• 제목/요약/키워드: Insulating Material

검색결과 711건 처리시간 0.022초

A Study on Fabrication and Characterization of Inorganic Insulation Material by Hydrothermal Synthesis Method (2) (수열합성법을 이용한 무기계 단열소재 제조방법 및 특성에 관한 연구 (2))

  • Seo, Sung-Kwan;Chu, Yong-Sik;Lee, Jong-Kyu;Song, Hun;Park, Jae-Wan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • 제1권3호
    • /
    • pp.225-232
    • /
    • 2013
  • The inorganic insulating material was fabricated with quartzite, ordinary portland cement(OPC), lime, anhydrous gypsum and foaming agent by hydrothermal reaction. The inorganic insulating material was fabricated by using autoclave chamber under high-temperature and high-pressure. The inorganic insulating material is a porous lightweight concrete. Because of its porous structure, properties of inorganic insulating material were light-weight and high-heat insulation property. Properties of fabricated inorganic insulating material were $0.26g/cm^3$ in specific gravity, 0.4MPa in compressive strength and 0.064W/mK in thermal conductivity. In this study, the inorganic insulating material was fabricated and analyzed at different size of quartzite/OPC, various foaming reagent and functional additives to improve the properties. Consequently, polydimethylsiloxane can improve density and thermal conductivity. Especially, polydimethylsiloxane showed excellent improvement in compressive strength.

The Characteristics of Potential Decay on the Corona Electrified Composite Insulating Material by Surface Condition (코로나 대전된 복합절연재료의 표면상태가 전위감쇠에 미치는 영향)

  • 황명환;정재희;조한구;송진호;이덕출
    • Journal of the Korean Society of Safety
    • /
    • 제12권2호
    • /
    • pp.65-69
    • /
    • 1997
  • Especially, Fiber glass Reinforced Plastics(FRP) is the best composite insulating material which has been so far. Therefore, it's worthy of notice to investigate on the corona electrified composite insulating material by surface condition. And then some other materials will be focussed on. In this study, charge decay were measured with charging-time and grid voltage on FRP composite material surface in order to analyze the mechanism. As a result we have studied that the way of the composite glass fiber(GF) and Polymer and the condition of the contaminated surface was different. In case of the GF is mixed with vertical, charge decay speed is fast because the charge is easily leaked. On the other hand, the surface charge decay speed is depend on conductive or insulated of the contaminant.

  • PDF

Effect of ceramic powder addition on the insulating properties of polymer layer prepared by dip coating method

  • Kim, S.Y.;Lee, J.B.;Kwon, B.G.;Hong, G.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • 제16권1호
    • /
    • pp.14-18
    • /
    • 2014
  • The mechanical, electrical and thermal characteristics of insulating materials may significantly affect the performance and reliability of electrical devices using superconductors. General method to provide insulating layer between coated conductors is wrapping coated conductor with Kapton tape. But uniform and compact wrapping without failure or delamination in whole coverage for long length conductor is not a simple task and need careful control. Coating of insulating layer directly on coated conductor is desirable for providing compact insulating layer rather than wrapping insulating layers around conductor. Ceramic added polymer has been widely used as an insulating material for electric machine because of its good electrical insulating properties as well as excellent heat resistance and fairy good mechanical properties. The insulating layer of coated conductor should have high breakdown voltage and possesses suitable mechanical strength and maintain adhesiveness at the cryogenic temperature where it is used and withstand stress from thermal cycling. The insulating and mechanical properties of polymer can be improved by adding functional filler. In this study, insulating layer has been made by adding ceramic particles such as $SiO_2$ to a polymer resin. The size, amount and morphology of added ceramic powder was controlled and their effect on dielectric property of the final composite was measured and discussed for optimum composite fabrication.

A Study on the Tree Growth by Interface Type of XLPE (XLPE의 계면형태에 따른 트리성장에 관한 연구)

  • 김철운;김영민;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.111-115
    • /
    • 1997
  • There exists a interface among the different kinds of materials in the solid insulating ones, which effects on the insulating capability heavily. The insulating construction has been developed for each usages and take themselves into several sorts. The conjunction between CV cables have the electrical weakness of solidity and solid interface, so they were focused at the long distance-line. To this background, it is very important to get the information on the interface influencing on the insulating capability of cable and to observe its procedure. In this paper, the interface was made artificially to research the effect owing to the toughness of interface, which results in the aging and treeing proceeding was observed. The polyethylen, as is generally using for the cable, was taken in this research.

  • PDF

Electric field distribution according to surface roughness of insulating paper (표면 거침도에 따른 종이절연지의 전계분포)

  • Park, Hyoung-Jun;Kim, Weon-Jong;Shin, Jong-Yeol;Kim, Soo-Won;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.323-326
    • /
    • 2004
  • The this paper is describing about the electric field distribution due to the roughness in Aramid insulating paper for electric machine. The insulting and pressboard paper have been used at electric insulating of traction motor and generators. There was a change investigation of the electric field distribution according to the roughness of specimen by simulation program of Electro. We studied the electric field distribution using boundary element method for Aramid insulator. We find out an optimal condition in insulating paper of electric machine.

  • PDF

A Study on the Streaming Electrification and Static Charge Elimination of Insulating Oil on Pipe Materials. (파이프 재질에 따른 절연유의 대전및재전에 관한 연구)

  • Kim, Y.W.;Cho, Y.K.;Shin, Y.D.;Jeong, H.D.;Lee, D.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1993년도 춘계학술대회 논문집
    • /
    • pp.72-75
    • /
    • 1993
  • The characteristic of streaming electrification and static charge diminution in Cu, Fe and Sus pipes were investigated. The Cu and Fe pipes are charged positively, whereas the Sus pipes are charged negatively. Electrification rate in Cu and Fe pipes increases with increasing a pipe length for no-charged insulating oil. The electrification rate in Cu and Fe pipes abruptly increase with increasing the temperature and flow rate of insulating oil but decrease in Sus pipes. The current flows as a direction of insulating oil in all pipes.

  • PDF

Fabrication of insulating fifes using phenolic polymer and electrical properties in MIM structure (페놀계 고분자를 이용한 절연막의 제작과 MIM구조에서의 전기적 특성)

  • 김경환;유승엽;정상범;박재철;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.347-349
    • /
    • 1999
  • We have fabricated insulating thin films using p-hexadecoxyphenol(p-Hp) that was formed phenol-formaldehyde resin of crosslinked structure from reaction with formaldehyde by LB technique. For fabricated MIM device, the possibility for insulating layers of electronic were investigated by electrical properties of their LB films according to crosslinking of LB films current-voltage (I-V) properties and frequency-capacitance (C-F) characteristics. We have provided evidence for the high insulating performance of phenol-formaldehyde thin films by the LB method. Conductivity of their LB films was as follows: pure water > 1 % aq. Formaldehyde > heat treatment, in the current-voltage (I-V) characteristics. It is demonstrated that insulation properties of crosslinked p-HP LB films were improved. In capacitance-frequency properties, the heat-treated p-HP LB films for crosslinking showed a low relative dielectric constant.

  • PDF

Development and Characteristics Evaluation of Polymer Housing Type Arresrter (폴리머 housing형 피뢰기의 개발과 특성 평가)

  • 조한구;김인성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.82-85
    • /
    • 1997
  • This paper describes the development of new type arrester for 22.9kV class distribution lines, with polymer insulating materials applied to their housings. The new arrester employs silicone insulating material for its housing, instead of the conventional porcelain housing, aiming at reduction in size and weight and explosion proof against internal short circuit failure. And, since the design of sheds is not restricted. it is possible to provide a long surface leakage distance per strike length and improve anti-contamination performance.

  • PDF

Condensation Prevention Performance Assessment Taking Into Account Thermal Insulation Performance Degradation Due to Aging for Apartment Housing

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.11-18
    • /
    • 2015
  • Purpose: The current study analyzed trends in thermal insulation performance with aging, and condensation characteristics caused by the former. Method: Thermal insulation and condensation prevention performance of an architecture were assessed using Temperature Difference Ration Inside, or TDRi. Subjects of this quantitative analysis in thermal insulation performance change due to aging included recently constructed apartments and aged apartments older than 40 years. Time series comparison and analysis were conducted to observed changes in the thermal insulation performance and condensation characteristics. Result: Analysis showed that wall insulation performance degraded with aging regardless of fortified insulating material usage or insulating material type, which caused increased danger of condensation. In addition, when fortified insulating material was installed on the connection between the walls, insulation performance degradation was lower compared to cases in which fortified materials were not used. In all cases from 1 to 10, the rate of thermal insulation performance degradation increased after 20 years of aging.

Mechanical Reliability(Life-Time) Estimation for 25.8kV Eco Solid Insulated Switchgear (25.8kV급 친환경 고체절연차단기(Solid Insulated Switchgear)에 대한 기계적 신뢰성(수명) 평가)

  • Lee, Do-Hoon;Lee, Seog-Won;Park, Seok-Weon;Kim, Young-Geun;Lee, Jhong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제59권2호
    • /
    • pp.202-205
    • /
    • 2010
  • In this paper, mechanical reliability(Life-time) estimation method for 25.8kV SIS(Solid Insulated Switchgear) has been studied. Recently enacted KEPCO's standard includes clause that have to submit a warrantable reliability data for life-time(over B10 25 years) of an epoxy-solid insulating material. Accordingly, this research was carried out on the ALT(Accelerated Life Test) and Life-Estimation method for SIS's insulating material. Mechanical life-time estimation for SIS's insulating material is to verify reliability for tensile creep & fatigue stress, which is the major mechanical stress of SIS. This study proved that SIS's reliability for mechanical stress and established that confidence for estimation results in further verification test.