• Title/Summary/Keyword: Insulation diagnostic

Search Result 111, Processing Time 0.034 seconds

Insulation Aging Diagnostics of Submarine Medium Voltage Power Cables (배전급 해저케이블의 절연열화진단)

  • Mo, Jong-Myung;Yi, Dong-Young;Song, Kwang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.149-152
    • /
    • 2001
  • In this work, we have conducted insulation aging assessment and maintenance for submarine medium voltage power cable systems to discriminate and maintain bad cables economically. We have found that aging status of submarine cable systems are very poor and in progress. We have found that insulation status were improved with the replacement of cable terminations. We have confirmed with the electrical and structural analysis of terminations, that the poor aging status of cables are mainly caused not by the cable insulations but by the aging of cable terminations. From the above results, we have also confirmed that the domestic diagnostic system is successful and convenient for the discrimination and maintenance of the damaged cables economically.

  • PDF

A Study on The Insulation Diagnostic and Life Evaluation for the Pumped Storage Generator/Motor (양수 발전 전동기 고정자 권선 절연진단 및 수명평가에 관한 연구)

  • Park, Jong-Jeong;Kim, Hee-Dong;Lee, Young-Jun;Ju, Young-Ho;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1717-1720
    • /
    • 1998
  • In pumped storage Generator-motor stator windings gradually deteriorates due to mechanist, thermal, electrical stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Since the degration of generator-motor is gradually occurred, regular inspection system is necessary to monitor degrading. The result of this diagnosis is a basic for the maintxnance of generator-motor.

  • PDF

A Study on the Acoustic Detection of Partial Discharges in Insulation Oil (유중 부분방전의 음향검출에 관한 연구)

  • Kil, Gyung-Suk;Kim, Sung-Wook;Park, Dae-Won;Kim, Sun-Jae;Song, Jae-Man
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.

Analysis of Partial Discharge Characteristics at Cryogenic Temperature below 77K (77K 이하 극저온 상에서의 부분방전 특성 분석)

  • Lee, Sang-Hwa;Kim, Bok-Yeol;Shin, Woo-Ju;Lee, Bang-Wook;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1562-1563
    • /
    • 2011
  • Partial discharge measurement is one of the effective diagnostic techniques to predict abnormal high voltage dielectric insulation conditions of the electric equipments. Recently partial discharge diagnostic techniques were also utilized to evaluate the cryogenic dielectric insulation of high temperature superconducting electric equipment in liquid nitrogen. Generally, liquid nitrogen at 77 K is used used as the cryogenic and dielectric media for many high temperature superconducting high voltage applications. When a quench in the superconductor occurs, bubbles are generated which can affect the dielectric properties of the liquid nitrogen. So in order to reduce the bubble formation, subcooled nitrogen was also employed for this purpose. In this work, investigation of partial discharge characteristics of subcooled liquid nitrogen were conducted in order to clarify the retardation of partial discharge initiation voltage according to the different subcooling temperature of liquid nitrogen. And also the relation of partial discharge phenomena and the activities of bubbles were analyzed. It was observed that PD inception voltages shows rather different characteristics according to the decrease of subcooling temperature and the activities of bubbles were strongly influenced by temperature of the subcooled liquid nitrogen.

  • PDF

A Study on the Diagnostic Method for Fault Prevention Of Metal Clad Switchgear Using Electromagnetic Detection Techniques (전자파 측정을 이용한 폐쇄 배전반의 사고예방진단 기법에 관한 연구)

  • 김재철;서인철;김영노;전영재
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.29-37
    • /
    • 2002
  • This paper presents the diagnostic method for fault prevention in metal clad switchgear(MCS) through comparison of signals before and after detecting the partial discharge using electromagnetic detection technique. Electromagnetic waves detected by antennas of the inside and outside of MCS are analyzed and compared by frequency spectrum analysis method which can estimate an insulation abnormality and normality of MCS. As a result of the experiment by the proposed method, we can detect the insulation abnormality as partial discharge in MCS and these results can be applied to preventive diagnosis of MCS.

Space Charge Measurement as a Diagnostic Tool to Monitor Ageing in Polymeric Materials

  • Chen, George
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.235-239
    • /
    • 2006
  • Charge dynamics in polymeric materials after aged under ac electric field using the pulsed electroacoustic (PEA) technique is reported. The emphasis is placed on charge decay. The charge dynamics of the ac aged additive free low density polyethylene (LDPE) samples under dc bias differ from the sample without ac ageing, indicating changes brought in by ac ageing. It is believed that a slow decay rate of charge in the ac aged sample is related to the formation of deep traps in the material. However, chemical analysis by infrared spectroscope (FTIR) and Raman microscope reveals no significant chemical changes taken place in the bulk of the material after ac ageing. Further experiments on irradiated LDPE have revealed a similar behaviour, i.e. the charge decay is slower in irradiated samples than that of fresh sample. The findings presented clearly indicate that space charge measurement can be used as a diagnostic tool to monitor ageing in polymeric materials.

Estimation of Dielectric Strength in High Voltage Motor Stator Windings for Circulating Water Pump (순환수 펌프용 고압전동기 고정자 권선의 절연내력 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik;Park, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1191-1192
    • /
    • 2015
  • To assess the deterioration condition of stator insulation, diagnostic and overpotential tests were performed on two high voltage(HV) motors for circulating water pump (CWP). Following the long term rewinding program, the diagnostic test was performed on two motors during the planning maintenance period. After completing the diagnostic test, overpotential test was done on the stator windings of HV motors. During the overpotential test, the No. 1 and No. 2 of HV motors failed at 8.8 kV and 7.9 kV, respectively. Stator windings of two HV motors had deteriorated significantly.

  • PDF

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

Design of a composite diagnostic DC test apparatus for high voltage power cable (고압전력케이블 현장진단시험용 종합 직류시험설비의 검토)

  • Ryoo, Hee-Suk;Kang, Dong-Sik;Sim, Jong-Tae;Lee, Ho-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2326-2328
    • /
    • 1999
  • Developments of effective and economic diagnostic apparatus for industrial plastic insulated high voltage power cables are in discontented condition still. Some report told that DC high voltage was damaged plastic insulation of a partially aged power cable to lead breakdown easily. But now, we have no alternative tools of DC diagnostic apparatus, and we try to reduce a possibility of hazard DC diagnosis. DC diagnostic apparatus still have many advantages to field cable engineer like low price, portability easy applications and sufficient data. Main hazard of DC diagnosis is excessive hight of applied voltage Recent developments for DC diagnosis use considerably low voltage. But new test methods need special measuring device and manipulator, like high input impedance voltmeter, low leakage current high voltage switches, etc. So that reason, new DC diagnostic devices are normally very expensive and have low efficiency, economically. We try to design a composite test device for 3$\sim$4 newly developed method, have economical benefit th industrial engineer.

  • PDF

A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine (고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구)

  • Oh, Bong-Keun;Kang, Dong-Sik;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF