• Title/Summary/Keyword: Insulation characteristics

Search Result 1,267, Processing Time 0.03 seconds

Optical Current Sensors with Improved Reliability using an Integrated-Optic Reflective Interferometer (반사형 간섭계를 이용하여 신뢰성을 향상시킨 광전류센서)

  • Kim, Sung-Moon;Chu, Woo-Sung;Oh, Min-Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.17-23
    • /
    • 2017
  • Optical current sensors are suitable for operation in high voltage and high current environments such as power plants due to they are not affected by electromagnetic interference and have excellent insulation characteristics. However, as they operate in a harsh environment such as large temperature fluctuation and mechanical vibration, high reliability of the sensor is required. Therefore, many groups have been working on enhancing the reliability. In this work, an integrated optical current sensor incorporating polarization-rotated reflection interferometer is proposed. By integrating various optical components on a single chip, the sensor exhibits enhanced stability as well as the solution for low-cost optical sensors. Using this, we performed the characterization for the actual field application. By using a large power source, the current of 0.3 kA~36 kA was applied to the photosensor and the linear operation characteristics were observed. The error of the sensor was within $0{\pm}.5%$. Even when operating for a long time, the error range of the sensor was kept within $0{\pm}.5%$. In addition, the measurement of the frequency response over the range of 60 Hz to 10 kHz has confirmed that the 3-dB frequency band of the proposed OCT is well over 10 kHz.

Preparation of CeO$_2$ Thin Films as an Insulation Layer and Electrical Properties of Pt/$SrBi_2$$Ta_2$$O_9$/$CeO_24/Si MFISFET (절연층인 CeO$_2$박막의 제조 및 Pt/$SrBi_2$$Ta_2$$O_9$/$CeO_24/Si MFISFET 구조의 전기적 특성)

  • Park, Sang-Sik
    • Korean Journal of Materials Research
    • /
    • v.10 no.12
    • /
    • pp.807-811
    • /
    • 2000
  • CeO$_2$ and SrBi$_2$Ta$_2$O$_{9}$ (SBT) thin films for MFISFET (Metal-ferroelectric-insulator-semiconductor-field effect transistor) were deposited by r.f. sputtering and pulsed laser ablation method, respectively. The effects of sputtering gas ratio(Ar:O$_2$) during deposition for CeO$_2$ films were investigated. The CeO$_2$ thin films deposited on Si(100) substrate at $600^{\circ}C$ exhibited (200) preferred orientation. The preferred orientation, Brain size and surface roughness of films decreased with increasing oxygen to argon gas ratio. The films deposited under the condition of Ar:O$_2$= 1 : 1 showed the best C- V characteristics. The leakage current of films showed the order of 10$^{-7}$ ~10$^{-8}$ A at 100kV/cm. The SBT thin films on CeO$_2$/Si substrate showed dense microstructure of polycrystalline phase. From the C-V characteristics of MFIS structure with SBT film annealed at 80$0^{\circ}C$, the memory window width was 0.9V at 5V The leakage current density of Pt/SBT/CeO$_2$/Si structure annealed at 80$0^{\circ}C$ was 4$\times$10$^{-7}$ /$\textrm{cm}^2$ at 5V.

  • PDF

Study of the Method to Examine the Cause of Damage to a Flat-Type Vinyl Cord (VFF) According to the Type of Energy Source (에너지원의 종류에 따른 비닐평형코드(VFF)의 소손원인 판정기법에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.83-88
    • /
    • 2011
  • This study presented the structure and characteristics of vinyl cords used for wiring electric equipment and appliances and analyzed the photographs of damaged flat-type vinyl cords (VFF, $1.25mm^2$) and the metallic cross-sectional structure of melted conductors. Normal VFFs were made by twisting several strands together and the surface of the conductor was red brown. In addition, from the analysis of the metallic structure of the conductor, it was found that its grains had been elongated. The surface of a VFF damaged by normal flame showed no sheen with carbonized insulation material fused on the conductor surface. In addition, from the analysis of the cross-sectional structure of the melted area, it was found that voids of a certain shape were formed on it but that the cord's own elongation structure could not be checked. The cross-sectional analysis of the melted conductor damaged by the external flame applied to a VFF to which electric current was being applied showed no elongation structure for each cord, and revealed that irregular voids and a columnar structure had grown. The surface of the VFF damaged by overcurrent was uniformly carbonized and the cross-sectional structure analysis of the melted conductor revealed that the dendritic structure had grown. The analysis of the characteristics of the VFF melted by short-circuit showed that even though some part of the surface was contaminated, it showed little sheen and that the area rebounded by melting was round in shape. In addition, the cross-sectional structure analysis using a metallurgical microscope showed the boundary surface and columnar structure and revealed an amorphous structure like normal copper at areas other than the melted conductor.

Study on the Thermal Characteristics of Concrete Using Micro Form Admixture (마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구)

  • Park, Young Shin;Kim, Jung Ho;Jeon, Hyun Kyu;Seo, Chee Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Recently, it is certain that the increase of heating and cooling energy consumption by radical change in climate condition has caused serious problems related to environmental and energy concerns associated with increase of fossil fuel usage and carbon dioxide production as well as global warming. So, various actions to reduce greenhouse gas exhaustion and energy consumption have been prepared by world developed countries. Our government has also been trying to seek energy control methods for houses and buildings by proclaiming political polices on low-carbon green growth and construction and performance standards for environment-friendly housing. The energy consumption by buildings approximately reaches 25% of total korea energy consumption, and the increasing rate of energy consumption by buildings is stiffer than the rate by the other industries. The greatest part in the buildings of the energy consumption is building facade. While lots of research projects for reducing energy consumption of the facade have been conducted, but a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research presents here a study to improve the insulation property of structural concrete formed by micro form admixture (MFA) with experimentally reviewing the physical, mechanical and thermal characteristics of the concrete. As the results of this experiment, in the case of concrete mixed with MFA, slump loss has been improved. As the mixing ratio of MFA increases, the compressive strength is decreased and thermal conductivity is increased. Also it was found that water-cement ratio increases, the compressive strength is decreased and thermal conductivity is increased. but, there was not big influence by the change of fine aggregate ratio.

Mock-up Test of Improved Concrete Binders for Lightweight Foamed concrete (경량기포 콘크리트용 개량분체의 Mock-up 실험평가)

  • Choi, Sung-Yong;Jeong, Kwang-Bok;Kim, Gi-Cheol;Kim, Seong-Soo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.853-856
    • /
    • 2008
  • Lightweight foamed concretes are mainly used in apartment building construction for building room floor insulation, sound proof and height difference adjustment, etc. However, existing lightweight foamed concretes have problems like volume reduction by foam removal and excessive crack occurrence, etc, and for compensation, they developed improved concrete binders for lightweight foamed concrete with special characteristics by adding admixture materials used in concrete manufacturing. Therefore, this study reviewed the possibility of its practical use by analyzing all the engineering characteristics after producing imitation member proposed as actual binders and piling lightweight foamed concrete as improved lightweight foamed concrete binder through prior study, the results are as follows. Plain in which various pulverulent materials are mixed showed about 230mm of flow value, satisfying the target flow value, and at 100mm member, about 4mm of settlement occurred, showing a settlement depth reduction effect double the OPC. On strength, OPC showed highest value, but the three levels all showed strengths above the specified value of KS standard 0.5 grade. From the analysis of drying shrinkage member crack, plain, about 0.1mm, was shown very excellent against drying shrinkage crack.

  • PDF

An Experimental Study on Thermal Conductivity of Controlled Low Strength Materials with Coal Ash (석탄회를 활용한 CLSM의 열전도도에 관한 실험적 연구)

  • Lee, Seung Jun;Lee, Jong Hwi;Cho, Hyun Soo;Chun, Byung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3C
    • /
    • pp.95-104
    • /
    • 2012
  • Due to current interest in creation of urban space and urban landscape, more emphasis has been placed on underground space development. With increasing number of underground power cables and its importance, a study of backfill materials for pipe is now imperative. Backfill materials require outstanding thermal characteristics since breakdown of cable insulation can be caused if heat generated from transmission of underground power cables had not been effectively discharged through backfill materials. Also, coal ash, which are industrial by-products, is being produced in high volume every year. Among them, ponded ash (PA) is not recycled and instead, mostly buried. Therefore in this study, thermal conductivity test based on mixture ratio (PA, ponded ash : FA, fly ash) was performed to evaluate the thermal conductivity characteristics of CLSM (controlled low strength materials) with coal ash. The results indicate that the mixture ratio (PA, ponded ash : FA, fly ash) of 80:20, water contents of 28~30%, and cement contents of 7-11% showed the highest conductivity at 0.796~0.884W/mK and thus, considered optimal in terms of recycling ponded ash (PA) as well as for maximizing utilization as backfill materials for pipe in underground.

The Characteristics of Groundwater and a Field Test for Thermal Insulation of Landfarming of Petroleum Contaminated Soil in Winter Season (유류오염지역의 지하수 수질특성 및 동절기 토양경작법의 온도보전을 위한 현장사례 연구)

  • Cho, Chang-Hwan;Kim, Soon-Heum;An, Jong-Ik;Lee, Yoon-Oh;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.5
    • /
    • pp.7-14
    • /
    • 2013
  • The objectives of this study were to identify the characteristics of groundwater in the petroleum contaminated site and to evaluate the applicability of house-type landfarm facilities heated with briquette stoves in winter season. The six monitoring wells were installed at the site where pH, dissolved oxygen, and temperature were all measured. Also groundwater contaminants, benzene, toluene, ethylbenzene, xylene and total petroleum hydrocarbon, were analyzed twice. House-type two landfarm facilities ($12m{\times}40m{\times}4.8m$) each installed with four briquette stoves were constructed. During four rounds treatment process, VOCs, moisture, temperature were monitored and soil contaminants were analyzed. The pH was 6.37 and considered subacid and DO was measured to be 3.12 mg/L. The temperature of groundwater was measured to be $9.48^{\circ}C$. The groundwater contaminants were detected only in the monitoring wells within the contaminated area or close to it showing that the groundwater contaminated area was similar to the soil contaminated area. During the landfarm process, 73.3% of VOCs concentration in interior gas was decreased and moisture was lowered from 17.7% to 13.4%. In the morning, at 8:00 am, the temperature was decreased showing soil ($5.5^{\circ}C$) > interior ($4.8^{\circ}C$) > exterior ($3.5^{\circ}C$). In the afternoon, at 2:00 pm, the temperature was soil ($8.6^{\circ}C$) < interior ($9.9^{\circ}C$) < exterior ($11.5^{\circ}C$) with solar radiation. The temperature difference between interior and exterior was $0.7^{\circ}C$ in the morning, but it was $1.6^{\circ}C$ in the afternoon. A total of 130 days were taken for four round landfarm processes. Each process was completed within 33 days showing 80% of cleanup efficiency ($1^{st}$ order dissipation rate(k) = 0.1771).

Characteristics of loci on Line-to-Earth Voltage according to Earth Fault in Earthing System for Ships (선박의 접지 시스템에서 지락 고장에 따른 대지 전압 변동 특성)

  • Kim, Jong-Phil;Ryu, Ki-Tak;Lee, Yun-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.487-495
    • /
    • 2021
  • The voltages mainly used in ships are 450 [V], 6.6 [kV], and 11 [kV], and an earthed system is applied to ensure the stability of the power distribution system. In general, low-voltage ships using 450 [V] apply an unearthed system, while high-voltage ships using 6.6 [kV] or 11 [kV] use a high-resistance earthed system. When an earth fault occurs in a ship's power distribution system, the voltage of the healthy phase increases to the line-to-line voltage or higher, which causes an excessive impact on the insulation of the cable. Thus, analyzing this behavior is very important. In this paper, we investigate the characteristics of the line-to-earth voltage variation according to earth faults and a recognition procedure of a faulty phase using the symmetrical coordinate method for a high-resistance earthed system and unearthed system. A mathematical model of the line-to-earth voltage was derived through the symmetric coordinate method, and the ship voltage for simulations was selected as 6.6 [kV] and 450 [V]. A MATLAB simulation proved that this method can determine the highest increase of the line-to-earth voltage, which leads by 120° on the faulty phase, and it accurately judges the faulty phase in both earthed systems.

Analysis of Heating Characteristics of Multi-Layered Insulation Curtain with Silica Aerogel in Greenhouses (실리카 에어로겔을 이용한 다겹보온커튼의 온실 난방 특성 분석)

  • Jin, Byung-Ok;Kim, Hyung-Kweon;Ryou, Young-Sun;Lee, Tae-Seok;Kim, Young-Hwa;Oh, Sung-Sik;Kang, Geum-Choon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.320-325
    • /
    • 2020
  • This study aimed to analyze thermo-keeping and economic feasibility by utilizing silica aerogel, which has been attracting attention as a new material, complementing the disadvantages of the conventional multi-layered thermal screen, and producing and installing multi-layered thermal screen. The multi-layered thermal screen used in the experiment was produced in two combinations using a non-woven fabric containing silica aerogel and measured and compared the temperature and fuel consumption changes due to differences in practice with the multi-layered thermal screen being sold and used on the market. Experimental results show that the temperature and relative humidity changes due to the differences of the multi-layered thermal screens in the single-span greenhouse and the multi-span greenhouse were small but remained almost the same temperature and relative humidity. It is judged that this shows that the multi-layered thermal screen using silica aerogel is not inferior to the conventional multi-layered thermal screen. As a result of a comparative analysis of heating energy, the aerogel-based multi-layered thermal screen reduced fuel consumption by about 15% in the single-span greenhouse and about 20% in the multi-span greenhouse compared to the conventional multi-layered thermal screen. It is clear that heating energy is saved as a greenhouse size and duration increase. It was found that the silica aerogel-based multi-layered screen was more breathable and warmer than the conventional multi-layered thermal screen, but It was found that the multi-layered screen used in the multi-span greenhouse was heavier and stiff compared with the conventional multi-layered thermal screen, indicating less workability and operability. Therefore, improvements were applied to the multi-layered screens used in the single-span greenhouses. It was confirmed that the replacement of internal insulation materials reduced thickness and improved stiffness so that there could be sufficient possibility for farmers to use.

Water Temperature and Sound Environment Characteristics of Huanren Brown Frog Oviposition Sites (계곡산개구리 산란지의 수온 및 음환경 특성)

  • Ki, Kyong-Seok;Gim, Ji-Youn;Lee, Jae-Yoon
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.3
    • /
    • pp.344-352
    • /
    • 2016
  • The goal of this study was to identify the water temperature and sound environment of oviposition sites of the Huanren brown frog (Rana huanrensis), which breeds in valleys in early spring. The study was conducted in Chiak National Park, central Korea, between March 23 and April 24, 2015. Correlation analysis of the physical factors of oviposition sites revealed that the number of egg clutches was positively correlated (p < 0.05) with the water temperature and negatively correlated (p < 0.05) with the sound volume of the oviposition sites. However, no correlation was found between clutch number and the total area or depth of water. The water temperature of the oviposition sites was $2.2^{\circ}C$ higher on average than that of the mainstream (p < 0.001). To avoid the low early spring temperatures, R. huanrensis spawned in sites with accumulated water, in which the depths were less than 10cm and the temperature was relatively high. Further, eggs were spawned in clusters in small spaces to maximize the thermal insulation effect. In terms of noise levels, oviposition sites were found to be 6.9 dB quieter than the mainstream (p<0.001). In conclusion, R. huanrensis was found to spawn in warm, quiet, and small oviposition sites in valleys to avoid low early spring temperatures and loud water noise. This study is significant because it is the first to characterize the sound environment of amphibian oviposition sites.