• 제목/요약/키워드: Insulation Breakdown Strength

검색결과 178건 처리시간 0.029초

탄성형 에폭시의 흡습에 따른 전기적인 특성 (Electrical Properties according to Moisture Absorption of Elastomer Epoxy Resin)

  • 박재열;박성희;이강원;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1155-1158
    • /
    • 2003
  • In this paper, we studied on the electrical characteristics of insulation material of elastomer epoxy. As the results of test, properties of epoxy represent differently according to elastomer contents. Also, its permittivity, tan ${\delta}$ and BDV(Break-Down Voltage) strength show big difference when those compare before moisture absorption test and after moisture absorption test. From this test we find results that mush elastomer contents can cause insulation properties to degrade.

  • PDF

방사선을 조사한 EPDM에서 전기적 특성의 경년열화 효과 (The Aging Effects on Electrical Properties for the Irradiated EPDM)

  • 류부형
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.78-87
    • /
    • 2000
  • The $\gamma$-ray irradiation and aging effects on electrical characteristics of $^{60}Co$ $\gamma$-ray irradiated ethylene-propylene-diene-terpolymer(EPDM) contained with 1 to 3phr phenolic and quinolinic antioxidants as antirads were investigated. The marked effects of type and amounts of the antioxidant on the volume resistivity and AC breakdown strength of the $\gamma$-ray irradiated EPDM are different. A phenolic antioxidant(IR 1010) contribute to improving the electrical insulation properties on the EPDM better than quinolinic antioxidant(Kumanox RD) during irradiation. In aging the irradiated EPDM specimens contained antioxidants at room temperature in air, it was shown a improvement of insulation properties due to radical scavenging and crosslinking of EPDM aged until 360 days.

  • PDF

초전도변압기 턴간 절연재료의 V-t 특성 (V-t characteristics of turn insulator of HTS transformer)

  • 정종만;류엔반둥;백승명;이창화;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.218-221
    • /
    • 2003
  • In the response to increasing the demands for electrical energy, much effort aimed to develop and commercialize HTS power equipments have been made around the world. Among them HTS transformer is one of very Promising one. For the development, the cryogenic insulation technology should be established. In this paper V-t characteristics of turn insulator, Kpaton, among insulation components of HTS transformer was discussed with Weibull distribution and n-value. V-t tests of Kapton were conducted using Cu tape electrodes shaped HTS tape depending on wrapping number. The n-values of 2 and 3 times wrapped tape are 27.54 and 30.58. Although breakdown strength of the 3 times one is higher than the 2 times the 3 times one have more weak points with overlapping so it have higher probability of incidental accidents.

  • PDF

첨가제를 함유한 저밀도 폴리에틸렌의 절연특성에 관한 연구 (A Study on Insulation Characteristics of Low Density Polyethylene Contained Various Additives)

  • 이청;김규백;류부형;김기엽;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.483-486
    • /
    • 1999
  • The treeing inhibitors of barbituric acid derivatives and azocompounds effects on the electrical properties of crosslinked low density polyethylene were investigated. The electrical treeing parameters for tree inception voltage, AC breakdown strength. volume resistivity, capacitance and dissipation factor at 1Mz and thermoluminescence measurements were discussed. From the results, 4- (4-nitrophenylazo) resorcinol among the treeing inhibitors was shown good insulation characteristics.

  • PDF

THE EFFECTS OF SEALING ON THE PLASMA-SPRAYED OXIDE-BASED COATINGS

  • Kim, Hyung-Jun;Sidoine Odoul;Kweon, Young-Gak
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.53-58
    • /
    • 2002
  • Electrical insulation and mechanical properties of the plasma sprayed oxide ceramic coatings were studied before and after the sealing treatment of the ceramic coatings. Plasma sprayed A1$_2$O$_3$-TiO$_2$ coating as the reference coating was sealed using three commercial sealants based on polymer. Penetration depth of the sealants to the ceramic coating was evaluated directly from the optical microscope using a fluorescent dye. It is estimated that the penetration depth of the sealants to the ceramic coating is from 0.2 to 0.5 mm depending on the sealants used. The preliminary test results with a DC puncture tester imply that the dielectric breakdown voltage mechanism of plasma sprayed ceramic coatings has been determined to be a corona mechanism. Dielectric breakdown voltage of the as-sprayed and as-ground samples have shown a linear trend with regard to the thickness showing an average dielectric strength of 20 kV/mm for the thickness scale studied. It is also shown that grinding the coating before sealing and adding fluorescent dye do not agent the penetration depth of sealants. All of the microhardness, two-body abrasive wear resistance, bond strength, and surface roughness of the ceramic coating after the sealing treatment are improved. The extent of improvement is different from the sealants used. However, three-point bending stress of the ceramic coating after the sealing treatment is decreased. This is attributed to the reduced micro-crack toughening effect since the cracks propagate easily through the lamellar of the coating without crack deflection and/or branching after the sealing treatment.

  • PDF

초고압 $SF_6$가스차단기의 소전류 차단성능 해석기술 II (Evaluation Method II of the Small Current Breaking Performance of SF$_6$-Blown High-Voltage Gas Circuit Breakers)

  • 송기동;이병윤;박경엽;박정후
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권8호
    • /
    • pp.384-391
    • /
    • 2001
  • The insulation strength between contacts after current interruption to the transient recovery voltage i.e., the dielectric recovery strength should be estimated for the evaluation of the small capacitive current interruption capability. Many authors have used theoretical and semi-experimental approaches to evaluate the transient breakdown voltage after the current interruption. Moreover, an empirical equation, which is obtained from a series of tests, has been used to estimated the dielectric recovery strength. Un this paper, the theoretical method which is generated from the streamer theory has been applied to real circuit breakers in order to evaluated the interruption capability. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

친환경절연재의 절연성 평가 (Assess of Breakdown Characteristics about Environmentally Friendly Gases)

  • 최은혁;구본호;김이국;이광식
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.96-100
    • /
    • 2009
  • 산업사회의 발달과 더불어 신뢰성 높은 양질의 전기에너지와 운전 및 보수의 간편화, 계통 운용의 신뢰성, 안전성 확보가 요구되고 있다. 따라서 본 논문은 각종 전력설비에서 $SF_6$을 대체할 수 있는 친환경절연제로 연구되고 있는 $N_2-O_2$ 혼합가스($N_2:O_2=100$ : 0, 79 : 21, 60 : 40, 40 : 60) 절연파괴특성을 구명(究明)하여 이를 $SF_6$가스의 특성과 비교하였다. 이상의 연구 결과, 제조공기와 Dry-Air 절연특성을 구명함으로서 각종 전력응용 설비의 절연설계에 $SF_6$ 대신 친환경적인 모의공기를 사용 가능함을 본 연구에서 구명(究明)하였다. 제조공기를 이용한 친환경적인 절연재 사용으로 지구의 온난화현상 감소에 크게 기여할 것으로 기대된다.

배전급 케이블 종단부의 결점이 전기적 특성에 미치는 영향 (Influence of Defects on Electrical Characteristics of Distributing Cable Termination)

  • 김상현;최재형;최진욱;김영석;김선구;백승명
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.190-195
    • /
    • 2009
  • 본 논문은 모의된 시공불량에 따른 결점을 가진 배전급 종단부의 전기적인 사고에 대하여 실험적으로 조사한 것을 나타낸다. 실험에 조립형과 열수축형인 두 개의 종단재를 사용하였다. 우리는 시공불량에 따른 모의 결점을 가진 케이블 종단부를 제작하여 교류 및 임펄스 내전압 시험과 같은 절연 특성을 고찰하였다. 두께 감소나 하우징의 스트레스콘과 반도전층 사이의 틈과 같은 결점의 영향에 대하여 연구하였다. 절연체의 두께 감소 시 교류 절연파괴 강도는 급격히 감소하였고 이 절연체의 절연파괴 흔적은 타원형으로 나타났다. 스트레스콘과 반도전출 사이의 틈은 절연내력에 매우 나쁜 영향을 주었다. 열수축형에서, 교류 절연파괴 전압은 가열 시간이 짧을 때 낮아졌다.

평가시공불량을 모의한 배전급 케이블 종단부의 전기적 사고 연구 (A Study on Electrical Accident of Distributing Cable Termination with Simulated Badness Construction)

  • 최재형;최진욱;김상현;김영석;김선구;백승명
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.465-470
    • /
    • 2008
  • This paper introduces experimental investigates of an electrical accident of the distributing cable termination with simulated badness construction. We prepared two termination kites, one is built-up type, the other is heat contraction type. Also, we manufactured cable termination that have simulated defect by badness construction and measured their insulation characteristics such as ac (35kV, 1min) and impulse (95kV, $1.2{\times}50{\mu}s$) withstand test. The influence of defects such as thickness and the gap between stress-con of housing and semi-conductor on insulating properties of the termination have been studied. The thickness decrease of insulator decreases ac breakdown strength. Dielectric breakdown traces of insulator that is damaged by knife displayed other shape. The gap of between housing and semiconductor deteriorates dielectric strength of insulator seriously.

  • PDF

UV 센서를 이용한 절연애자의 코로나 방전 측정 및 자외선 이미지의 비교 (Comparison of UV images and Measurement of the Corona Discharge from Insulators using the UV Sensor)

  • 김영석;최명일;김종민;방선배;송길목
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.899-904
    • /
    • 2011
  • Inspections and diagnoses of corona discharge are important in order to prevent electrical faults of external insulation in power systems. This paper studies a measurement of ultra-violet rays(UV) strength of corona discharges on insulators using a UV sensor with an optic lens. The data has been compared with the images of a UV camera. The UV sensor estimated that DC voltage needed to be set at 700V for accurate data analysis of the properties of UV detected during corona discharge. UV was generated at 60kV when the corona discharge occurred. UV strength and images of UV increased at a high voltage. The image area of the UV using a UV camera and the detection of UV using a UV sensor have shown, that the polymer insulator mounted on a live part must be checked when the applied voltage on the good polymer insulator is greater than 37.5% of its breakdown voltage.