Analysis of Nocturnal Thermal Insulation Effect of Thermal Curtain in Plastic Greenhouse (야간(夜間)의 온실내(溫室內) 보온(保溫)커텐의 보온효과분석(保溫效果分析))

  • Cho, Yong-Baeg;Koh, Hak-Kyun;Kim, Moon-Ki;Kim, Yong-Hyeon
    • Solar Energy
    • /
    • v.9 no.1
    • /
    • pp.22-29
    • /
    • 1989
  • A simulation model of plastic greenhouse was developed to evaluate the insulation effect of thermal curtain. Change in thermal environment with and without thermal curtain was verified through experiments, which agreed with the predicted values satisfactorily. About 18 to 20% of energy was saved in the plastic greenhouse by employing the P.E. film thermal curtain. Employing P.E. film thermal curtain also raised the temperature of the covering film and inner air by $1^{\circ}C$ and $1.5{\sim}1.8^{\circ}C$, respectively.

  • PDF

A Study of Sound Insulation Effect of Periodically Arranged Circular Rods (주기적 배열을 갖는 원형 봉 집합체의 차음효과해석)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Joo;Kim, Sang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.319-324
    • /
    • 2000
  • Sound insulation effect of periodically arranged circular rods is studied by numerical method (BEM) and model experiment in anechoic room. Five different cylinder groups of diameter from 48 mm to 27 mm are arranged, where each group consists of 5 rows of identical rods and area ratio is kept almost the same as 60%. Comparisons of results by BEM and experiment show the band gap frequency ranges are qualitatively in agreement, while experiments gives higher attenuations. Frequency shifted attenuations (BEM results) by first group (${\phi}$48), third group (${\phi}$34) and fifth group (${\phi}$27) show that attenuation curves are in reasonable agreements for both plane wave and point source.

  • PDF

A Study on the Floor-Specific Characteristics of Road Traffic Noise in Apartment Buildings (공동주택의 층별 도로교통 소음의 전달 특성에 관한 연구)

  • Ham, Jin-Sik
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study is an attempt to understand the floor-specific characteristics of facade road traffic noise in apartment buildings. For this purpose, it sampled a total of seven roadside apartment building complexes: three with no soundproof bar barrier installed at roadside, one with a forest buffer zone, one with a sound-absorbing hill, and two with soundproof barriers. The measured noise level was highest on the 5th floor of apartment buildings with no soundproof barrier, and the upper stories from the 5th floor showed lower-noise measurements in order. For apartment buildings with soundproof barriers, however, the noise level was lower on the 10th floor than the 5th floor. Two apartment building groups--one with a sound-absorbing hill and the other with no soundproof barrier--showed similar measurement results in the floor-specific characteristics of facade road traffic noise. This suggests that such installations have little sound insulation effect. In the apartment building complex with a forest buffer zone around it, a slight sound insulation effect was measured on the lower floors of the buildings.

The effect of particle on insulation Characteristic of $SF_6-N_2$ Mixtures ($SF_6-N_2$ 혼합가스의 절연특성에 미치는 파티클의 영향)

  • Lee, Kon;Lee, Dong-Zoon;Lee, Kang-Soo;Kim, Kyung-Wha;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2383-2385
    • /
    • 1999
  • This paper describes the effect of particles on insulation characteristics of $SF_6-N_2$ mixtures such as breakdown voltages, lift-off voltages and maximum discharge. As a result, the breakdown voltage was increased with the increment of $SF_6$ and the mixture containing 20[%] of $SF_6$ has a breakdown voltage ratio factor better than the other mixtures. The lift-off voltage was nearly constant with all mixtures. Discharge was decreased with the increment of $SF_6$.

  • PDF

The Effect of VCB's Multiple Reignition Surge being Affected due to Circuit Parameters (진공차단기 다중재발호 써지에 미치는 회로 파라메터의 영향)

  • Kim, Jong-Gyeum;Jeong, Jong-Ho;Cho, Hyoun-Gil;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.15-17
    • /
    • 1994
  • As VCB has many advantages which is an excellent interruption capability, compact structure, easy maintenance and light weight, it has been widely used as a load breaker. But steep-fronted surge voltage due to high frequency extinguishing capability in switching has been occurred. If it impinges into induction motor, it acts on the electrical stress, and causes to deteriorate winding insulation. In this research, in order to protect motor insulation from the steep-fronted reignition surge, the occurring condition, the cause of the reignition surge and the influence of circuit parameters which have been an effect on the occurrence of reignition and multiple reignition surge has been also analyzed.

  • PDF

A Study of Characteristic for Space Charge in CV Power Cable When Impressed DC and AC Voltage (직류 및 교류인가시 CV전력 케이블에 미치는 공간전하 특성 연구)

  • Jung, Young-Ill;Lim, Yong-Bae;Kim, Jong-Seo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1960-1962
    • /
    • 2000
  • Polyehtylene[PE] in polymer insulation materials of used power cable have carried out in abundance of experiment and study for electrical conduction. insulation breakdown. dielectric character and so on. When apply to field for power cable to make PE, application of DC withstand test to put in practice for inspection is get to effect accumulated space charge. In this paper, to make use of Pulsed Electro-Acoustic(PEA). It is analysis to take shape space charges under AC and DC voltage, clear up the point at issue for effect of DC withstand test.

  • PDF

A Study on the partial Discharge Characteristics according to the Distribution pattern of voids within LDPE (보이드 분포 형태에 따른 LDPE의 부분 방전 특성 연구)

  • Shin, Doo-Seong;Jeon, Seung-Ik;Lee, Jun-Ho;Yun, Do-Hong;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1081-1084
    • /
    • 1995
  • Internal voids located within an insulation will arise partial discharge that causes local breakdown and even the entire insulation breakdown. For HV apparatuses, it is usual case that several voids are formed within non-uniform electric field condition rather than single void within uniform field, which can be solved analitically. The purpose of this work is to study partial discharge and breakdown characteristics of an insulation according to the distribution pattern of two disc-type voids that are located within non-uniform field. The results from numerical field analysis and experiments show that the electric field within the voids decreases as they are arranged more serially, which accordingly results in the increase of partial discharge inception field(PDIF) much higher than that of single void model. With parallel arranged voids, PDIF is almost the same as that of single void model. On the other hand, AC breakdown strength decreases as voids are arranged more serially, which is a natural result considering the reduction of effective insulation thickness. For parallel voids, this effect cannot he noticed where as they show different pattern compared with single void and serial void models in $\Phi$-Q-N analysis. Considering these results may leads us to the conclusion that, in the evaluation of insulating products through PD test, it is not sufficient to determine only PDIV or existence of PD at predetermined voltage level. We could evaluate more accurately by considering all the available data such as PDIV, PD magnitude, PD occurring phase, number of PD pulses, and etc.

  • PDF

Basic Insulation Characteristics of Conduction-Cooled HTS SMES System (전도냉각 고온초전도 SMES 시스템의 기초절연 특성)

  • Choi Jae-Hyeong;Kwang Dong-Soon;Cheon Hyeon-Gweon;Kim Sang-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.8
    • /
    • pp.404-410
    • /
    • 2006
  • Toward the practical applications, on operation of conduction-cooled HTS SMES at temperatures well below 40[K] should be investigated, in order to take advantage of a greater critical current density of HTS and considerably reduce the size and weight of the system. In order to take advantage of a greater critical current density of high temperature superconducting (HTS) and considerably reduce the size and weight of the system, conduction-cooled HTS superconducting magnetic energy storage (SMES) at temperatures well below 40[K] should be investigated. This work focuses on the breakdown and flashover phenomenology of dielectrics exposed in air and/or vacuum for temperatures ranging from room temperature to cryogenic temperature. Firstly, we summarize the insulation factors of the magnet for the conduction cooled HTS SMES. And Secondly a surface flashover as well as volume breakdown in air and/or vacuum with two kind insulators has been investigated. Finally, we will discuss applications for the HTS SMES including aging studies on model coils exposed in vacuum at cryogenic temperature. The commercial application of many conduction-cooled HTS magnets, however, requires refrigeration at temperatures below 40[K], in order to take advantage of a greater critical current density of HTS and reduce considerably the size and weight of the system. The magnet is driven in vacuum condition. The need to reduce the size and weight of the system has led to the consideration of the vacuum as insulating media. We are studying on the insulation factors of the magnet for HTS SMES. And we experiment the spacer configure effect in the dielectric flashover characteristics. From the results, we confirm that our research established basic information in the insulation design of the magnet.

Development of Improvement Technology of Sound Insulation Performance of Unitex Structure (유니텍스 구조의 차음성능 향상기술 개발)

  • Byeon, Jun-Ho;Lee, Joong-Hyeok;Kim, Seockhyun;Lee, Jae-Joon;Ki, Ho-Cheol
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • Unitex is widely used for the floor structure of urban railway vehicles because it shows good structural safety and heat insulation, has long life, and lowers the cost owing to easy installation. However, in spite of these merits, Unitex has a limit to the sound insulation performance, which is very important in vehicle structure. It shows a sound transmission loss considerably lower than the mass law value, which indicates the sound insulation performance per unit weight. Recently, railway vehicle manufacturers and Unitex supplier have tried to improve the sound insulation performance of Unitex, but meaningful results have not been achieved yet. Through the industry-university collaborative research, we propose structural improvement methods to increase the sound transmission loss by more than 5dB and we then verify the effect by performing experiments.

Electrical and Mechanical Properties of Epoxy/Micro-sized Alumina Composite and the Effect of Nano-sized Alumina on Those Properties

  • Park, Jae-Jun;Shin, Seong-Sik;Yoon, Chan-Young;Lee, Jae-Young;Park, Joo-Eon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.260-263
    • /
    • 2015
  • Epoxy/micro-sized alumina composite was prepared and the effects of alumina content on the electrical and mechanical properties were investigated in order to develop an insulation material for gas insulated switchgear (GIS). Nano-sized alumina (average particle size: 30 μm) was also incorporated into the epoxy/micro-sized alumina composite. An electrical insulation breakdown strength test was carried out in sphere-sphere electrodes and the data were estimated by Weibull statistical analysis. Tensile strength was measured at a crosshead speed of 10 mm/min using a universal testing machine. Alumina content was varied from 0 wt% to 70 wt%.). As micro-sized alumina content increased, insulation breakdown strength increased until 40 wt% alumina content and decreased after that content. The tensile strength of a neat epoxy system was 82.2 MPa and that value for 60 wt% alumina content was 91.8 MPa, which was 111.7% higher than inthe neat epoxy system. The insulation breakdown strength of micro-sized alumina (60 wt%)/nano-sized alumina (1 phr) glycerol diglycidyl ether (GDE) (1 phr) composite was 54.2 MPa, which was 116% higher than the strength of the system without nano-sized alumina.