• 제목/요약/키워드: Insulation Breakdown Strength

검색결과 178건 처리시간 0.028초

Detailed Study on Insulation Coordination of a 25kV Power System Connected with a VCB and Transformer

  • Baek, Byung-San;Kim, Yong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1245-1249
    • /
    • 2017
  • Recently, unusual transformer failures have been reported in 25kV power systems connected with a VCB and transformer. In this study, performance of the protection system, dielectric strength of the transformers, characteristics of switching surges and resonance phenomena were analysed and assessed. All investigations regarding the insulation breakdown of the transformers were carried out by simulations, laboratory tests, factory tests and on-site measurements in order to thoroughly investigate the root causes. Furthermore, experimental methods for investigating the resonance phenomenon were derived and tests were conducted applying the derived method to recreate the phenomenon in the transformer. It is found that resonance between the transformer and switching surge generated by closing a VCB can initiate the breakdown of internal windings of a transformer.

Insulation Characteristics of the Model Cable for 22.9 kV Class HTS Power Cable

  • Kim, Hae-Jong;Seong, Ki-Chul;Cho, Jeon-Wook;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Kim, Sang-Hyun
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.542-543
    • /
    • 2005
  • In this paper, describes the fabrication and dielectric insulation characteristics experimental results of the model cable for the 22.9kV class HTS power cable. The model cable were tested with partial discharge(PD), AC and impulse withstand voltage in liquid nitrogen($LN_2$) and liquid nitrogen pressure. In these test results, PD inception stress and AC, impulse breakdown strength increase as the pressure of the liquid nitrogen increases.

  • PDF

외부전극 헝광램프의 핀홀 현상 (Pinhole Phenomena in the External Electrode Fluorescent Lamps)

  • 길도현;김상범;송혁수;유동근;이상훈;박민순;강준길;조광섭;조미령;황명근;김영욱
    • 한국진공학회지
    • /
    • 제15권3호
    • /
    • pp.266-272
    • /
    • 2006
  • 외부전극 형광램프의 구동에서 과도한 전력을 인가하면, 외부전극 부분의 유리관 표면에 작은 원형의 구멍(핀홀)이 발생하여 램프가 파손된다. 핀홀은 외부전극과 유리관을 유전층으로 하는 캐패시터의 절연파괴이며, 이러한 절연파괴력은 인가되는 전력에 비례한다. 유전상수가 K인 램프에 흐르는 전류가 작을 때, 핀홀이 발생하는 유리관의 절연파괴 전기장의 세기는 약 3K kV/mm,이다. 이러한 절연파괴 전기장의 세기는 램프에 흐르는 전류가 커질수록 작아진다.

평등전계에서 SF6/CF4 혼합가스의 AC절연내력 특성 (AC Breakdown Voltage Characteristics of SF6/CF4 in Uniform field)

  • 황청호;박신우;김남렬;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제20권4호
    • /
    • pp.381-387
    • /
    • 2007
  • The excellent dielectric properties of $SF_6$(sulfur hexafluoride) have lead to its wide range of application in the field of high voltage insulation. Because there has been some recent concern regarding the environmental impacts of $SF_6$ binary gas mixtures, with $SF_6$ as the main component, have been the subject of active research. Scientists have long been interested in the possible use of gaseous fluorocarbons, including $CF_4$ (Carton Tetrafluoride), in high voltage applications due to their inert character and high dielectric strength. This paper presents experimental results concerning the AC breakdown characteristics lot various mixtures of $SF_6/CF_4$ in a test chamber and 25.8 kV GIS (Gas Insulation Switchgear) at practical pressures (0.1-04 MPa) and gap lengths (0.5 mm, 1 mm) in a test chamber. In the result, it was observed that an increase in the dielectric strength is attained through the addition of $SF_6$ to $CF_4$. It is possible to make an environment friendly gas insulation material while maintaining the dielectric strength by combing $SF_6$ and $CF_4$ which generates a lower level of the "global warming" effect.

Effects of Temperature on Dielectric Breakdown Strength of Epoxy Compounds Filled with Natural Zecolite

  • Kim, You-Jeong;Park, Hyeong-Ki;Kim, Sang-Wook
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.544-547
    • /
    • 1999
  • To develop the better insulants. the zeolite particle, which is aluminosilicate mineral, was filled In the DGEBA/MDA/SN epoxy resin system. Dynamic DSC curves of cured specimens with various contents of zeolite were observed and the glass transition temperature(T$_{g}$) was obtained. According to this result, we could carry out the experiment concerned with the dielectric breakdown strength around T$_{g}$ and find the limit temperature for the application of the DDEBA/MDA/SN system filled with natural zeolite. T$_{g}$ increased with the content of zeolite. As the temperature increased, the dielectric breakdown strength decreased rapidly, in the region of T$_{g}$. At the high temperature, the deterioration by electrical stress was activated. The diameter of puncture at the high temperature was larger 7han that at the room temperature.erature.

  • PDF

고온 초전도 케이블 절연을 위한 절연지의 인장응력 및 절연파괴 특성 (The Characteristics of Electrical Breakdown and Tensile Stress of Dielectric Paper for Insulation of HTS Cable)

  • 김영석;곽동순;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.61-64
    • /
    • 2003
  • The degradation of the dielectric properties of insulating papers that were used under loaded conditions at cryogenic temperature was paid attention. Electrical and tensile stress properties of dielectric paper at cryogenic temperature have been investigated to optimum insulating design of high-Tc superconducting(HTS) cable. Tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain could know that decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen was decreased.

  • PDF

함침기법에 따른 인버터 구동 유도전동기 고정자 권선의 절연성능 평가 (Evaluation of Insulation Performance for Stator Winding of the Inverter Driven Induction Motor According to Impregnation Methods)

  • 황돈하;강동식;이인우;김동희;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.487-492
    • /
    • 2006
  • Inverter driven induction motors with high speed switching and advanced PWM techniques are widely used for variable speed applications. Recently, the insulation failures of stator winding have attracted much concern due to high dv/dt of IGBT PWM inverter output. In this paper, the detailed insulation test results of 26 low-voltage induction motors are presented. Six different types of insulation techniques are applied to 26 motors. The insulation characteristics are analyzed with partial discharge, inception voltage, AC current, and dissipation factor tests. Also, breakdown tests by high voltage pulses are performed. From the above test data the effects due to different wires and insulation techniques on the insulation characteristics of low-voltage induction motors are compared and analyzed. The insulation technique to enhance the insulation strength is suggested from the test results.

  • PDF

나노/마이크로 에폭시 복합체의 전기적, 열적특성 분석 (Analysis of electrical, thermal characteristic of Nano/Micro Epoxy composite)

  • 정의환;윤재훈;임기조;정수현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.99-99
    • /
    • 2010
  • Polymer nanocomposite has been attracting much attention as a new insulation material, since homogeneous dispersion of nm-sized inorganic fillers can improve various properties significantly. In this paper, various kinds of epoxy based nanocomposites were made and AC breakdown strength of Nano-TiO2 and micro-silica filler mixture of epoxy based composites were studied by sphere to sphere electrode. Moreover, nano- and micro-filler combinations were adopted as an approach toward practical application of nanocomposite insulation materials. Nano-TiO2 particle size is about 10nm and composites ratio was resin (100) : hardener (82) : accelerator (1.5). AC breakdown test was performed at room temperature (25 [$^{\circ}C$], 80 [$^{\circ}C$] and 100 [$^{\circ}C$] in the vicinity of Tg (90[$^{\circ}C$]). And thermal conductivity were measured by ASTM-D5470.

  • PDF

XLPE의 열처리에 의한 결정화도, 가교부산물의 확산에 따른 교류파괴전압 특성 (AC Breakdown Strength According to Crystallinity and Diffusion of Crosslink By-products by Annealing of XLPE)

  • 김영호;이상진;이승엽;최명규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1608-1610
    • /
    • 2000
  • In this work, the effect of annealing on physical and electrical properties of XLPE cable insulation was investigated. One sample was non-annealed and the other two samples were treated under air circulated oven at 80$^{\circ}C$ for five and ten days. In the DSC patterns of annealed specimen, new peaks appeared at near 80$^{\circ}C$ as a proof of thermal history. The degree of crystallinity increased by annealing effect. In the FT-IR spectrums, the change of absorbances to acetophenone and cumyl alcohol were observated according to the radial direction of cable insulation. They slowly diffused into both semi-conductive layer of the cable in proportion to annealing time and lastly led to near equilibrium state through cable insulation. The AC breakdown strength did not increased but the values were stabilized by effects of crystallinity and diffusion of by-products.

  • PDF

$SF_6$ 가스중 PET Film의 절연특성 (Insulated Characteristics of PET Film under $SF_6$)

  • 김정달;정장근;주성철;이덕진;박재윤;이용길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2120-2122
    • /
    • 1999
  • $SF_6$ gas has been widely used the gas insulated transmission line, gas insulated transformer and gas insulated substation and Polyester film used as the turn insulation with other material. $SF_6$ gas has been actively studied in domestic and foreign countries. In general, when dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents the insulation strength of turn insulation of $SF_6$-PET film studied under application of AC voltage, constitute of the plane to plane with PET Film. The results obtained in experimental are summarized that Partial Discharge Initial Voltage(PDIV) of turn insulation depend on gas pressure, but Breakdown Voltage(BDV) did not depend on gas pressure.

  • PDF