피뢰기 적용에 따른 다양한 배전계통의 뇌과전압 변화특성 (Lightning Overvoltage Characteristics in Distribution System with Arrester Application)

  • 김상국;정채균;이종범;하동혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.355-357
    • /
    • 2002
  • Distribution lines are spanned on a much large area as compared to transmission lines, and therefore, are more often susceptible to lightning strokes. The selection of the proper value of basic insulation level(BIL), for particular insolation components of distribution structures in specific, is very important. Lightning strikes has current risetimes ranging from 0.1 to several $\mu s$ and can produce transient overvoltages substantially greater than the BIL of many distribution systems in spite of lightning arresters. This paper describes lightning overvoltage of a 22.9kV distribution system due to lightning strike. This study will provide the information on insulation coordination studies to adopt BIL.

  • PDF

직격뢰 침입시 배전계통에서 선로 및 기기의 절연설계 (Insulation Design of Line and Equipment in Distribution Systems in Case of the Stroke of Direct Lightning Surge)

  • 정채균;김상국;이종범;하동혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.449-451
    • /
    • 2003
  • This paper examines the insulation coordination scheme of line and equipment in distribution system when the direct lightning surge strikes. The BIL that is applied in distribution system is not properly considered the performance and operation of arresters. Because of that, the high BIL is being used at partial system. This paper variously analyse the lightning overvoltage of line and equipment with earth of overhead grounding wire and installation types of arrester. Form these result, authors examine the rationality of BIL.

  • PDF

345kV 승압용 변전소의 뇌격에 의한 이상전압 해석 (Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer)

  • 조만영;신호전;허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.

피뢰기에 의한 지중배전계통의 써어지 보호 (Surge Protection of Underground Distribution Systems by Surge Arrester Application)

  • 이용한;정동학;정동원;임용혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.176-179
    • /
    • 1992
  • This paper presents results of typical sutdy on lightning overvoltages of underground distribution systems and discusses effective insulation coordination schemes. Typical lightning current and system parameters are used to analyze lightning overvoltage distribution on underground distribution systems by EMTP (Electro-Magnetic Transients Program).

  • PDF

지중송전계통에서 OF케이블의 교량 첨가시 모델 수립 및 해석 (Analysis and Model Establishment of OF Cable Underneath a Bridge on Underground Power Cable Systems)

  • 이현석;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2245-2246
    • /
    • 2008
  • This paper analyses crossbonded cable system underneath a bridge. The simulation is performed under various system configuration such as cable length, iron frame size, lightning surge. The simulation models are established by EMTP/ATPDRraw. In this paper, the crossboneded cable system underneath a bridge is also analyzed for insulation coordination of iron frame and cables.

  • PDF

경량간막이 벽체의 차음특성에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Characteristics of Partition Walls)

  • 김선우;이태강;유창남
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.466-472
    • /
    • 1997
  • This paper aims to investigate the characteristics of partition walls which are lightweighted, such as dry walls of gypsum boards. These partition walls are prospected to be new ones to cope with M.C.(Modular Coordination), flexibility, non-bearing system, substitution to masonryworks. Ten kinds of partition walls are varied with core materials and depth, constructions. Acoustic characteristics of these partitions, transmisson loss, are tested in reverberation chambers.

  • PDF

345kV GIS 변전소 뇌써지 해석 (Analysis of lightning surge on the 345kV Gas Insulated Substation)

  • 김재관;이종범;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.561-563
    • /
    • 2003
  • This paper deals with simulation of lightning overvoltage generated by back flashover entering 345[kV] Gas Insulated Substation. In order to protect the substation equipment against lightning surge, insulation coordination is performed with the lightning arrester. This paper suggests optimal location of lightning arrester using the EMTP/ATPDraw to mere economically and effectively reduce the lightning surge incoming overhead lines.

  • PDF

VSC MMC HVDC System의 절연설계 (Insulation Coordination of VSC HVDC based on MMC topology)

  • 김현민;김희수;조해송;김찬기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.280-281
    • /
    • 2020
  • 본 논문은 MMC 기반의 전압형 HVDC System의 절연설계에 대한 내용을 담고 있다. 절연설계 시 필요한 Surge Arrester 전압결정, 이격거리, 연면거리에 대해 DC측과 AC측을 비교하고 그에 따른 계산 방법에 관한 내용을 기술한다.

  • PDF

직류 비접지계통에서 절연저항측정장치(IMD)를 이용한 사고검출 알고리즘 (Algorithm of Detecting Ground Fault by Using Insulation Monitoring Device(IMD) in Ungrounded DC System)

  • 김기영;이후동;태동현;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.528-535
    • /
    • 2020
  • 최근 신재생에너지 및 분산전원의 급속한 보급과 직류부하의 증가로 인하여 직류급전에 대한 관심이 높아지고 있으며, 이에 대한 보호협조방식에 대한 연구가 활발히 이루어지고 있다. 그러나 직류급전방식을 사용하는 기존의 직류 부하망과 도시철도 등은 비접지방식인 IT 접지 시스템으로서 지락고장발생 시 고장전류의 경로가 없고, 정상상태 전류에 비하여 큰 차이가 발생하지 않기 때문에 지락고장검출이 어려운 실정이다. 따라서 본 논문에서는 절연저항측정장치(IMD : Insulation Monitoring Device)를 직류 비접지계통의 보호기기로 활용하기 위하여, IMD의 검출원리를 정식화한다. 이를 바탕으로 IMD의 신호주입방식에 의한 출력 값을 웨이블릿변환기법으로 분석하여, 사고검출을 신속하고, 정확하게 판단할 수 있는 검출알고리즘을 제안한다. 또한, 상용전력 계통해석프로그램인 PSCAD/EMTDC를 이용하여, 직류 비접지계통과 IMD를 모델링하고, MATLAB을 이용한 웨이블릿변환 수치해석모델링을 수행한다. 이를 바탕으로 직류 비접지계통의 지락사고를 해석한 결과, 본 논문에서 제안한 IMD의 사고검출 알고리즘의 유효성을 확인하였다.

저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구 (A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank)

  • 손석금
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.562-567
    • /
    • 2020
  • 본 논문은 저장 탱크용 임시전력설비를 보호하기 위한 목적으로 특히 변압기를 감시하고 절연파괴 등과 같은 고장을 차단하고 보호하기 위한 보호계전기 정정에 관한 연구이다. 전력계통에 단락 또는 지락고장 등과 같은 이상이 발생하였을 때 이를 검출하여 고장이 발생한 기기 및 설비를 신속하게 차단하고 전력계통으로부터 분리하여 전력공급에 지장이 없도록 하여야 한다. 전력계통의 이상 상태를 빠르고 정확하게 감지할 수 있는 보호계전기의 정정이 중요하다. 또한 보호협조를 위해 고장종류와 고장의 원인을 정확히 적용한 고장전류 계산이 보호계전기 정정에 가장 중요한 요소이다. 저장 탱크용 임시전력설비 보호를 위해 적용하는 과전류계전기, 지락과전류계전기, 부족전압계전기, 지락과전압계전기 등이 보호협조가 가능하도록 보호계전기 정정 방법에 대해 연구하였다.