A study on insulation characteristics with AC Breakdown Test for Stator Winding of 3.3kV class Induction Motor (절연파괴시험을 통한 3.3kV 유도전동기의 절연특성 연구)

  • Lee, Dong-Geun;Lee, Kwang-Ho;Choi, Kyo-Nam;Kim, Hyun-Il;Kwak, Hee-Jin;Oh, Bong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2118-2122
    • /
    • 2005
  • This test was performed to assess the corelation of insulation deterioration condition with breakdown voltage of the stator winding of 3.3kV class induction motors which have been in service for 10 years after being installed in 1993. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor$({\Delta}tan{\delta})$, maximum partial discharges (Qmax) and AC breakdown test. we evaluated the corelation of insulation diagnostic test with AC breakdown test for stator wilding of high voltage induction motor.

  • PDF

Degradation Properties of Epoxy Resin Used in Indoor (옥내용 에폭시 수지의 열화 특성)

  • 남기동;정중일;연복희;허창수;박영두
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.57-60
    • /
    • 2000
  • In this paper, study on the properties of the thermal degradated epoxy resin which is used in indoor insulation apparatus is performed to investigate the problems of the decreasing insulation characteristics and crack in the indoor insulation apparatus. As a parameter of variation, SEM, contact angle, surface resistivity, relative dielectric constant and weight loss are measured. As the results of the above measurements, the contact angle and surface resistivity of the epoxy resin has increased to 200$^{\circ}C$ in but at the above 200$^{\circ}C$ the values have decreased. The relative dielectric constants the thermal treated samples have increased on with the temperature increase. We find the volatile components of the epoxy resin compound has disappeared during thermal degradation by SEM. The insulation properties of the epoxy resin have increased by the 200$^{\circ}C$ but decreased in the above 200$^{\circ}C$.

  • PDF

An Experimental Study on the Sound Insulation Performance Characteristics due to the Variation of Ceiling Structures - Focused on the Sound-absorbing and Insulation materials - (바닥슬래브 하부 구조의 개선을 통한차음특성 변화에 관한 실험적 연구 - 흡.차음재를 중심으로 -)

  • Kim, Jun-Yup;Ki, No-Gap;Jung, Il-Ho;Jung, Hwan-Wook;Song, Min-Jung;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.506-511
    • /
    • 2000
  • The aim of this study is to suggest a fundamental data to improve the sound insulation performance of floor. To achieve the aim of this study, 8 types of sound-absorbing and sound insulation materials were installed under the slab, and the floor systems were compared to the general floor system which was composed of slab, timber frame, gypsum board and wallpaper.

  • PDF

Electrical Insulation Design of a 154 kV Class HTS Transformer (154 kV급 고온초전도 변압기의 전기절연 설계)

  • Cheon, H.G.;Kwag, D.S.;Choi, J.H.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.53-56
    • /
    • 2007
  • In the response to the demand for electrical energy, much effort was given to develop and commercialize high temperature superconducting (HTS) power equipment has been made around the world. Especially, a HTS transformer is one of the most promising devices. Recently, Korea Polytechnic University and Gyeongsang National University are developing a power distribution and transmission class HTS transformer that is one of the 21st century superconducting frontier projects in Korea. For the development of 154 kV class HTS transformer, the cryogenic insulation technology should be established. We have been analyzed insulation composition and investigated electrical characteristics such as the breakdown of $LN_2$, barrier, kapton films, and the surface flashover of FRP in $LN_2$. Furthermore, we are going to compare with measured each value and apply the value to the most suitable insulating design of the HTS transformer.

A Study on Insulation Characteristics by Thickness of Laminated Polypropylene Paper for an HTS Transmission Cable (송전급 HTS 케이블용 반합성지의 두께에 따른 절연특성 연구)

  • Choi, Jin-Wook;Choi, Jae-Hyeong;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.35-38
    • /
    • 2009
  • The high temperature superconducting(HTS) power cable, as a key component of the next generation power transmission system, operates cost-effectively because of much less transmission loss. Currently, a world-wide research has been undertaken actively. In this research, we designed insulation thickness and investigated thickness effect of laminated polypropylene paper(LPP) which is insulation material of HTS cable in case of AC and impulse breakdown.

A Study on the Tracking Characteristics of Phenolic Resin Insulation Material Due to Accelerated Degradation (가속열화에 따른 페놀수지 절연재료의 트래킹 특성에 관한 연구)

  • Kim, Si-Kuk;Choi, Su-Gil;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.42-49
    • /
    • 2017
  • The present article reports the tracking characteristics of phenolic resin insulation material due to accelerated degradation. For assessing insulation degradation of the phenolic resin insulation material, experiment samples with equivalent years of 0, 10, 20, 30, and 40 years were produced by conducting accelerated degradation experiments using Arrhenius equation. Subsequently, tracking experiments according to KS C IEC 60112 standard were conducted for the experiment samples that were previously subjected to accelerated degradation. According to the measured results for tracking characteristics of phenolic resin subjected to accelerated degradation, upon dropping of 0.1% ammonium chloride, the risks were shown to increase by 1.38 times for the equivalent life of 10 years; 1.45 times for 20 years; 1.62 times for 30 years; and 1.94 times for 40 years based on the equivalent life of 0 year. Upon dropping of 0.01% ammonium chloride, the risks were shown to increase by 1.39 times for the equivalent life of 10 years; 1.52 times for 20 years; 1.99 times for 30 years; and 5.30 times for 40 years. According to the experimental results, the tracking risk was shown to be higher for longer-duration insulation degradation due to aging. In particular, the risk was observed to be greatly increased in the case of the equivalent life of 40 years. Therefore, it is proposed that the occurrence possibility and the risk of electric fires could be minimized through institutional preparation of recommended replacement period by considering risks such as insulation degradation, etc. due to aging.

Life Evaluation of Nano-Composites According to the Addition of MgO (산화마그네슘 첨가에 따른 나노컴퍼지트의 수명평가)

  • Shin, Jong-Yeol;Jeong, In-Bum;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.390-395
    • /
    • 2015
  • Molded insulation materials are widely used from large electric power transformer apparatus to small electrical machinery and apparatus. In this study, by adding MgO with the average particle of several tens nm and the excellent thermal conductivity into molding material, we improved the problem of insulation breakdown strength decrease according to rising temperature in overload or in bad environmental condition. We confirmed the life evaluation by using the insulation breakdown and inverse involution to investigate the electrical characteristics of nano-composites materials. By using a scanning electron microscope, it is confirmed that MgO power with the average particle size of several tens nm is distributed and the filler particles is uniformly distributed in the cross section of specimens. And it is confirmed that the insulation breakdown strength of Virgin specimens is rapidly decreased at the high temperature area. But it is confirmed that the insulation breakdown strength of specimens added MgO slow decreased by thermal properties in the high temperature area improved by the contribution of the heat radiation of MgO and the suppression of tree. The results of life prediction using inverse involution, it is confirmed that the life of nano-composites is improved by contribution of MgO according to the predicted insulation breakdown strength after 10 years of specimens added 5.0 wt% of MgO is increased about 2.9 times at RT, and 4.9 times at $100^{\circ}C$ than Virgin specimen, respectively.

Breakdown, V-t and Degradation Characteristics of Insulation in Liquid Nitrogen for HTS Transformer (고온초전도 변압기를 위한 액체질소 중 절연 파괴, V-t. 열화 특성)

  • Nguyen, Van-Dung;Joung, Jong-Man;Baek, Seung-Myeong;Lee, Chang-Hwa;Suck, Song-Hee;Kim, Sang-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.316-323
    • /
    • 2004
  • HTS transformer is one of the most promising devices to supply enough electric energy for quick increase consumption. However, for practical design of the HTS transformer, it is necessary to establish the research on breakdown, V-t characteristics, degradation, and so on. In this paper, we discussed breakdown characteristics and V-t characteristics of polyimide/L$N_2$ and glass fiber reinforced plastic/$LN_2$ composite insulations. These composite insulations have been used as turn-to-turn and layer-to-layer insulations for HTS transformer respectively, Moreover, we investigated the degradation of these insulation samples after breakdown using microscope and SEM photograph.

The Aging Characteristics of Polymer Electrical Insulation Materials bv UV Radiation and Salt Water Spray (옥외용 고분자 전기절연재료의 염수 및 UV조사에 의한 열화 특성)

  • 최남호;한상일;한상옥;박강식;김종석;박양범
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.221-224
    • /
    • 1997
  • In this study we investigated the acting characteristics of Polymers for electrical insulation by UV radiation and salt water spray treatment. We used the Polymers such as EPDM, SR. PTFE. EVA. We measured contact angle and surface resistance to know the aging characteristic of Polymer surface. And we use SEM to observe the change of the surface shape. Dry flashover voltage test impulse voltage test were carried for the polymer insulator(EVA) . Through this experiment and the analysis we could know the polymers have a good resistance to weathering conditions like as salt spray UV irradiation and mix of them. And we can compare the aging characteristics between Polymers. As a result, we could know that the surface characteristics of PTFE is better than the other. And the degree, electrical characteristics is affected by change of surface shape is not big.

  • PDF

The Insulation Evaluation of N2:O2 Mixture Gas

  • Lee, Sang-Ho;Choi, Eun-Hyeok;Lim, Dong-Young;Park, Kwang-Seo;Kim, Se-Dong;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.7
    • /
    • pp.41-46
    • /
    • 2010
  • With the improvement of industrial society, high quality electrical energy, simplification of operation and maintenance, and ensuring reliability are being required. Also we request an urgent change from $SF_6$ gas to an environment-friendly gas insulation material. In this paper, the experiments of breakdown characteristics by pressure and gap change of $N_2/O_2$ mixture gas through a GIS (Gas Insulated Switchgear) model were described. This paper reviews basic data of the surface discharge characteristics for Teflon resin in not only pure $N_2$, $N_2:O_2$ mixture gas as being focused on environmentally-friendly insulating gas, but also $SF_6$. Also, insulation characteristics by breakdown voltage and surface discharge voltage of $N_2:O_2$ mixture gas in the experimental chamber were studied.