• Title/Summary/Keyword: Insulation effect

Search Result 738, Processing Time 0.035 seconds

The Effect of Needle Electrode in the Static Charge Elimination Methodes for Streaming-Electrification Insulating Oil (유동대전된 절연유의 제전방식중 침전극 삽입의 영향 (IV))

  • Chung, K.H.;Lim, H.C.;Kim, Y.W.;Hwang, M.W.;Paek, Y.C.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1202-1204
    • /
    • 1995
  • In this paper, We investigated a charge elimination by using a needle electrode in order to prevent the electrification phenomena of insulating oil flowing by force at the internal transformer. In our experiment, We used Acryle and Teflon as the material of charge reducer and measured each of their streaming current and needle electrode current. As a result of experiment, We can explain that the current of needle electrode increase in proportion to insulation of charge reducer.

  • PDF

An Experimental Study on the Noise Reduction for Toilet Stool Plumbings in Apartment Bathroom (공동주택 욕실의 변기 배수소음 저감에 관한 실험적 연구)

  • Baek, Eun-Sun
    • KIEAE Journal
    • /
    • v.7 no.2
    • /
    • pp.57-62
    • /
    • 2007
  • Recently Among indoor noises plumbing noise from supply and drain water pipe is being pointed out as a annoying noise following to floor impact noise, and it is increasing the rate to point the noise due to the following several reasons: water pressure, vibration by fabricated structures and direct noise propagation from upper floor through ceiling This study aims to analyse the characteristics of toilet stool plumbing noise in apartment bathroom which are generated by crossing plumbings and elbows. And it analyse the effect of noise reduction by soundproofing and insulations which are covered at crossing plumbings. And also analyse the characteristics of noise about a type of elbows, crossing plumbing and result of dB(A). At last it provide a fundamental data for the purpose of reduction of plumbing noise in apartment.

Long-term AC Electrical Treeing Behaviors of Epoxy/Layered Silicate Nanocomposites Prepared by a 3-Roll Mill

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.2
    • /
    • pp.85-88
    • /
    • 2012
  • Studies on the effects of layered silicate content on the AC electrical treeing and breakdown behaviors of epoxy/layered silicate nanocomposites were carried out in needle-plate electrode geometry. Wide-angle X-ray diffraction (WAXD) analysis and transmission electron microscopy (TEM) observation showed that 1 wt% of the multilayered silicate was fully exfoliated into nano-sized monolayers in the epoxy matrix however, over 3 wt% of the silicate was in an intercalated state. When 1 wt% layered silicates were incorporated, an electrical tree was initiated in 439 min and propagated at a speed of 2.3 ${\mu}m$/min after applying 781.4 kV/mm, representing a decreased in starting initiation time by a factor of 11.0 and increase in propagation speed by a factor 8.2 in comparison with neat epoxy resin. These values were in great decline after the layered silicate content was increased to 3wt% which implies that the exfoliated silicate blocked the tree initiation and propagation processes effectively. However the effect was largely decreased in the intercalated state.

Design of Tissue-Transfer Container Using Thermoelectric Element Module

  • Park, Yong Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.66-69
    • /
    • 2017
  • The internal temperature of human-tissue transfers must be steadily maintained regardless of the external environmental changes. An ice pack and dry ice are the coolants for the transfer containers for which heat-insulating materials such as EPP (expended polypeopylene and EPS (expended polystrene) are used; however, changes of the external temperature/pressure and the melting of the coolants that is due to a long carriage result in changes of the internal temperature, and this makes it difficult to maintain the temperature. Accordingly, the thermoelectric element was used to design/manufacture a transfer container to maintain the internal temperature regardless of the external environmental changes. As a result of the measurement of the changes of the internal temperatures of the manufactured thermoelectric-element container and the EPS container over time, the internal temperature of the EPS container was increased, whereas the internal temperature of the thermoelectric-element container was maintained. The temperature of the distilled water that was poured into the containers indicated a pattern identical to that of the internal temperature.

Acoustic Modal Property of a Vehicle Passenger Compartment including Head Liner (헤드라이너를 포함한 승용차의 차실의 음향모드 특성)

  • Kim, Seock-Hyun;Lee, Jin-Woo
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.43-48
    • /
    • 2002
  • Acoustic modes of a vehicle compartment dominate the noise characteristics of the vehicle system in the low frequency range. Vehicle compartments have head liner and air gap of proper thickness to mount a interior lamp, as well as to have a good sound insulation and absorption performance. This study estimates the acoustic modal property of the medium size passenger car by experiment and by finite element analysis and also, investigates the effect of the head liner on the acoustic mode of the passenger compartment to obtain useful information for low noise compartment design.

  • PDF

A Study on the Reclosing Overvoltage in 345 [kV] Transmission Line (345kV 계통 재투입과 전압 해석)

  • Yoon, Jae-Young;Park, Dong-Wook;Whang, Chi-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.166-169
    • /
    • 1990
  • The purpose of the circuit breaker on power system is to disconnect the faulty part from the system and to maintain the integrity of the system. With switching overvoltages are generated. When the system voltages become higher, switching overvoltage is important factor in insulation co-ordination. Since the no-load reclosing overvoltage with inductive source is severe, this paper deals with the reclosing overvoltage and the effect of closing resistor. This reclosing overvoltage of 27-bus model system with and without closing resistor is analyzed by using EMTP (Electro-Magnetic Transients Program) for both deterministic and Stochastic model.

  • PDF

The Study on Development of Performance in Cryogenic Piston Pump (초저온 피스톤 펌프의 성능 향상에 관한 연구)

  • Lee, Jongmin;Lee, Jonggoo;Lee, Kwangju;Lee, Jongtai
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.3
    • /
    • pp.240-246
    • /
    • 2014
  • In order to develop a universal cryogenic piston pump of small size for increasing utilization of liquid hydrogen, dynamic compression performance of piston pump were evaluated and improvements were also discussed for piston rod and piston tip. The cryogenic piston pump has crosshead structure and inclined cup shape piston tip. As the results, it was found that i) insulation of heat flow from piston-rod part is required for stable operation ii) improving the self-clearance adjustment effect of piston tip and reducing piston eccentricity were desirable to promote pumping pressure and operating range.

A Study on Dynamic Stiffness of Multi-layered Damping Materials (완충재의 구성에 따른 동탄성계수 변화에 관한 연구)

  • Im, Jung-Bin;Chung, Jin-Yeon;Kim, Kyoung-Woo;Jeong, Gab-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1149-1152
    • /
    • 2007
  • Many kind of damping materials are generally used on concrete slab in apartment building to reduce floor impact noise level. Lately, multi-layered damping material that is consist of several materials are used to improve the effect of floor impact noise insulation. In this study, dynamic stiffness of multi-layered damping material that is consist of common materials such as expanded polystyrene(EPS), expended polyethylene(EPE), ethylene vinyl acetate(EVA) and polyester was investigated. It was found that dynamic stiffness of multi-layered damping material could be estimated if know value of each layer that compose whole structure. And it was found that dynamic stiffness of whole structure did not change even if change order that build layer.

  • PDF

Effects of IACC and its Variation on Annoyance of Heavy-weight Floor Impact Sounds (중량충격음 어노이언스 반응에 대한 IACC 변화의 영향)

  • Kumar P. Senthil;Sato, Shin-ichi;Jeon Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.626-630
    • /
    • 2006
  • This study investigates the effects of Interaural Cross-correlation(IACC) and its variation on annoyance of the heavy-weight impact sounds. Subjects evaluated the annoyance of the heavy-weight floor impact sounds recorded in rooms of apartments which have different sound insulation treatments; furnished and occupied conditions are characterized by the ACF/IACF factors. A paired comparison test was conducted using the impact sound sources whose IACC and variation of IACC values were different. It was found that IACC is inversely correlated with the scale value(r=-0.62) whereas the variation of IACC is not(r=-0.34). On the contrary, ${\Phi}(0)$ is highly correlated with scale value of annoyance and ${\Phi}(0)$ is need to be controlled as constant to find the effect of IACC on annoyance.

  • PDF

Reducing effect for Hydration Heat of High-Strength Concrete according to Admixture Types and Replacement Ratios (혼화재 종류 및 대체율에 따른 고강도콘크리트의 수화열 저감 효과)

  • 유범재;김용로;최세진;김상윤;김상규;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.409-414
    • /
    • 2001
  • The hydration of cement paste occurs when the cement is mixed with water. During the hydration, hydration heat causes the thermal stress depending on the size of concrete and the cement content. Especially in the high-strength concrete, we must give care to the concrete due to its large cement content. In this study, conduction calorimeter and concrete insulation hydration heat meter were used to investigate the hydration heat characteristics of cement and concrete. To reduce hydration heat of high-strength concrete, several types of replacement of fly-ash and blast-furnace slag powder were used in this experiment.

  • PDF