• 제목/요약/키워드: Insulation Cable

검색결과 389건 처리시간 0.025초

Insulation Test for the 22.9 kV Class HTS Power Transmission Cable

  • J.W. Cho;Kim, H.J.;K.C. Seong;H.M. Jang;Kim, D.W.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.48-51
    • /
    • 2003
  • HTS power transmission cable is expected to transport large electric power with a compact size. We are developing a 3-core, 22.9 kV, 50 MVA class HTS power cable, and each core consists of a conductor and shield wound with Bi-2223 tapes, electrical insulation with laminated polypropylene paper (LPP) impregnated with liquid nitrogen. This paper describes the design and experimental results of the model cable for the 22.9 kV, 50 MVA class HTS power transmission cable. The model cable was used the SUS tapes instead of HTS tapes because of testing the electrical characteristics only. The model cable was 1.3 m long and electrical insulation thickness was 4.5 mm. The model cable was evaluated the partial discharge (PD), AC and Impulse withstand voltage in liquid nitrogen. The AC and Impulse withstands voltage and PD inception stress was satisfied with the standard of Korea Electric Power Corporation (KEPCO) in the test results. The 3-core 22.9 kV, 50 MVA class HTS power cable has been designed and manufactured based on these experimental results.

Insulation Characteristics of the Model Cable for 22.9 kV Class HTS Power Cable

  • Kim, Hae-Jong;Seong, Ki-Chul;Cho, Jeon-Wook;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Kim, Sang-Hyun
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.542-543
    • /
    • 2005
  • In this paper, describes the fabrication and dielectric insulation characteristics experimental results of the model cable for the 22.9kV class HTS power cable. The model cable were tested with partial discharge(PD), AC and impulse withstand voltage in liquid nitrogen($LN_2$) and liquid nitrogen pressure. In these test results, PD inception stress and AC, impulse breakdown strength increase as the pressure of the liquid nitrogen increases.

  • PDF

송전급 HTS 케이블용 반합성지의 두께에 따른 절연특성 연구 (A Study on Insulation Characteristics by Thickness of Laminated Polypropylene Paper for an HTS Transmission Cable)

  • 최진욱;최재형;김해종;조전욱;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.35-38
    • /
    • 2009
  • The high temperature superconducting(HTS) power cable, as a key component of the next generation power transmission system, operates cost-effectively because of much less transmission loss. Currently, a world-wide research has been undertaken actively. In this research, we designed insulation thickness and investigated thickness effect of laminated polypropylene paper(LPP) which is insulation material of HTS cable in case of AC and impulse breakdown.

초고압 XLPE 케이블용 조립형 직선 접속함을 모의한 계면질서의 부분방전 패턴 연구 (A Study of Partial Discharge Patterns On the Simulated Interface of Prefabricated Joint for Ultra Power Cable)

  • 백주흠;김정년;신두성;이창영;김충식;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1102-1104
    • /
    • 1999
  • It is very essential to find out defects and remove them in the insulation at the early stage because the defects in the insulation induce PD which deteriorates the material, resulting in the breakdown. In the real application of high voltage, the interface of the different insulation is the weakest place for both electrical and mechanical aspects. In this paper, characteristics of PD caused by the artificial defects, such as metallic particles, voids and moist fibers, at the interfaces of the cable joint (PJB) were investigated using the specially designed electrode system.

  • PDF

운전 중인 고전압 케이블의 절연저항 측정 및 수명평가장치의 개발 (Development of Equipment to Measure Insulation Resistance and Evaluate the Lifetime of High-voltage Cable in Operation)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.237-242
    • /
    • 2014
  • 이 논문은 발전소에서 설치 운전 중인 6.6kV 고전압 케이블이 시간에 따라 성능이 악화되는 현상의 추세를 결정하는 수명지수를 파악하기 위한 논문이다. 우리가 연구한 케이블 시스템은 설치 후 13 년 동안 운전하고 있다. 삼상전력에 연결되는 변류기, 온도센서 LPF 등을 이용한 측정장치를 개발하여 케이블의 절연저항 변화 특성을 해석하였다. 고전압 22kV 케이블과 비교하면 절연체의 두께가 더 두껍기 때문에 특성을 다르게 나타낸다. 동작시간이 경과함에 따라, 절연저항이 계속 감소하지 않음을 확인 하였다. 일정한 값으로 감소하다가 더 이상 감소하지 않고 상하진동하는 특성을 나타내었다. 지난 13 년 동안의 열화과정을 파악할 수 없었지만, 시스템이 안정 상태에서 동작을 하였다는 사실은 열화가 아직 발생하지 않았다는 의미이다. 이런 경우에는, 수명지수를 예측할 수 없기 때문에 케이블의 수명을 정량적으로 예측할 수 없음을 확인하였다.

22kV CV케이블에 있어서 절연열화현상의 고찰 (A Study on Insulation Degradation Phenomena in 22kV CV Power Cable)

  • 강무성;김동식;정성룡;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1797-1800
    • /
    • 1996
  • In this study, the insulation selected in degra-dated-power cable has been observed and aging process about the insulation has been investigated. Most Insulation aging process initiates in the interface of semiconducting layer and the type of the process is the fractal form that was observed between the the semiconducting layer and insulation layer. It is possible to estimate degree of the degration of cable with breakdown test and obtained data have been used to get parameters in order to use Weibull distribution. With this method it is considered to be possible to estimate situation of degration and life prediction.

  • PDF

액체질소에서 절연지 및 mini-model 케이블의 전기절연 특성 (The Electric Insulation Characteristics of the Insulation Paper and Mini-model Cable in Liquid Nitrogen)

  • 곽동순;김영석;정종만;김해종;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.224-227
    • /
    • 2003
  • According to the increasing power demands for the power transmission of major cities, HTS power cables which have large current capacity and low power loss will be needed. In this paper we have studied breakdown voltage properties of paper/liquid composite insulating system for HTS cable insulation. And we measured the dielectric loss(tan$\delta$) of mini-model cable. From results, the insulation paper-ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

고온초전도 케이블용 cryostat의 단열조건에 대한 열침입량 측정 (Experiment on Heat Loads Invaded into HTS Cable Cryostat under Cryogenic Insulation System)

  • 김도형;정원묵;김동락;양형석;조승연;황시돌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1564-1569
    • /
    • 2004
  • Insulating a heat from the environment is the most important in cryogenic applications like HTS cable system. Vacuum and MLI(Multi-Layer Insulation) have been widely used to get highly efficient cryogenic insulation. In this study, experiment on annular cylinder regarded as basic model of HTS cable cryostat has been performed to measure the heat loads. To investigate the effectiveness of radiation shields in cryogenic insulation system, the experiments are carried out to various number of the shields. The measured values are compared with the results estimated theoretically. The heat loads invaded from the environment was determined by liquid nitrogen boil-off calorimetry.

  • PDF

해저 케이블 시스템의 열화진단 및 유지보수 (Insulation Diagnostics and Maintenance of Submarine Medium Voltage Power Cable Systems)

  • 이동영
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.80-86
    • /
    • 2003
  • 본 논문에서는 육상의 지중전력케이블에 비해 유지보수가 힘들고 사고의 파급효과나 사고복구에 큰 어려움이 따르는 해저케이블을 대상으로 진단시험 및 유지보수에 대한 연구를 수행하였다. 본 연구의 목적은 사고위험이 높은 해저선로에 대한 경제적이고 효율적인 열화진단 및 유지보수에 있다. 진단시험 결과, 해저케이블의 열화정도는 매우 심각하며 열화가 계속 진전되고 있음을 확인하였다. 단말부 교체시공 후 재 진단시험을 실시한 결과, 전체적인 열화상태가 개선되었음을 확인하였으며 단말부 및 케이블 절연부에 대한 전기적 특성시험과 화학구조분석 시험 결과, 전체 케이블 시스템의 열화는 주로 단말부 열화에 기인함을 알았다. 상기 결과에 따라 본 연구에 사용된 진단기법 및 유지보수 절차가 해저케이블시스템의 경제적인 관리에 매우 효과적임을 학인하였다.

유한요소법을 이용한 내화전선의 열해석에 관한 연구 (A Study on the Thermal Analysis of Fire-Resistance Cable using FEM)

  • 오홍석;이상호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권5호
    • /
    • pp.338-343
    • /
    • 2004
  • In general, the insulation and protective sheaths on electrical conductors are made of combustible substances like PVC, natural or synthetic rubbers, and other organic or synthetic materials. When an electrical fire starts due to overheating of conductors/joints or sparking/arcing, the first thing to ignite is usually the insulation on the cables. When the insulation bums, the produced fumes are very toxic. To solve the problem, we have surely need the fire resistance cable that doesn't bum in a high temperature and emit toxic fume for operating a disaster prevention installation. In this paper, we have simulated the thermal analysis for the fire resistance cable according to the values of current in a overload and a short, and the values of outside flame with the fire resistance cable of the L's company product(600 V, FR-8 : Four Core) using the finite element method(Flux2D).