• Title/Summary/Keyword: Insulation Test

Search Result 919, Processing Time 0.025 seconds

Measurement of sound Insulation of small-size windows (소형 창문의 차음성능 측정에 관한 고찰)

  • Kim, Sang-Ryul;Kang, Hyun-Ju;Kim, Jae-Seung;Kim, Hyun-Sil;Kim, Bong-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.942-945
    • /
    • 2006
  • In order to measure the sound transmission loss(STL) of a test specimen such as windows, which is smaller than the test opening, a special partition is built into the test opening and the specimen is placed in that partition. This paper discusses how the measured STL is changed by the partition when a small-size window of high sound insulation is mounted. Theoretical and experimental investigations are carried out to quantify the effect of the filler wall. The results reveal that the smaller the window size is, the higher sound insulation performance of the filler wall is required in order to measure the accurate STL of the specimen. It is found that the insufficient sound insulation of the filler wall leads to the lower measured value of the window's STL.

  • PDF

Test of Insulation of Double Pancake Windings for a 1MVA HTS Transformer (1MVA 고온초전도 변압기용 더블 팬케이크 권선의 절연시험)

  • Kim, Sung-Hoon;Kim, Woo-Seok;Choi, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Hahn, Song-Yop;Song, Hee-Suck;Park, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1015-1017
    • /
    • 2003
  • In a research and development team of high temperature superconducting (HTS) transformer for power distribution, prior to manufacture a single phase 1MVA 22.9 kV/6.6 kV HTS transformer, a 1MVA transformer for insulation test with windings made of copper tapes with the same size as BSCCO-2223 HTS tape was manufactured. The test transformer was composed of both the copper windings of double pancake type and the shell type core of laminated silicon steel plates. The characteristics tests of the test transformer were performed, such as no load test, load test and short test at 77k using liquid nitrogen. Insulation tests, lightning impulse test, power-frequency voltage test and external insulation test, were accomplished also.

  • PDF

Comparative Analysis on Insulation Performance of Traction Motors for Hybrid Vehicles (하이브리드 차량용 견인전동기의 절연성능 비교분석)

  • Choi, Su-Yeon;Park, Chan-Yong;Kim, Sung-Wook;Park, Dae-Won;Kil, Gyung-Suk;Lee, Kang-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.12
    • /
    • pp.1124-1129
    • /
    • 2008
  • The object of this paper is to acquire the data related to insulation evaluation of hybrid vehicle traction motors. We made a comparative analysis on Insulation Resistance (IR), Dielectric Absorption Ratio (DAR), and Polarization Index (PI) of the motor stators. The experiment was carried out according to IEEE Std. 43 and IEC 60085-1 for insulation resistance test standard of rotating machinery. Test voltage of 500 V was applied between a phase and the enclosure. The IR and the DAR of used motors were lower than those of new ones. The DAR and the PI were $0.92{\sim}1.02$ and $0.74{\sim}1.1$, respectively and the result did not meet the recommendation basis 2 for insulation level H. From the experimental results, we could prepare parameters and basis for insulation evaluation of the traction motor stator by the comparative analysis of short-time insulation resistance changes, DAR and PI.

A Study on the Enhancement of the Sound Insulation Performance of Windows through the Laboratory Tests (실험실 실험을 통한 창의 차음성능 개선에 관한 연구)

  • Kim, Sun-Woo;Chung, Jin-Yun;Lee, Ok-Kyun;Jang, Hyun-Choong;Park, Hyeon-Ku;Song, Hyuk
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.307-314
    • /
    • 2001
  • This study aims to provide fundamental data for enhancing the sound insulation performance of windows. For this study, windows composed of various types and thicknesses, were classified into five categories; fixed, single, double, triple and airtight, and then tested. In order to analyze their sound insulation characteristics and performances. test results were rated using methods such as D, STC, Ts and arithmetical mean. It was found that the sound insulation performance of windows is affected due to their type rather than the thickness of the glass. It was also found that when gap between the inner and outer frames was filled with caulking material, the sound transmission loss at high frequency bands was greatly improved. Therefore, the sound insulation performance of windows would be enhanced by minimizing the gap between frames.

  • PDF

The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가)

  • 이병성;송일근;이재봉;한상옥
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

Insulation Design of the Induction Motor for Subway Traction (전동차 견인용 유도전동기 절연 설계)

  • Lee, J.I.;Lee, J.I.;Kim, K.C.;Lee, K.J.;Kim, J.H.;Choi, Y.C.;Park, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.333-335
    • /
    • 1999
  • In this paper, the insulation system of induction motor for subway traction was designed. In order to design the insulation system of induction motor, various types of insulation system were compared, at first, and test method was investigated in order to verify the designed insulation system. The designed insulation system was satisfied economically, technically by experimental test.

  • PDF

Comparative Analysis on Insulation Performance of Traction Motors for a Hybrid Vehicle (하이브리드 차량용 견인전동기의 절연성능 비교분석)

  • Park, Dae-Won;Park, Chan-Yong;Kil, Gyung-Suk;Lee, Kang-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.219-224
    • /
    • 2008
  • The purpose of this paper is to acquire the data related to insulation evaluation of hybrid vehicle traction motors. We carried out a comparative analysis on Insulation Resistance (IR) and Polarization Index (PI) of motor stators according to IEEE Std. 43 and IEC 60085-1 for insulation resistance test standard of rotating machinery. Maximum test voltage which is applied to between a phase and enclosure was set at 500 V. The IRs of the used motors were lower than those of the new ones. The PIs of the used motor were ranges from 0.74 to 1.1 and did not meet the recommendation basis 2 for insulation level H. From the experimental results, we could prepare parameters and basis for insulation evaluation of motor stators by comparative analysis of the IR and the PI.

  • PDF

A Study on the Fire Resistance of Korean Cellulose Insulation (국내 섬유질 단열재의 내화성능에 관한 연구)

  • Kwon, Young-Cheol;Hwang, Jung-Ha;Yu, Hyung-Kyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.10-16
    • /
    • 2008
  • The fire resistance of thermal insulation and interior finishing materials is recently much emphasized after the fire accident at the Icheon Cold Store in January 2008. Three kinds of thermal insulation are used in buildings. They are Organic, Non-organic and cellulosic insulation. Organic insulation such as polystyrene foam board and urethane foam has high thermal resistance but it has no fire resistance. While non-organic insulation such as rockwool and glassfiber has high fire resistance, it has lower thermal resistance than organic insulation. Cellulose insulation is primarily manufactured from recycled newsprint or cardboard using shredders and fiberizers. Despite of its environmental friendliness and high thermal resistivity, its domestic use has not much increased because of the prejudice that paper can easily burn. However, the cellulose insulation as a product is about 80 wt.% cellulosic fiber and 20 wt.% chemicals, most of which are fire retardants such as boric acid and ammonium sulfate. It is required to secure its fire safety for more consumption as a building insulation in Korea. Therefore, this study investigates the fire resistance of Korean cellulose insulation according to the rate of fire retardant and finally presents the optimum rate of fire retardant in cellulose as building insulation. The fire safety test was conducted according to the ASTM C 1485-00. The test results indicate that above 18 wt% of fire retardant is necessary to secure the fire safety of cellulose insulation.

A Study on Measurement Technique of Insulation Resistance for Non-interrupting Inspection Using Non-contact Voltage Phase Detection Technology (비접촉 전압위상 검출 기술을 이용한 무정전 절연저항 측정 방법에 관한 연구)

  • Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Dong-Woo;Lim, Young-Bae;Choi, Dong-Hwan;Kim, Yong-Hyeok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1106-1112
    • /
    • 2018
  • In this paper, measurement techniques are presented to test the performance of insulation without interruption if it is difficult to measure insulation resistance. Especially, non-contact voltage phase detection techniques have been developed that can be applied in environments where it is difficult to find voltage measurement locations such as component receptors. The performance verification of the non-interrupting insulation resistance measuring devices has been tested against existing products using standard calibration equipment and test jigs. The validation confirmed performance within 2 % for direct contact type and within 10 % for non-contact type. In addition, the procedure to make continuous insulation test using the equipment was proposed.

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.