• Title/Summary/Keyword: Insulation characteristics

Search Result 1,267, Processing Time 0.032 seconds

Characteristics of Insulation Resistance of Cable according to Temperature Rise and Over-Current for Process of the Melting Furnace (용해로의 공정상 온도상승 및 과전류에 따른 케이블의 절연저항 특성)

  • Suk Bong Ko;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.22-27
    • /
    • 2024
  • The purpose of this study is to explore the trend in insulation resistance values according to temperature and overcurrent by conducting an investigation on the actual condition and experiments on the electrical wiring during the melting furnace process. In addition, the Arrhenius equation is used to determine whether temperatures in the furnace operating process can be applied to the actual field. In the investigation of the actual condition, the insulation resistance started to decrease seven years after replacement, even though cables in oil pump A were replaced in 2010. Both the experimental and theoretical values of the insulation resistance obtained using the Arrhenius equation decreased with an increase in temperature. Errors in insulation resistance (MΩ) values between tests and the Arrhenius equation ranged from ±2 to ±10, demonstrating a high similarity. Results revealed that when the insulation resistance cannot be measured in a manufacturing workplace (quarterly analysis), it can be estimated by partially applying the Arrhenius equation.

The Flashover Characteristics of Test Electrodes against Clearance of Air Insulation for 765kV Transmission Line (765kV급 송전선로 공기절연거리 설정을 위한 시험전극의 섬락전압 특성)

  • Kim, Y.T.;Kim, Y.B.;Lee, H.H.;Kim, J.M.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1337-1340
    • /
    • 1995
  • For the purpose of rational design of air insulation, it is need to experiment with similar to real shape test object and conform the characterisics. But basic distances of air insulation of transmission line, tower, etc. can be acquired from flashover characteristic of rod-rod, rod-plane electrodes. In this paper, before field test of 765kV transmission line for determination of distances of phase to ground insulation, we execute lightning, switching impulse test with test electrod(rod-rod, rod-plane) against clearances of air insulation. Each tests use up-down method and consist of 30 times flashover test. Flashover data treatment program and air correction program following IEC 60-1(1987) standard were completely builted.

  • PDF

A Study on the Window Design of Classroom Exposed to the Aircraft Noise (항공기소음에 노출된 학교 교실 창호 설계에 관한 연구)

  • Song, Hyuk;Song, Min-Jeong;Park, Hyeon-Ku;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.3
    • /
    • pp.214-223
    • /
    • 2004
  • This study aim to find an appropriate window for classrooms to provide proper sound insulation against aircraft noise and to achieve this goal, measurements were taken of the sound insulation performance of windows with various thicknesses of inner air space and sound absorption materials in the inner air spaces. As a result of this study the improvement of the sound insulation performance of windows(single, double and triple window) was shown through the analysis and the measuring of windows with these characteristics. These results may be applied to the manufacture of window frames and provide basic data for the improvement of the sound insulation performance of windows.

Characteristics of Insulation Diagnostic in Traction Motor Stator Windings (견인전동기 고정자 권선의 절연진단 특성)

  • Kim, Hee-Dong;Kim, Chung-Hyo;Park, Young;Park, Hyun-June
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.336-338
    • /
    • 2006
  • Diagnostic tests are used to evaluate the insulation condition of stator windings in traction motor. These tests included ac current, tan delta and maximum partial discharge. The insulation condition of stator windings was assessed by three test items. The stator windings of traction motor were m good condition. After completing the diagnostic tests, the stator windings of traction motors were subjected to gradually increasing ac voltage, until the insulation punctured. No.5 stator windings failed near rated voltage of 18.9 kV. The breakdown voltage of No.1 stator windings was 13.0. The failure was located m a line-end coil at the exit from the core slot.

  • PDF

A Study on Electrical Properties of Pressboard Insulating Paper (프레스 보드 절연지의 전기물성에 관한 연구)

  • Kim, G.Y.;Eom, S.W.;Ahn, M.S.;Kang, D.P.;Yun, M.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.35-38
    • /
    • 1993
  • Pressboard is used for insulation oil-immersed equipment such as transformer. It's low cost, good electrical properties when immersed in oil, ease of storage and installation, and general reliability have made it virtually a universal choice. This study has examined fabricating specimen and specimen characteristics of pressboard.

  • PDF

Variation of the Sound Insulation Performance of Window in the Apartment House depending on the Sound Source Characteristics (공동주택에서 음원특성에 따른 외부창호 차음성능 변화)

  • Park, Hyeon-Ku;Lee, Ok-Kyun;Han, Dong-Hwa;Song, Hyuk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1735-1740
    • /
    • 2000
  • The aim of this study is to analyze the sound insulation performance of windows depending on the sound source types and to propose the noise control method in the apartment house. The regions where apartment houses are constructed are varied in the dominant noise sources such as aircraft noise, railway noise and road traffic noise. For the experiment, nine noise sources including pink noise were selected and recorded, which was used in the experiment by reproducing. As a result of this study, the sound insulation performance of window was found that when the frequency contents of the noise were high level in all frequency bands the difference of sound insulation performance was negligible, but when the frequency contents were low level at particular frequency band the difference of sound insulation performance was shown very differently.

  • PDF

A Study on the Window Design of School Class Room Exposed to The Aircraft Noise (항공기소음에 노출된 학교 교실 창호 설계에 관한 연구)

  • Song, Hyuk;Song, Min-Jeoung;Park, Hyeun-Gu;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.710-717
    • /
    • 2003
  • This study aim to find an appropriate window for class rooms to provide proper sound insulation against aircraft noise and to achieve this, measurements were taken of the sound insulation performance of windows with varying thicknesses of inner air space and sound absorption materials in the inner air spaces. As a result of (his study the improvement of the sound insulation performance of windows(single , double and triple window) has been shown through the analysis and the measuring of windows with these characteristics. These results may be applied to the manufacture of window frames and provide data lot the improvement of the sound insulation performance of windows.

  • PDF

The Electric Insulation Characteristics of the Insulation Paper and Mini-model Cable in Liquid Nitrogen (액체질소에서 절연지 및 mini-model 케이블의 전기절연 특성)

  • 곽동순;김영석;정종만;김해종;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.224-227
    • /
    • 2003
  • According to the increasing power demands for the power transmission of major cities, HTS power cables which have large current capacity and low power loss will be needed. In this paper we have studied breakdown voltage properties of paper/liquid composite insulating system for HTS cable insulation. And we measured the dielectric loss(tan$\delta$) of mini-model cable. From results, the insulation paper-ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

Technology and Application of Hybrid Insulation Film for Electric Magnet Wire (하이브리드 절연필름의 전동기권선 적용 특성 연구)

  • Han, Se-Won;Han, Dong-Hee;Kang, Dong-Phil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.210-211
    • /
    • 2006
  • This study presents the technology and application of hybrid insulation film for electric magnet wire. In order to make the high efficient motor with high space factor, it is necessary to develop a self-lubrication heat-resistant insulation film that can be used when the space factor 70% or more. A key to achieving high windability is to increase the lubricity and bonding strength of vanish, which for a magnet wire generally determines the mechanical scratches characteristics. Effective ways to reduce scratches include improving insulation film prepared by organic and inorganic hybrid synthesis methods.

  • PDF

The Basic Insulation Design of 60 kV Bushing for Netural Line of 154 kV Class HTS Transformer (154 kV급 고온초전도 변압기의 중성선용 60 kV 부싱의 기초 절연설계)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.32-35
    • /
    • 2008
  • A common problem in many fields of cryogenic power engineering is applying high voltage to cold parts of superconducting apparatus. In many cases, a bushing provides electrical insulation for the conductor which makes the transition from ambient temperature to the cold environment. The 60 kV class cryogenic high voltage bushing for neutral line of the 154 kV / 100MVA high temperature superconducting (HTS) transformer was described. The bushing is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors; in the axial direction, there was a temperature difference from ambient to about 77 K. For the insulation design of cryogenic bushing, electrical insulation characteristics of the GFRP were discussed in this paper.