• 제목/요약/키워드: Insulation effect

검색결과 735건 처리시간 0.031초

한국과 유럽의 신선식품용 EPS박스에 대한 전과정 환경영향평가 (Environmental Impact Assessment of EPS Box for Fresh Food in Korea and Europe)

  • 김수연;;신양재;박현진
    • 한국포장학회지
    • /
    • 제28권3호
    • /
    • pp.201-210
    • /
    • 2022
  • Expanded polystyrene (EPS) is the most commonly used fresh food refrigeration insulation in Korea and Europe. Moreover, as the use of disposable packaging materials has increased significantly along with non-face-to-face delivery services since the COVID-19 crisis, social issues related to waste disposal are also being raised. Therefore, in this study, the life cycle of EPS boxes for fresh food is focused on the factors that have a large difference between incineration and landfill including recycling in Europe and Korea in the disposal process after use, and raw materials and energy in the manufacturing process, which account for a large portion of the environmental impact value. We tried to compare the environmental impact of evaluation. Overall, the raw material production stage, box manufacturing stage, and packaging stage have similar processes in Europe and Korea, but unlike Europe, Korea, which lacks landfills and incineration facilities, has focused on expanding the recycling rate. It was necessary to do an environmental impact assessment. Data affecting the environment were derived based on 2019 and 2020 data for Korea and 2017 and 2020 data for Europe. In order to predict the future environmental impact assessment, assumptions about the disposal rate in 2025 and 2030 were introduced and evaluated. As a result of this study, it was found that the raw material production stage of EPS boxes, which have similar processes in both Korea and Europe, has the greatest effect on the global warming effect of Korean EPS boxes. However, Korea, which has a relatively high recycling rate in the disposal process compared to incineration and landfill, showed better environmental performance than Europe in most impact indicators except freshwater eutrophication. In particular, Korea has increased the overall recycling rate compared to Europe by replacing various recyclable materials such as building materials and sundries with XPS (extruded polystyrene) recycled materials. In conclusion, it was found that increasing the recycling rate rather than incinerating and landfilling EPS boxes for fresh food in the domestic EPS industry has relatively less environmental load compared to Europe.

단열용기의 잠열재 배치에 따른 내부 온도 균일성에 대한 영향 (Effect of Latent Heat Material Placement on Inside Temperature Uniformity of Insulated Transfer Boxes)

  • 지형용;정동열;최석천;김정열
    • 한국포장학회지
    • /
    • 제29권1호
    • /
    • pp.27-33
    • /
    • 2023
  • 본 연구에서는 저온물류 시스템의 단열용기의 온도유지 성능에 대하여 5℃급 저온 LHM을 배치하였을 때 배치구성 조건에 따른 온도특성을 확인하였다. LHM을 단열용기 내부에 배치하였을 때 6면과 5면에 상/하부 배치 비중에 차이를 두고 외기부하에 따른 내부 공기 온도균일도 및 목표 온도 유지시간을 분석하였다. 단열용기 내부 공기는 상부의 상승온도와 이때 발생하는 밀도차에 의한 공기 대류현상이 온도 성층화를 발생시키고, 균일도를 확보하기 위해 LHM의 상부 배치 비중이 하부보다 컸을 때 균일성이 높고 유지 시간이 오래 지속되는 것을 확인하였다. 다만, 상부 배치 비중을 높이기 위해 하부 배치를 제외한 조건에서 높은 균일성을 보이지만 짧은 유지 시간으로 보여 적정조건으로 알맞지 않다. 결과적으로 단열용기의 단열재 대칭구성과 LHM의 동일한 중량을 배치하여 보냉용기를 제작할 경우, LHM의 전면 배치를 바탕으로 하부에 비해 상부 배치 비중을 늘렸을 때 내부 공기 온도의 분포 균일도와 유지시간 성능을 높이는데 효율적인 방안이라고 판단된다. 저온물류 보냉용기 성능분석에 있어, 본 연구를 기반으로 다른 조건의 상변화 온도와 잠열량을 갖는 다양한 저온영역대의 LHM을 적용한 수치해석을 수행하여 성능 예측 결과를 확보할 수 있고 온도 균일도를 위한 단열 및 잠열 복합 구성 이송 용기의 최적 설계조건 수립에 기여할 것으로 기대된다.

입자충전형 이중벽 온실에 관한 연구 (A Study on the Double-Wall Greenhouse Filled with Styrene Pellets)

  • 이석건;이종원;이현우
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.59-67
    • /
    • 1995
  • 자동단열온실시스템을 개발할 목적으로 실험용 온실의 천정과 벽체를 이중벽으로 제작하여 이중벽 내부에 단열입자를 자동으로 충전 회수할 수 있도록 시스템을 구성하여, 입자의 송풍성능, 투광성, 입자의 마모실험, 온실의 단열성능 및 차광효과를 분석한 결과를 요약하면 다음과 같다. 1. 약 2㎥의 입자를 충전 회수하는데 약 1시간 15분이 소요되었으나, 온실의 규모에 적합한 송풍기의 용량, 배기구의 면적, 충전관 및 회수관의 조절로 소요시간을 감소시킬 수 있을 것으로 판단되었다. 2. 단열입자의 회수 직후에 이중벽온실의 투광성을 객관성 있게 평가할 수 있는 10시에서 15시까지의 평균 투광율은 67%로 나타났다. 3. 입자의 충전 및 회수를 직송방식으로 하였을 때, 입자마모율이 연속 5개월 사용시 20%로 나타나, 입자의 충전 및 회수를 간접방식으로 수행하는 것이 타당한 것으로 분석되었다. 4. 겨울철 야간에 단열입자를 회수한 이중벽 온실의 내부온도는 외기온보다 평균 3.4$^{\circ}C$ 높았으나, 입자를 충전한 단열온실의 내부온도는 단열면적비가 73%일때 외기온보다 평균 6.6$^{\circ}C$ 높았고, 단열면적비가 100%일때 외기온보다 평균 13.5$^{\circ}C$ 높게 나타나 단열온실의 야간단열성능이 우수함을 알 수 있었다. 5. 일사가 양호하고 외기온이 높은 주간에 입자를 충전한 단열온실(단열면적비 100%)의 차광성능을 분석한 결과, 외기온의 평균이 36.9$^{\circ}C$일 때 온실내부온도의 평균은 3$0^{\circ}C$로 외기온보다 평균 7$^{\circ}C$ 낮게 나타나 차광효과가 크다는 사실을 알 수 있었다.

  • PDF

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

인산염 피막처리 분말을 사용한 Fe-6.0 wt%Si 합금 압분자심의 자기적 특성 (Magnetic Properties of Fe-6.0 wt%Si Alloy Dust Cores Prepared with Phosphate-coated Powders)

  • 장대호;노태환;김광윤;최광보
    • 한국자기학회지
    • /
    • 제15권5호
    • /
    • pp.270-275
    • /
    • 2005
  • 가스분무법으로 제조한 $35\~180\;{\mu}m$ 크기의 $Fe-6.0wt\%Si$ 합금분말에 대하여 인산염계 절연물질을 피막처리하고 $600\~900^{\circ}C$에서 1시간 동안 열처리한 후 압축성형한 압분자심(분말코아)의 자기적 성질 및 기계적 특성을 조사하였다. 대체적으로 열처리온도가 증가할수록 압축강도가 감소하였으며, 자심손실 또한 낮아졌다. $800^{\circ}C$에서 열처리한 경우 압축성형강도가 15 kgf, 100 kHz에서 실효투자율은 74, 품질계수는 26, 50 Oe의 직류자장 하에서 퍼센트투자율은 78 정도의 값을 나타내었으며, 50 kHz-0.1 T에서 자심손실은 $750\;mW/cm^3$였다. 그리고 투자율-주파수 곡선 상에서의 cut-off 주파수는 거의 200 kHz 이상에 이르는 것으로 나타났다. $Fe-6.0wt\%Si$ 합금 압분자심의 이러한 제반 특성은 인산염 피막의 양호한 전기절연효과와, 고규소농도에 따른 합금의 결정자기이방성 및 포화자기변형의 감소, 전기비저항의 증대 등 기초 물성의 변화에 기인하는 것으로 사료되었다.

계곡산개구리 산란지의 수온 및 음환경 특성 (Water Temperature and Sound Environment Characteristics of Huanren Brown Frog Oviposition Sites)

  • 기경석;김지연;이재윤
    • 한국환경생태학회지
    • /
    • 제30권3호
    • /
    • pp.344-352
    • /
    • 2016
  • 본 연구의 목적은 이른 봄철 계곡에서 번식하는 계곡산개구리 산란지의 수온 및 음환경을 규명하는 것이다. 연구대상지는 한국 중부지역 치악산국립공원의 75개소이었다. 조사기간은 2015년 3월 23일부터 4월 24일까지이었다. 알덩이수와 산란지의 물리적 요인간 상관관계 분석결과 산란지 수온과는 양의 상관관계(p<0.05)를, 산란지 음량과는 음의 상관관계(p<0.05)를 나타내었다. 그러나 면적과 수심은 알덩이수와 상관관계를 나타내지 않았다. 계곡산개구리 산란지와 본류의 수온을 비교한 결과 산란지가 본류보다 평균 $2.2^{\circ}C$ 높았다(p<0.001). 계곡산개구리는 이른 봄철 낮은 온도를 극복하기 위하여 물이 고여 있고, 수심이 10cm 내외로 얕은 곳의 수온이 높은 곳에 산란하고 있었다. 또한 알들을 서로 붙여 낳음으로서 보온효과를 극대화하고 있었다. 계곡산개구리와 산란지의 음량을 본류와 비교한 결과 산란지는 본류보다 6.9dB 조용한 것으로 나타났다(p<0.001). 따라서, 계곡산개구리는 이른 봄철의 낮은 온도, 시끄러운 물소리를 극복하기 위하여 계곡 내에서도 수온이 높고, 조용한 미소서식지를 찾아 산란하는 것으로 판단된다. 본 논문은 양서류 산란지의 음환경 특성을 밝힌 첫번째 논문이라는데서 의의가 있다.

공기주입 및 관행 이중피복온실의 재배환경 및 단열성능 비교 (Comparison of Environmental Conditions and Insulation Effect between Air Inflated and Conventional Double Layer Greenhouse)

  • 메쓰캄카남즈사니카닐란가니자야세카라;나욱호;오우라비압둘하메드바바툰데;이종원;라쉬드아드난;김현태;이현우
    • 생물환경조절학회지
    • /
    • 제27권1호
    • /
    • pp.46-53
    • /
    • 2018
  • 본 연구는 공기주입 이중피복온실과 관행 이중피복온실의 생육환경과 단열성능을 비교하기 위하여 수행하였다. 두 온실의 온도, 상대습도, 포차, 이산화탄소농도, 일사량, 딸기 생산량 및 난방연료소비량을 비교하였다. 공기주입온실이 관행온실보다 야간에 상대습도가 더 높고 포차는 더 낮게 나타나 딸기의 생육에 좋지 않은 환경을 보여주었다. 이산화탄소농도는 공기주입온실이 관행온실보다 더 높게 나타났으며, 이는 공기주입온실이 더 밀폐되어 있어 환기량이 적기 때문인 것으로 판단된다. 관행온실의 광투과율이 77%로 공기주입온실의 72%보다 더 높아 관행온실의 광환경이 더 우수한 것으로 나타났다. 관행온실의 딸기 생산량이 더 높게 나타났으며, 이는 관행온실의 생육환경이 공기주입온실보다 더 우수한 결과로 판단된다. 난방연료는 공기주입온실에서 더 적게 소모되어 공기주입온실의 단열성능이 더 우수한 것으로 나타났다.

Research on Liquefaction Characteristics of SF6 Substitute Gases

  • Yuan, Zhikang;Tu, Youping;Wang, Cong;Qin, Sichen;Chen, Geng
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2545-2552
    • /
    • 2018
  • $SF_6$ has been widely used in high voltage power equipment, such as gas insulated switchgear (GIS) and gas insulated transmission line (GIL), because of its excellent insulation and arc extinguishing performance. However, $SF_6$ faces two environmental problems: greenhouse effect and high liquefaction temperature. Therefore, to find the $SF_6$ substitute gases has become a research hotspot in recent years. In this paper, the liquefaction characteristics of $SF_6$ substitute gases were studied. Peng-Robinson equation of state with the van der Waals mixing rule (PR-vdW model) was used to calculate the dew point temperature of the binary gas mixtures, with $SF_6$, $C_3F_8$, $c-C_4F_8$, $CF_3I$ or $C_4F_7N$ as the insulating gas and $N_2$ or $CO_2$ as the buffer gas. The sequence of the dew point temperatures of the binary gas mixtures under the same pressure and composition ratio was obtained. $SF_6/N_2$ < $SF_6/CO_2$ < $C_3F_8/N_2$ < $C_3F_8/CO_2$ < $CF_3I/N_2$ < $CF_3I/CO_2$ < $c-C_4F_8/N_2$ < $C_4F_7N/N_2$ < $c-C_4F_8/CO_2$ < $C_4F_7N/CO_2$. $SF_6/N_2$ gas mixture showed the best temperature adaptability and $C_4F_7N/CO_2$ gas mixture showed the worst temperature adaptability. Furthermore, the dew point temperatures of the $SF_6$ substitute gases at different pressures and the upper limits of the insulating gas mole fraction at $-30^{\circ}C$, $-20^{\circ}C$ and $-10^{\circ}C$ were obtained. The results would supply sufficient data support for GIS/GIL operators and researchers.

대형 풍력터빈 절연커플링 시험장치 개발 및 평가 (Development and Evaluation for the Insulated Coupling Test Machine of a Large Wind Turbine)

  • 주성하;김동현;오민우;김수현;배준우;강종훈;이형우;김경희
    • 대한기계학회논문집B
    • /
    • 제40권8호
    • /
    • pp.543-556
    • /
    • 2016
  • 본 연구에서는 5 MW 급 대형 풍력터빈 절연커플링의 시험평가 장치를 자체설계 개발하였다. 3 MW 급 대형 풍력터빈용 절연커플링에 대한 공인성능시험평가를 수행하고 시험장치에 대해서는 개발요구도, 장치설계, 기능적 고려사항, 구조진동해석 및 검토 결과를 제시하였다. 본 연구에서 고려한 대형 풍력용 절연커플링 모델과 같이 필라멘트와인딩 공법으로 제작된 두꺼운 유리섬유 복합재 파이프의 경우 shell 요소 기반의 유한요소 해석기법과 두께 효과를 정확하게 모델링 할 수 있는 복합재 적층형 3D solid 모델링 기법의 비교결과를 제시하였다. 또한 다수의 판스프링이 적층된 형태로 제작된 디스크팩 구조에 대한 효과적인 비선형 유한요소 해석기법을 제시하고 시험평가 결과와 비교 검증을 수행하였다.

Discussion of Preliminary Design Review for MIRIS, the Main Payload of STSAT-3

  • Han, Won-Yong;Jin, Ho;Park, Jang-Hyun;Nam, Uk-Won;Yuk, In-Soo;Lee, Sung-Ho;Park, Young-Sik;Park, Sung-Jun;Lee, Dae-Hee;Ree, Chang-H.;Jeong, Woong-Seob;Moon, Bong-Kon;Cha, Sang-Mok;Cho, Seoung-Hyun;Rhee, Seung-Woo;Park, Jong-Oh;Lee, Seung-Heon;Lee, Hyung-Mok;Matsumoto, Toshio
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.27.1-27.1
    • /
    • 2008
  • KASI (Korea Astronomy and Space Science Institute) is developing a compact wide-field survey space telescope system, MIRIS (The Multi-purpose IR Imaging System) to be launched in 2010 as the main payload of the Korea Science and Technology Satellite 3. Through recent System Design Review (SDR) and Preliminary Design Review (PDR), most of the system design concept was reviewed and confirmed. The near IR imaging system adopted short F/2 optics for wide field low resolution observation at wavelength band 0.9~2.0 um minimizing the effect of attitude control system. The mechanical system is composed of a cover, baffle, optics, and detector system using a $256\times256$ Teledyne PICNIC FPA providing a $3.67\times3.67$ degree field of view with a pixel scale of 51.6 arcsec. We designed a support system to minimize heat transfer with Muti-Layer Insulation. The electronics of the MIRIS system is composed of 7 boards including DSP, control, SCIF. Particular attention is being paid to develop mission operation scenario for space observation to minimize IR background radiation from the Earth and Sun. The scientific purpose of MIRIS is to survey the Galactic plane in the emission line of Pa$\alpha$ ($1.88{\mu}m$) and to detect the cosmic infrared background (CIB) radiation. The CIB is being suspected to be originated from the first generation stars of the Universe and we will test this hypothesis by comparing the fluctuations in I (0.9~1.2 um) and H (1.2~2.0 um) bands to search the red shifted Lyman cutoff signature.

  • PDF