear sensation was affected more by humidity sensation than by thermal sensation.

  • PDF

Noise Generation Characteristic for Tunnel Construction Equipments (건설장비에 의한 터널작업의 소음환경 실태)

  • Jang, Jae-Kil;Kim, Kab Bae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.9
    • /
    • pp.841-849
    • /
    • 2013
  • Workers engaged in construction works have been exposed to high levels of noise during their work in tunnels. Noise is one of the major health hazards for employees working in construction sites. The aim of this study is to evaluate the noise levels generating from tunneling equipments such as jumbo drills, backhoes, payloaders, shotcrete machines and service cars. Explosion and turbo fan noises were also monitored. A high precision sound level meter was introduced for measuring LAeq, LAFmax, LAFmin and LCpeak noises in 5 tunneling work sites that were located in Seoul, Kyunggi-do and Kangwon-do areas with NATM and shield methods. The highest noise was recorded by explosion(151.9 dB LCpeak) followed by jumbo drills of higher than 110 dB(A) LAeq. Backhoe normally generated 90~110 dB(A) LAeq while breaking work of rock showed additional around 5~15 dB(A). Noise exposure levels for payloader and shotcrete machine scored more than 90 dB(A) which might be a source of noise-induced hearing loss. Additional research in revealing noise levels from construction equipments operating in tunneling works may enhance the protection of workers who exposed to noise primarily at the sites.

Floor Impact Noise Level for Concrete Slab Integrated with Floor Finishing Layers (콘크리트 슬래브와 바닥 상부구조가 일체된 바닥구조의 바닥충격음)

  • Mun, Dae Ho;Oh, Yang Ki;Jeong, Gab Cheol;Park, Hong Gun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.130-140
    • /
    • 2016
  • Floating floor is most commonly used at apartment houses in Korea for thermal insulation and reducing impact noise. But it in proven that the floating floor is not effective for reducing the floor impact noise in low frequency range. In most cases, impact sound pressure level under 63 Hz frequency band were actually increased by the resonance of resilient material, lightweight concrete and the finishing mortar installed on it. In this paper, an integrated floor system consist of 70 mm light weight concrete and 40 mm finishing mortar successively installed on the concrete slab was suggested to avoid the resonance. Integrated floor system increases total flexural stiffness and mass per unit area. The natural frequencies of first and second vibration mode were increased and acceleration response and floor impact sound level was decreased in all measurement range.

Analysis of Heating and Cooling Load Profile According to the Window Retrofit in an Old School Building (노후 학교건물의 창호 교체에 따른 부하분석)

  • Lee, Ye Ji;Kim, Joo Wook;Song, Doo Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.455-462
    • /
    • 2017
  • The purpose of this study is to analyze heating and cooling load variation due to envelope retrofits in an old school building. In a previous study, envelope retrofit of an old school building resulted in annual energy consumption reduction. However, cooling energy consumption increased with the envelope retrofit. This is because of high internal heat generation rates in school buildings and internal heat cannot escape through windows or walls when the envelope's thermal performance improves. To clarify this assumption, thermal performance changes due to envelope retrofits were analyzed by simulation. Results revealed indoor temperature and inner window surface temperature increased with high insulation level of windows. Indoor heat loss through windows by conduction, convection and radiation decreased and resulted in an increase of cooling load in an old school building. From results of this study, energy saving impact of envelope retrofits in an old school building may not be significant because of high internal heat gain level in school buildings. In case of replacing windows in school buildings, local climate and internal heat gain level should be considered.

A New Method for Elimination of Zero-Sequence Voltage in Dual Three-Level Inverter Fed Open-End Winding Induction Motors

  • Geng, Yi-Wen;Wei, Chen-Xi;Chen, Rui-Cheng;Wang, Liang;Xu, Jia-Bin;Hao, Shuang-Cheng
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.67-75
    • /
    • 2017
  • Due to the excessive zero-sequence voltage in dual three-level inverter fed open-end winding induction motor systems, zero-sequence circumfluence which is harmful to switching devices and insulation is then formed when operating in a single DC voltage source supplying mode. Traditionally, it is the mean value instead of instantaneous value of the zero-sequence voltage that is eliminated, through adjusting the durations of the operating vectors. A new strategy is proposed for zero-sequence voltage elimination, which utilizes unified voltage modulation and a decoupled SVPWM strategy to achieve two same-sized equivalent vectors for an angle of $120^{\circ}$, generated by two inverters independently. Both simulation and experimental results have verified its efficiency in the instantaneous value elimination of zero-sequence voltage.

The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation (발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구)

  • Yun, Chang-Yeon;Jeong, Jeong-Ho;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.

An Study on the Sound Attenuation and the Improvement in Hearing Condition of Fire Alarm Device in Apartment Buildings (공동주택 화재 경보음 전달특성과 개선방안 고찰)

  • Lee, Min-Joo;Yoon, Myong-O;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.593-601
    • /
    • 2006
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10 dBA. To give the minimum sound level 60 dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

A Case Study of Degradation Characteristics for Rod-Insulator on Catenary System in Electric Railway (전기철도 전차선로 지지애자의 염해지역 열화특성 사례 연구)

  • Jung, Hosung;Park, Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.263-266
    • /
    • 2019
  • In the Airport Railroad, the Yeongjong Bridge has a length of 4,420 m and connects Yeongjong Island with the mainland of Incheon City. The bridge is a two-level structure, consisting of a six-lane road at the upper level and a combination of a road and railroad at the lower level. The environmental conditions for the electric railway come mainly from the salt injury area and a heavy industry zone, and the maintenance cycles are determined differently depending on these conditions. This study analyzed the deterioration characteristics of long rod insulators produced with a movable ceramic bracket and polymer materials in the Yeongjong Bridge section of the Airport Railway operating in the salt injury area according to the material characteristics. Comparison of the corona measurements when the insulators were cleaned at the same time showed that the polymer insulator had a higher insulation performance than the ceramic insulator.