Comparison and Analysis between the simulation and test result for Quality Assessment of Surge Protective Insulating Transformer. (서지방호용 절연변압기 성능시험관련 모의해석 및 시험결과와의 비교분석)

  • Choi Young-Ha;Kim Myung-Young;Lee Kang-Won;Ohn Jung-Ghun;Song Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.519-522
    • /
    • 2003
  • 'KRS 6330-3256라' standard regulates performance test of insulating transformer for protecting the electronic interlock linkage equipment which is being done by test procedures and methods according to the standard. The balance/unbalance test evaluating the performance of transformer are applied by impulse voltage($l2/200{\mu}s$) but affected by many other factors. Therefore, the review about these is necessary to have the reliability and reappearance of test results. In this paper, we have simulated about several phenomenon appearing in real balance/unbalance test and compared simulated results with real ones. With the basis of these results, the influence to test result of inner and outer factors are investigated and analyzed and established the plan boosting the reliability and reappearance of test results.

  • PDF

Discharge Signal Detection in Insulating Oil using the Optial Fiber Sagnac Interferometer (광섬유 Sagnac 간섭계를 이용한 유중방전 신호검출)

  • Lee, Jong-Kil;Lee, June-Ho;Kim, Sang-Joon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.622-626
    • /
    • 2000
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Sagnac interferometer was proposed to detect the discharge signals. The needle-sphere electrode system in insulating oil generated the signals. The performance of OF sensor was checked by sinusoidal calibration signal generated by PZT actuator at 198KHz. The detected discharge signals consisted of acoustic signal and the electrical noise. The noise signal could be removed by digital low pass filter. It was demonstrated that the OF sensor in this research had a possibility to detect the discharge signals in power apparatus.

  • PDF

A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer (식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구)

  • Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

A Study on the Mathematical Model for Life Diagnosis of Electrical Insulating Materials (전기절연재료의 수명진단에 관한 수학적 모델에 관한 연구)

  • Park, Hong-Tae;Lee, Tae-Sik;Kim, Hie-Dae;Lee, Kyu-Chul;Lee, Jong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.569-571
    • /
    • 1993
  • This paper describes a life expectation of electrical insulating materials using a mathematical model. The mathod simultaneously uses the maximum likelihood estimation and the Newton-Raphson method. By using these method, we will reduce time and costs in voltage-life aging test.

  • PDF

A study on the arc discharge characteristics of liquid insulating materials for electrical discharge machine (방전가공기용 액체 절연재료의 아크 방전 특성 연구)

  • 김상현;김해종;마대영;신태민
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.564-571
    • /
    • 1995
  • This paper deals with the arc discharge characteristics of kerosene oil as a basic study on electrical discharge machine. Using needle electrode the discharge voltage, discharge current, discharge energy and the shape of discharge crater are measured. In consequence, it becomes clear that the discharge crater(depth, height, diameter) is depending on the discharge energy. Rapid increase in depth, height and diameter of discharge crater was observed during initial discharge, where discharge energy is large. However, rather slow decrease of those values was found when discharge energy is low or N is more than 3. As the ratio of $I_p$$T_on$ increase, the shape of discharge crater gets near circle. The protuberances of the discharge crater were not formed by the melted needle electrode but by the that of work piece.

  • PDF

A study on development of program for estimation the Lifetime of insulating materials (절연재료의 수명예측을 위한 프로그램개발에 관한 연구)

  • 박성민;배덕권;정인재;박우현;이기식;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.699-702
    • /
    • 2000
  • Today, electrical machine is being large capacitor and EHV(Extra High Voltage) of power equipment is a need of high reliability of insulating matetials. Therefore, it is a need of fixed appraisement of lifetime to used data of breakdown. This paper studied a development of the program for estimation the lifetime of insullating materials and the long-time breakdown voltage by experimentation. The estimation program is based on the "Inverse Power Law", defined V$\^$n/t is constant. After gaining the life exponent n, it is mapping the long-time breakdown voltages. On the base of life exponent, the estimation of lifetime and usefulness of the insulation systems are possible, furthermore easy calculation is possible.

  • PDF

PMMA수지의 수 Tree현상

  • 유근민;이재선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.7 no.1
    • /
    • pp.18-24
    • /
    • 1982
  • The Tree phenomenon of the PMMA resin depends on an annex of the inorganic fillers and water. If the internal of an arganic insulating materials exist the fault of inorganic fillers, Void and Projecting part, the high voltage concentrates in this place. It leaves a trace about the partical breakdown and this phenomenon develops into the degration of insulating material. This paper researchses that have an effect on the tree phenomenon by the inorganic fillers and water. The results is as follow. (1) The growth of tree are less the influence of inorganic fillers. Because , the constant of water are more. (2) If the tree branches contact the inorganic filler, the advance are relaxation.

Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers (전력용 변압기의 열화에 의해 생성된 부산물의 분석)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

공기-절연유복합유도체의 절연파괴현상에 관하여 1

  • Chul Je Cho
    • 전기의세계
    • /
    • v.23 no.3
    • /
    • pp.60-66
    • /
    • 1974
  • This paper is to study on the phenomena that the compound dielectric strength through double layers of air-insulating oil dielectrics is much lower than that of air dielectrics only. the change of the dielectric strength by the variance of air gap depends on the characteristics of air gap discharge and, in case of commercial voltage, the degree of dependance is greeter than in case of direct current voltage.

  • PDF

A Study on the Ultraviolet Aging Characteristics of Outdoor Polymeric Insulating Materials (옥외용 고분자 절연재료의 자외선 열화특성 연구)

  • Kim, Yeong-Seong;Jeong, Sun-Ok
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.409-413
    • /
    • 1999
  • Recently, the polymeric insulators have been accepted in several countries for the outdoor high voltage applications. In comparison with the conventional porcelain, polymeric insulators offer various advantages such as light weight, superior vandal resistance and better contamination performance. The outdoor polymeric insulating materials such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-ray on the surface of silicone rubber were investigated by using the weather-Ometer. The accelerated aging stresses were simulated by UV radiation, high temperature and humidity as well as water spray. These aging characteristics were examined through contact angle measurements, tracking resistance test, FT-IR and SEM/EDS analysis. The experimental results showed that tracking resistance decreases with increase in the UV-ray irradiation period. But the surface of silicone rubber kept hydrophobicity. It is found that the inorganic filler such as)$ Al(OH_3$ improves tracking resistance and the $Tio_2$is very effective in preventing degradation of silicone rubber surface from UV-ray.

  • PDF