• Title/Summary/Keyword: Insulation Test

Search Result 923, Processing Time 0.03 seconds

The Relationship between Grain Design and Non-uniform Ablation of Solid Rocket Insulation (추진제 형상과 연소관 단열재 불균일 삭마의 관계)

  • Kim, Jeongjin;Lee, Jungseob;Jin, Jungkun;Lee, Dohyung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.2
    • /
    • pp.28-34
    • /
    • 2020
  • In order to relieve the burden of the rear ablative material, the combustion test of the solid rocket motor with the forward deployed multi-pin grain design was successfully performed twice. However, after disassembling the solid rocket motor, a non-uniform ablation pattern was found in the rear ablative material. Periodic repetition of local and regional ablation was measured precisely. Two-dimensional flow and eddy flow, created by the uneven main-pin flow hitting the rear ablative material, were identified as the cause of non-uniform ablation. In addition. when the rear pins were removed, the possibility of securing the soundness of the rear ablative material was confirmed as the average flow velocity and the standard deviation were lowered.

The Effect of Differences between Gal-Ot and Undyed Clothing and clothing Types on Wear Sensation (갈옷과 흰옷 및 그 의복형태의 차가 착용감에 미치는 영향)

  • 박순자;손원교
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.1
    • /
    • pp.30-41
    • /
    • 1999
  • This study was conducted to verify the advantages of Gal-Ot. Gal-Ot is defined the clothings dyed with persimmon juice. Firstly the physical properties of fabrics were examined. Secondly the wear tests were conducted. The wear tests were performed in climatic chamber controlled 3$0^{\circ}C$ air temperature 50$\pm$5% R.H and 0.2m/s air movement. Four women subjects participated in this experiment and 4 times experiments were performed per one subject. The expeimental schedule was planned following 4 steps that is sedentary posture during 30 minutes-walking the 5。slope treadmill by 70m/min during 20 minutes-sedentary posture during 20 minutes-standing posture on toward the blowing wind during 10 minutes. The results obtained is as folows : The insulation of fabric was increased with dyeing with persimmon juice. The air permeability of fabric was remarkably increased with dyeing with persimmon juice. The mean skin temperatures of subjects were apt to be higher in wearing Gal-Ot than undyed clothing. The clothing micro temperature of subjects were slightly inclined to become lower in wearing Gal-Ot than undyed clothing, The clothing micro humidity was decreasee when: the subjects were gal-Ot than wore undyed clothing, And then it brought about more comfortable on wear sensation. The differences of physiological reactions were not consistent between clothing types except for sweat rate on the back. This result may be attributed the to complex experimental schdules consisted of four steps and to a little difference between open type and close type. However I consider that the clothing type of Gal-Ot is suitable for open type because Gal-Ot is summer wear for blocking the sultry heat.

  • PDF

Equipment for Measuring the Adiabatic Temperature Rise of Concrete by Compensating Heat Loss (열손실량 보정을 통한 콘크리트 단열온도상승량 예측 장치)

  • Jin, Eun-Woong;Kim, Chin-Yong;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.535-542
    • /
    • 2012
  • Adiabatic temperature rise test for predicting heat of hydration in mass concrete is especially inconvenient in the field. In order to overcome the problem, the equipment to effectively and conveniently measure semi-adiabatic temperature change was developed. The main objective of this paper is to propose a new and simple equipment for measuring semi-adiabatic temperature rise by using insulation bottles. In order to predict exact heat loss of concrete using this device, it is required to assume the specific heat loss coefficient of the device by water temperature change inside the experimental device. According to experimental and analytical results, the adiabatic temperature rise does not have significant differences in changes of temperature and humidity of air, as well as initial temperature of water. By comparing adiabatic temperature rise tests, the equipment for measuring semi-adiabatic temperature change can be used to predict the hydration heat of concrete within sufficient accuracy.

SLI, AC Breakdown Voltage Characteristics of $SF_6/CF_4$ Mixtures Gas in Nonuniform Field (불평등전계에서 $SF_6/CF_4$ 혼합 가스의 SLI, AC 절연내력 특성)

  • Hwang, Cheong-Ho;Sung, Heo-Gyung;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.245-251
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field was performed. The experiments were carried out under AC voltage and standard lightning impulse(SLI) voltage. Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltages and standard lighting impulse voltage was applied in a needle-plane. The needle-plane electrode whose gap distance was 3 mm were used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field may be influenced by defects like needle-shaped protrusions. In case of slowly rising SLI voltage and AC voltage it is enhanced by corona-stabilization. This phenomena caused by the ion drift during streamer development and the resulting space-charge is investigated. In non-uniform field under negative SLI voltage the breakdown voltage was increase linearly but under positive SLI voltage the breakdown voltage increase non-linearly. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at AC voltage. $SF_6/CF_4$ mixture has good dielectric strength and arc-extinguishing properties than pure SF6. This paper presents experimental results on breakdown characteristics for various mixtures of $SF_6/CF_4$ at practical pressures. We could make an environment friendly gas insulation material with maintaining dielectric strength by combing $SF_6\;and\;CF_4$ which generates a lower lever of the global warming effect.

Development of HVDC 500kV PPLP MI cable systems in Korea (HVDC 500kV PPLP MI 케이블시스템 개발)

  • Lee, Soo-bong;Cho, Dong-sik;Lee, Tae-ho;Kim, Sung-yun;Lee, Su-kil;Jeon, Seung-ik
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1202-1203
    • /
    • 2015
  • This paper describes the development of HVDC ${\pm}500kV$ polypropylene laminated paper (PPLP) mass-impregnated (MI) type cable system for HVDC transmission lines. As you know, mass-impregnated type cable generally has only insulating layer with the Kraft paper impregnated with a high-viscosity insulating compound. But polypropylene laminated paper is made of a layer of extruded polypropylene (PP) film sandwiched between two layers of Kraft paper. Thanks to PP film and its combination with Kraft paper, PPLP has higher AC, Impulse (Imp.) and DC breakdown (BD) strengths as well as lower dielectric loss than conventional Kraft paper insulation. In addition, Kraft MI cable has a limitation for the maximum conductor temperature as $55^{\circ}C$ But this PPLP MI cable has higher maximum conductor temperature than that of Kraft MI cable due to advantage of oil drainage characteristics. It is the most economic type of cable for HVDC transmission. Also HVDC ${\pm}500kV$ PPLP MI cable system was developed including land joints and outdoor-terminations. In order to prove the mechanical and electrical performances, the type test was carried out according to CIGRE recommendations. A full scale cable system has been tested successfully. And additional load cycle and polarity reversal tests on the cable system showed a higher performance compared with a similar mass impregnated paper cable.

  • PDF

A Study on the Toxicity Analysis of Combustion Gases of Architectural Surface Materials and Architectural Adhesives (건축용 외장재와 접착제 연소가스의 독성분석에 관한 연구)

  • Kim, Won-Jong;Park, Young-Ju;Lee, Hae-Pyeong;Lim, Suk-Hwan;Kim, Jung-In
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.48-52
    • /
    • 2013
  • This study was carried out, using toxicity test apparatus, to analyze toxic gases of heat insulation material and adhesives of composite panels used for the architectural surface material when a fire occurs. The findings of this study show that CO, $CO_2$, HCOH, $CH_2CHCN$ and $NO_x$ were detected from styrofoam, reinforced styrofoam, polyurethane foam and glass fiber, but in the case of the polyurethane foam, HCl and HCN were detected as well. All the architectural adhesives released CO, $CO_2$ and $NO_x$, but HCHO was only detected from the adhesives for styrofoam, wood, tile, windows and doors; $CH_2CHCN$ was only from those for wood and stone; $C_6H_5OH$ was only from those for wood. The toxicity index was also measured for architectural surface material and adhesives. Polyurethane foam showed the highest index, 11.7, and glass fiber was followed as 6.8. Reinforced styrofoam showed 5.7 and styrofoam revealed the least 4.9. In the case of architectural adhesives, the highest ranking was those for stone 7.4, windows and doors 6.1, wood 5.3, tile 3.8, and styrofoam 3.7 were followed, respectively.

Development of high speed coupling for 2MW class wind turbine (2MW급 대형 풍력발전기용 고속커플링 개발)

  • Son, Seung Deok;Lee, Hyoung Woo;Han, Jeong Young;Kim, Yong Won;Kang, Jong Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.262-268
    • /
    • 2014
  • This research introduces the structural design and the validation results of the flexible high speed coupling for 2MW class wind turbine which transmit and cut off torque between gear box and generator. The high speed coupling requires electrical insulation to prevent electrical surface damages on gear box. Therefore glass fiber reinforced plastics is applied to absorb the vibration and deformation of power train and to transmit required torque. Finite element analysis was performed to optimize the thickness and accumulation number of glass fiber reinforced plastics. Torque limiter which cut off the abnormal torque is designed in frictional disc type. The design of the coupling was validated with the performance test of prototype.

Fundamental Tests on Compressive Strength Development and Thermal Conductivity of Cement Pastes Including Fumed Silica (흄드 실리카 첨가에 따른 시멘트 페이스트의 강도발현 및 열전도 특성에 대한 기초 연구)

  • Park, Jong-Beom;Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.413-418
    • /
    • 2018
  • This fundamental study is to examine the significance and limitation of the fumed silica addition to enhance the early compressive strength gain and thermal conduction resistance of cement pastes. The fumed silica content varied from 0% to 1.6% of the cement content by wt% at an interval of 0.4%. Test results showed that the addition of fumed silica is favorable to enhancing the early strength gain of the cement pastes, indicating that 1-day compressive strength corresponded to 45% of the 28-day strength. This high-early strength gain rate is comparable to the trend commonly observed in steam-cured cement concrete. However, the addition of fumed silica little influenced the thermal conduction resistance of cement pastes.

Evaluation of Cracking Strength of Floating Floor System (뜬바닥구조의 균열강도 평가)

  • Lee, Jung-Yoon;Lee, Bum-Sik;Jun, Myoung-Hoon;Kim, Jong-Mun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • This paper reports the test results of the floating floor system used to reduce the floor noise of apartment buildings. Recently, many soft resilient materials placing between the reinforced concrete slab and finishing mortar are used. The resilient material should not only reduce the floor impact sound vibration from the floor but also support the load on the floor. Thus, even if soft resilient materials satisfy the maximum limitation of light-weight impact sound and heavy-weight impact sound, these materials may not support the load on the floor. The experimental program involved conducting sixteen sound insulation floating floor specimens. Three main parameters were considered in the experimental investigation: resilient materials, loading location, and layers of floor. Experimental results indicated that the stiffness of resilient material significantly influenced on the structural behavior of floating floor system. In addition, the deflection of the floating concrete floor loaded at the side or coner of the specimen was greater than that of the floor loaded at the center of the specimen. However, the aerated concrete did not effect on the cracking strength of floating floor system.

The Evaluation of Fire-Resistant Performance of the Non-bearing Steel Wall Using Fire Resistant Glass (내화유리를 적용한 강재 유리벽의 내화성능 평가)

  • Lee, Jae-Sung;Yim, Hyun-Chang;Yang, Seung-Cho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.72-81
    • /
    • 2018
  • Fireproof structures using concrete, built-up panels and dry walls are usually used in walls inside fire compartments. However, demand for glass walls is emerging due to increase in interest in visibility and external appearance. In this study on steel fire resistance walls using insulation glass, fire resistance tests and performance evaluations were conducted on 60 minute fire resistance walls and exterior walls which could be applied to interior fire compartments and 90 minute fire resistance walls which could be applied to curtain walls. According to the tests, the specimens satisfied the required fire resistance performance. The finite element analysis was conducted after the tests to evaluate the fire resistance performance of the glass walls. The analysis results showed that the preliminary evaluation of fire resistance performance would be feasible.