• Title/Summary/Keyword: Insulation degradation

Search Result 230, Processing Time 0.025 seconds

Development of Insulation Degradation Diagnosis System for Electrical Plant

  • Kim, Yi-Gon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.1
    • /
    • pp.33-37
    • /
    • 2002
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defects. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear. it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a electromagnetic wave and acoustic signal to diagnose an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, we design of the neuro-fuzzy model that diagnoses an electrical equipment and is investigated in this paper. Validity of the new method is asserted by numerical simulation.

Gas detection of transformer oil according to degradation characteristic of insulation material (절연물의열화에 의한 변압기유의 가스분석)

  • Hwang, Kyu-Hyun;Seo, Ho-Joon;Lee, Suck-Woo;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.574-574
    • /
    • 2005
  • To found out the degradation characteristic of transformer insulation, insulation material was depisited into transformer oil and heated. Due to the thermal stress which added to insulation, the density of carbon dioxide which included in transformer oil was mesured by using the gas density detection equipment of gas sensor and air circulation method. As a result, it didn't match with the transformer supervision standard. But it was found that as thermal stress increased, the density of carbon dioxide propertionally increased.

  • PDF

A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock (철도차량 견인전동기의 가속열화수명평가 기술현황)

  • Wang, Jong-Bae;Kim, Ki-Jun;Choi, Young-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF

Study on the Tracking Characteristics Depending on Accelerated Degradation of PVC Insulation Material (PVC 절연재료의 가속열화에 따른 트래킹 특성에 관한 연구)

  • Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.91-98
    • /
    • 2017
  • The present paper is a study on the tracking characteristics depending on accelerated degradation of PVC insulation material. In order to insulation degradation of PVC insulation material, the Arrhenius equation, a type of accelerated degradation test formula, was used to conduct accelerated degradation experiments with experiment samples prepared at the following age equivalents: 0, 10, 20, 30 and 40 years. Afterwards, a tracking experiment was conducted on the accelerated experiment samples as part of the KS C IEC 60112 criteria. When measuring the PVC tracking features according to the accelerated aging, the results showed that when 0.1% of ammonium chloride was added to the PVC insulating material, but no tracking occurred. However, depending on the age equivalent, The results of analyzing the current waveform and voltage waveform of the tracking propagation process showed the age equivalent from 0 years to 40 years displayed a break down in insulation resistance and even the BDB(before dielectric breakdown) sections did not maintain the same functionality of the original material. Based on a criterion of an age equivalent of 0 years, material with an age equivalent of 10 years posed a 1.4 times greater risk, material with an age equivalent of 20 years posed a 2 times greater risk, material with an age equivalent of 30 years posed a 4.6 times greater risk, and material with an age equivalent of 40 years posed a 7 times greater risk.

A Study on the Electrical Properties of Electrical Tree Degradation in XLPE Cable Insulation (XLPE 케이블의 전기트리 열화에 따른 전기적 특성 검토)

  • Gang, Dong-Sik;Seon, Jong-Ho;Lee, Hong-Sik;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.400-405
    • /
    • 2000
  • In order to improve the reliability of XLPE cables, it is necessary to understand the mechanism of electrical and water tree degradation. Especially, electrical tree initiation and propagation are important in XLPE cable insulation. This paper deals with the changes of electrical properties of XLPE cable insulation with electrical tree degradation. To understand the electrical properties of XLPE insulation, specimens were prepared by 22.9kV distribution cable and made in a type of block. Ogura needles having tip radius of 10${\mu}{\textrm}{m}$ were inserted into each block pieces. AC voltages of 8kV, 10kV and 12kV at 60Hz were applied to needle. We investigated the relationship between electrical properties(PD quantity, tan$\delta$ and DC current) and the growth of electrical tree. The electrical properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed.

  • PDF

A Comparative Study on the Non-Destructive Diagnostic Methods of the insulation Oils in Power Transformer (전력용 변압기 절연유희 비파괴 진단 시험법 비교연구)

  • 이준호;이동영;최종갑;김재철;곽희로;권태원;한민구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.8
    • /
    • pp.799-807
    • /
    • 1991
  • The various degradation phenomena, such as the evolution of gases, tan e, moisture content and total acid number in insulation oils of power transformer have been measured and analyzed as a function of aging temperatures and periods. The insulation oils have been degraded at laboratory in the period of 17, 34, and 72 days. We have also extracted the insulation oils from the working power transformers. The dissolved gases (such as CO, CO2, H2, CH4 C2H2---), tane, moisture content and total acid number in laboratory samples and field samples have been measured and characterized. It has been found that gases increase with degradation temperature and tane increases with total acid number while the moisture content does not increase with tane.

  • PDF

A Study on the Evaluation of Reliability and Expected Life for the Insulation System of Traction Motors in Urban Transit E.M.U (철도차량용 견인전동기의 수명예측 및 절연신뢰성 평가 방법에 관한 연구)

  • Wang, Jong-Bae;Kim, Sang-Keol;Lee, Heon-Don;Oh, Hyun-Seok;Kim, Ki-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.449-451
    • /
    • 1999
  • When the traction motor for urban transit E.M.U is driven with VVVF controlled inverter, the insulation degradation factors on the 200 Class insulation system of VPI process are analyzed with considering dielectric, mechanical properties, thermal stability, chemical resistivity and compatibility. A new test method of complex accelerating degradation is proposed to evaluate the insulation reliability and the long-term life including harmonic loss and transient surge stress due to PWM inverter drive.

  • PDF

Analysis of Partial Discharge Signals Using Statistical and Pattern Recognition Technique (통계처리와 패턴 인식 기법에 의한 부분방전 해석)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.12
    • /
    • pp.1231-1234
    • /
    • 2006
  • In this study, we detected electromagnetic waves generated in an enclosed switchgear and applied various statistical methods for detecting signals. We calculated the various statistical factors via the appropriate statistical methods. Further, we used these statistics to recognize the characteristics for each pattern by identifying the partial discharge in each case for normal, proceeding and abnormal states. The characteristics of electromagnetic wave patterns occurred in various states at electric power facilities and were used as an output variable for more efficient diagnosis. In this paper, we confirmed that the pattern of partial discharge signal can be used as one of the factors used to analyze the insulation state and to consider while estimating diagnosis of insulation states by recognizing the signal pattern to intelligence. We will utilize the proposed diagnosis method to determine insulation degradation states.

Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers (전력용 변압기의 열화에 의해 생성된 부산물의 분석)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

Analysis of Degradation Characteristics for Oil-Paper Insulation using Tan Delta Measurement (Tan Delta 측정을 이용한 유침 절연지의 열화특성 분석)

  • Kim, Jeong-Tae;Kim, Woo-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1518-1523
    • /
    • 2016
  • In this study, in order to understand the degradation characteristics of oil-paper insulation for power transformers and OF cables, tan delta was measured using cable model specimens with long-term accelerated thermal and electrical aging. In addition, to find out the degradation level due to the accelerated aging, tensile strengths of aged papers were measured. As a result, tan ${\delta}$ showed the characteristics of slight decrease at the first stage and then increase with the aging time, which could be analyzed due to the evaporation of remaining moisture and the change of aging rate with time. Also, the trend of tensile strengths with aging temperature and time was appeared to be exponentially decreased and by use of these data equivalent calculated lifetimes and accelerated aging factors were derived for each aging temperatures. After then, tan ${\delta}$ was analyzed with the equivalent operating years. For all different aging temperatures, the aged data were very well fit to the equivalent operating years and it is shown that tan ${\delta}$ was increased with the decrease of tensile strength.