• Title/Summary/Keyword: Insulation Design

Search Result 899, Processing Time 0.024 seconds

External Flow and Cabin Interior Noise Analysis of Hyundai Simple Model by Coupling CAA++ and ACTRAN

  • Kim, Young Nam;Chae, Jun Hee;Jachmot, Jonathan;Jeong, Chan Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.291-291
    • /
    • 2013
  • The interior vehicle noise due to the exterior aerodynamic field is an important topic in the acoustic design of a car. The air flow detached from the A-pillar and impacting the side windows are of particular interest as they are located close to the driver / passenger and provides a lower insulation index than the trimmed car body parts. HMC is interested in the numerical prediction of this aerodynamic noise generated by the car windows with the final objective of improving the products design and reducing this noise. The methodology proposed in this paper relies on two steps: the first step involves the computation of the exterior flow and turbulence induced non-linear acoustic field using the CAA(Computational aeroacoustics) solver CAA++. The second step consists in the computation of the vibro-acoustic transmission through the side window using the finite element vibro-acoustic solver Actran. The internal air cavity including trim component are included in the simulation. In order to validate the numerical process, an experimental set-up has been created based on a generic car shape. The car body includes the windshield and two side windows. The body is made of aluminum and trimmed with porous layers. First, this paper describes the method including the CAA and the vibro-acoustic models, from the boundary conditions to the different components involved, like the windows, the trims and the car cavity is detailed. In a second step, the experimental set-up is described. In the last part, the vibration of the windshield and windows, the total wind noise level results and the relative contributions of the different windows are then presented and compared to measurements. The influence of the flow yaw angle (different wind orientation) is also assessed.

  • PDF

A Study on the Energy and Water Consumption and their Patterns as Vertical Locations of Apartment Housing Units (아파트 단위 세대의 수직 위치 별 에너지 및 물 사용 규모와 패턴에 관한 연구)

  • Song, Dong-Hun;Kim, Kyung-Tae;Lee, Seung-Jun;Shin, Hyun-Ik
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.53-63
    • /
    • 2017
  • The purpose of this study is to present an integrated analysis for energy use and its patterns as vertical locations of the dwelling units in apartment buildings which are located in an urban area and constructed by a renowned contractor. In order to enhance the effectiveness of the method, the original data of electricity, water, and gas bills which directly reflect the energy use are sorted and analyzed into several groups as vertical locations in each building. And also, by use of comparing and contrasting the data on a monthly and yearly basis, the accuracy of analyses for seasonal energy use and its patterns is strengthened. Comparative analyses used in this study describe the results that vertical locations of dwelling units do not have much influence on electricity and water usage, but are closely related with gas usage for a heating season. According to the analysis of gas usage, the units on the ground and right above pilotis need enhancement in the insulations for heating to mitigate energy loss. Also, the analysis for the middle floor units in each group describe the fact that the gas usage of the units on the ground is consumes 1.5 times greater than that of the typical floors. Therefore, enhanced insulation strategies need to be considered against the adverse condition that the heat loss increases as the wall facing the outside air increases or as the wind velocity increases through the pilotis.

A Study on the Plant Nutrients Impregnation Methods and Soil Covering Effects of Wood Chips (목재칩의 식물영양제 함침방법과 토양 피복효과에 관한 연구)

  • Yu Jin Hong;Dae Woo Choi;Kwon Woong Choi;Suejin Park;Seok Un Jo;Hee Jun Park
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.spc
    • /
    • pp.31-38
    • /
    • 2023
  • In this study, in order to develop a method to efficiently inject essential nutrients necessary for plant growth into wood chips, which are simply used as soil covering materials in the agriculture, landscaping and horticultural industries, the atmospheric pressure dipping method and the vacuum pressure impregnating method are used to improve the plant nutrients injectability and impregnation amount were comparatively analyzed. Nutrient ingredients and 8 major heavy metal contents of wood chips injected with nutrients were analyzed, and soil covering effects were examined by covering wood chips injected with nutrients on soil. Comparing the dipping method and the vacuum pressure impregnation method, it took about 48 hours or more to inject 1,500 g or more of the nutrient aqueous solution into 1 kg of wood chips in the dipping method, but the vacuum pressure impregnation method could be impregnated in about 5 minutes. Components of the impregnated nutrients were detected in proportion to the diluted concentration. As a result of covering the wood chips developed in this study on soil, they showed weakly acidic pH, and the heat insulation and moisturizing effects during the winter season were evaluated to be superior to those of uncovered soil. In the future, wood chips impregnated with nutrients are expected to contribute to the more efficient use of waste wood resources and the long-term supply of nutrients essential for plant growth, reducing excessive use of chemical fertilizers and reducing costs.

Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition (3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).

An Experimental Study on the Charring Rate of Solid Sawn Timber Exposed to Fire (화재에 노출된 제재목의 탄화속도에 대한 실험적 연구)

  • Yeo, In-Hwan;Park, Kyung-Hoon;Cho, Kyung-Suk;Min, Byung-Yeol;Yoon, Myung-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.78-84
    • /
    • 2011
  • In this study, we have measured the charring rate of solid sawn timber as a preceding step for develop performance based fire safety design method of wood framed building structures. The follows are the summary of fire test results carried out with $400{\times}400$ mm cross-section Douglas-fir in varied of thickness and grain directions. I) When the timber thickness increase under same dimension, the charring rate decreases gradually. It is seemed the charring layer up on a thickness roles as a insulation, gives combustion delaying time to specimen. 2) The charring rates measured at different depths (10, 20, 30, 40 mm) in timber which varying thickness (20, 40, 80, 120 mm) when exposed maximum 1 hour standard fire increase by 30 mm depth, but decrease at 40 mm. It is seemed the minimum charr layer should be 30 mm for having role of insulation. 3) The charring rate of cross section surface (direction of perpendicular to grain) was more high than that of grain direction. It can be explained by the cracks and gaps from greater charr contraction made more heat flux incident into timber.

Experimental evaluation of fire protection measures for the segment joint of an immersed tunnel (침매터널 세그먼트조인트의 내화 대책에 대한 실험적 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Kim, Heung-Youl;Jo, Bong-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.3
    • /
    • pp.177-197
    • /
    • 2011
  • In this study, a series of fire experiments under $HC_{inc}$ and ISO834 (duration of 4 hour) fire scenarios were carried out for three different types of fire protection measures for the segment joint to evaluate their applicabilities to an immersed tunnel. The experimental results revealed that an expansion joint installed to allow relative movements between concrete element ends in an segment joint is the most vulnerable to a severe fire. For the fire protection measure where the originally designed steel plates at an expansion joint arc replaced by fire-resistant boards, the experiments showed that they cannot achieve good fireproofing performance under both $HC_{inc}$ fire scenario and ISO834 (4 hour) fire scenarios since the installation of fire-resistant boards results in the reduction of the sprayed fire insulation thickness. On the other hand, the application of modified bent steel plates replacing the original steel plates was proved to be very successful in fireproofing of the expansion joint due to more sprayed materials filled in bent steel plate than in the original design concept as well as higher adhesion between the steel plate and the sprayed fire insulation layer.

An Empirical Study of Soundproof wall with Reduced Wind Load (풍하중 저감형 방음판의 실증 연구)

  • Choi, Jin-Gyu;Lee, Chan-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.272-278
    • /
    • 2018
  • Traffic volume has been greatly increasing due to urban development and the improvement of living standards, and many complaints are being raised due to the increasing road noise. As a countermeasure against these problems, highly soundproof walls are installed on the sides of roads. However, the ability to bear wind loads is a major design requirement for soundproof walls, which contributes to the exponential increases in construction costs and restricts the height of the walls. The aim of this study is to improve the performance of soundproof walls and to dramatically reduce wind loads while maintaining excellent price competitiveness. Based on Helmholz's resonator theory, a new concept is proposed for a ventilation-type soundproofing plate that can pass through a fluid like air and reduce noise. A full-scale metal soundproofing plate was produced to satisfy the quality standards of highways by conducting a sound-pressure transmission-loss test, wind tunnel test, and material quality test. To verify the reliability, the wall was manufactured and installed, and the sound insulation effect was examined by measuring the noise over time. In the future, ventilated soundproof walls on roads could create a pleasant living environment due to the high noise-insulation effect.

Design of EMI Reduction of SMPS Using MLCC Filters (MLCC를 이용한 SMPS의 EMI 저감 설계)

  • Choi, Byeong-In;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.97-105
    • /
    • 2020
  • Recently, as the data speed and operating frequencies of Ethernet keeps increasing, electro magnetic interference (EMI) also becomes increasing. The generation of such EMI will cause malfunction of near electronic devices. In this study, EMI filters were applied to reduce the EMI generated by DC-DC SMPS (switching mode power supply), which is the main cause of EMI generation of Ethernet switch. As the EMI filter, MLCCs with excellent withstanding voltage characteristics were used, which had advantages in miniaturization and mass production. Two types of EMI MLCC filters were used, which are X-capacitor and X, Y-capacitor. X-capacitor was composed of 2 MLCCs with 10 nF and 100 nF capacity and 1 Mylar capacitor. Y-capacitor was consisted of 6 MLCCs with a capacity of 27 nF. When only X-capacitor was applied as EMI filter, the conductive EMI field strength exceeded the allowable limit in frequency range of 150 kHz ~ 30 MHz. The radiative EMI also showed high EMI strength and very small allowable margin at the specific frequencies. When the X and Y-capacitors were applied, the conductive EMI was greatly reduced, and the radiation EMI was also found to have sufficient margin. In addition, X, Y-capacitors showed very high insulation resistance and withstanding resistance performances. In conclusion, EMI X, Y-capacitors using MLCCs reduced the EMI noise effectively and showed excellent electrical reliability.

Discussion of Preliminary Design Review for MIRIS, the Main Payload of STSAT-3

  • Han, Won-Yong;Jin, Ho;Park, Jang-Hyun;Nam, Uk-Won;Yuk, In-Soo;Lee, Sung-Ho;Park, Young-Sik;Park, Sung-Jun;Lee, Dae-Hee;Ree, Chang-H.;Jeong, Woong-Seob;Moon, Bong-Kon;Cha, Sang-Mok;Cho, Seoung-Hyun;Rhee, Seung-Woo;Park, Jong-Oh;Lee, Seung-Heon;Lee, Hyung-Mok;Matsumoto, Toshio
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.27.1-27.1
    • /
    • 2008
  • KASI (Korea Astronomy and Space Science Institute) is developing a compact wide-field survey space telescope system, MIRIS (The Multi-purpose IR Imaging System) to be launched in 2010 as the main payload of the Korea Science and Technology Satellite 3. Through recent System Design Review (SDR) and Preliminary Design Review (PDR), most of the system design concept was reviewed and confirmed. The near IR imaging system adopted short F/2 optics for wide field low resolution observation at wavelength band 0.9~2.0 um minimizing the effect of attitude control system. The mechanical system is composed of a cover, baffle, optics, and detector system using a $256\times256$ Teledyne PICNIC FPA providing a $3.67\times3.67$ degree field of view with a pixel scale of 51.6 arcsec. We designed a support system to minimize heat transfer with Muti-Layer Insulation. The electronics of the MIRIS system is composed of 7 boards including DSP, control, SCIF. Particular attention is being paid to develop mission operation scenario for space observation to minimize IR background radiation from the Earth and Sun. The scientific purpose of MIRIS is to survey the Galactic plane in the emission line of Pa$\alpha$ ($1.88{\mu}m$) and to detect the cosmic infrared background (CIB) radiation. The CIB is being suspected to be originated from the first generation stars of the Universe and we will test this hypothesis by comparing the fluctuations in I (0.9~1.2 um) and H (1.2~2.0 um) bands to search the red shifted Lyman cutoff signature.

  • PDF

A Study on the Standard Drawings of Seoul Middle School Architecture in 1975 (1975년 서울시 중학교 표준설계도에 관한 연구)

  • Lee, Jeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2497-2504
    • /
    • 2013
  • This study aims to analyze the 'Standard Drawings for School Facilities' issued by Seoul Education Committee in 1975 because it is the early example for middle school architecture. The results of this study are summarized as follows 1) In general trend of single-corridor type block plan, there are also changes in floor plan like no-corridor type block plan, $9.9{\times}6.6m$ classroom unit for the better daylight condition, built-in storage for students. 2) As for elevation design, it is characterized as daylight-oriented, functional exterior for without making full use of design elements. 3) Standardized dimensions are used as a rule in the height of story, ceiling, window sill and etc. Transitional characteristics of the early RC school architecture are found in exposed ceiling, incomplete insulation structure and mixed use of wood framed floor of earlier type. 4) Contrast to main school building, gymnasium shows the intend to express the symbolism of school architecture with diverse elevation design elements and the plasticity of building mass. 5) Separated plan of toilet and night-duty building also show the transitional characteristics. As conclusion, though showing the stereotyped school architecture, on the other hand, 'Standard Drawings for School Facilities' (1975) makes it possible to see the way of coping with the demands for school architecture in that time and the transition of school architecture. This is the main value of it as the material for the studies related to the history of educational facilities.