• Title/Summary/Keyword: Insulating Concrete

Search Result 72, Processing Time 0.02 seconds

An Experimental Study on the Physical Properties of Wood Wool Board Applied Inorganic Polymer Binder (무기 폴리머 결합재를 사용한 목모 보드의 물리적 특성에 관한 실험적 연구)

  • Choi, Hae-Young;Park, Dong-Cheol;Yang, Wan-Hee;Lee, Se-Hyun;Song, Tae-Hyup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.853-856
    • /
    • 2006
  • It is known that cement production not only consumes large amount of energy but also contributes substantially to the green house gas emission. Therefore, there is a demand to develope a new technology to produce energy efficient and environmental conscious cements. The most recent, wood wool ceramic board is being applied in various building material field, for example thermal insulating and acoustic absorption material. This paper focused on improvement of the physical properties for wood wool ceramic board applied inorganic polymer binder. As the result of this experiment, what we could obtain better wood wool ceramic board's properties such as density, water contests, water resistance and band strength, was 0.46, $10{\sim}12%$, 1.9% and $40kgf/cm^2$. This result can be applicable to commercial wood wool ceramic board.

  • PDF

A Study on Fabrication and Characterization of Inorganic Insulation Material by Hydrothermal Synthesis Method (1) (수열합성법을 이용한 무기계 단열소재 제조방법 및 특성에 관한 연구 (1))

  • Seo, Sung-Kwan;Chu, Yong-Sik;Lee, Jong-Kyu;Song, Hun;Park, Jae-Wan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.219-224
    • /
    • 2013
  • In this study, the inorganic insulating material was fabricated with quartzite, ordinary portland cement(OPC), lime and anhydrous gypsum. After characteristic analysis of slurry, the optimum mixing ratio was derived with different $CaO/SiO_2$ mole ratio. Based on derived mixing ratio, the inorganic insulating material was fabricated at different water content and hydrothermal synthesis conditions. Specific gravity was $0.26g/cm^3$, compressive strength was 0.4 MPa, and thermal conductivity was 0.064 W/mK. This properties were enhanced performance of conventional ALC (Autoclaved Lightweight Concrete). And it can replace organic insulation with harmless inorganic insulation through continues research and development.

Numerical simulation of hollow steel profiles for lightweight concrete sandwich panels

  • Brunesi, E.;Nascimbene, R.;Deyanova, M.;Pagani, C.;Zambelli, S.
    • Computers and Concrete
    • /
    • v.15 no.6
    • /
    • pp.951-972
    • /
    • 2015
  • The focus of the present study is to investigate both local and global behaviour of a precast concrete sandwich panel. The selected prototype consists of two reinforced concrete layers coupled by a system of cold-drawn steel profiles and one intermediate layer of insulating material. High-definition nonlinear finite element (FE) models, based on 3D brick and 2D interface elements, are used to assess the capacity of this technology under shear, tension and compression. Geometrical nonlinearities are accounted via large displacement-large strain formulation, whilst material nonlinearities are included, in the series of simulations, by means of Von Mises yielding criterion for steel elements and a classical total strain crack model for concrete; a bond-slip constitutive law is additionally adopted to reproduce steel profile-concrete layer interaction. First, constitutive models are calibrated on the basis of preliminary pull and pull-out tests for steel and concrete, respectively. Geometrically and materially nonlinear FE simulations are performed, in compliance with experimental tests, to validate the proposed modeling approach and characterize shear, compressive and tensile response of this system, in terms of global capacity curves and local stress/strain distributions. Based on these experimental and numerical data, the structural performance is then quantified under various loading conditions, aimed to reproduce the behaviour of this solution during production, transport, construction and service conditions.

Influence of Rheological Properties of Lightweight Foamed Concrete on Preventing Foam Collapse (경량 기포 콘크리트의 레올로지 특성이 소포억제에 미치는 영향)

  • Lee, Hyang-Sun;Jeon, Jong-Woon;Jo, Mujin;Kee, Seong-Hoon;Han, Dongyeop
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.304-310
    • /
    • 2018
  • The aim of the research is to provide possibility of quality controlling by rheological properties for lightweight foamed concrete. The lightweight foamed concrete achieves its low density by containing air bubbles (foam) produced during the mixing process. Therefore, containing foamed volume during setting period is critical for the securing the performance as an insulating material. In this research, regarding foam collapse during the setting period, rheolgocial properties of fresh state lightweight foamed concrete were assessed to get its relationship with volume stability, or foam stability. For the experiment regarding foaming factors including mixing time, mix design of contents for materials, rheological properties of fresh state lightweight foamed concrete were tested with its density and settling depth. Based on the settling depth with various factors, relationship with rheological properties was analyzed, and especially, close relationship of plastic viscosity and settling depth was found. Therefore, from the results of this research, it is considered to contribute on suggesting a new approach of quality controlling for lightweight foamed concrete using rheological test method.

Predicting the moment capacity of RC slabs with insulation materials exposed to fire by ANN

  • Erdem, Hakan
    • Structural Engineering and Mechanics
    • /
    • v.64 no.3
    • /
    • pp.339-346
    • /
    • 2017
  • Slabs prevent harmful effects of fire that may occur in any floor. However, it is necessary to protect the slabs from fire. Insulation materials may be appropriate to protect reinforced concrete (RC) slab from elevated temperature. In the present study, a model has been developed in artificial neural network (ANN) to predict the moment capacity ($M_r$) of RC slabs exposed to fire with insulation material. 672 data were obtained for ANN model through author's prepared program. Input layer in model consisted of seven input parameters; such as effective depth (d), ratio of d'/d, thermal conductivity coefficient ($k_{insulation}$), insulation materials thickness ($L_{insulation}$), reinforcement area ($A_{st}$), fire exposure time ($t_{\exp}$), and concrete compressive strength ($f_c$). The predicted $M_r$ by ANN was consistent with the obtained $M_r$ by author. It is proposed to ease computational complexity in determining $M_r$ using ANN. The effects of using insulation material on the moment capacity in RC slabs were also investigated. Insulating material with low thermal conductivity has been found to be more effective for durability to high temperature.

A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage (청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구)

  • 이석건;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.1
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF

Fundamental Study on Estimating Compressive Strength and Physical Characteristic of Heat insulation Lightweight Mortar With Foam Agent (기포제 혼입 단열형 경량모르타르의 물리적 특성 및 압축강도 추정에 관한 기초적 연구)

  • Min, Tae-Beom;Woo, Young-Je;Lee, han-Seung
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.89-96
    • /
    • 2010
  • In comparison with ordinary or heavy-weight concrete, light-weight air void concrete has the good aspects in optimizing super tall structure systems for the process of design considering wind load and seismic load by lightening total dead load of buildings and reducing natural resources used. Light-weight air void concrete has excellent properties of heat and sound insulating due to its high amount porosity of air voids. So, it has been used as partition walls and the floor of Ondol which is the traditional Korean floor heating system. Under the condition of which the supply of light-weight aggregates are limited, the development of light-weight concrete using air voids is highly required in the aspects of reduced manufacturing prices and mass production. In this study, we investigated the physical properties and thermal behaviors of specimens that applied different mixing ratios of foaming agent to evaluate the possibility of use in the structural elements. We proposed the estimating equation for compressive strength of each mix having different ratio of foaming agent. We also confirmed that the density of cement matrix is decreased as the mixing amount of foaming agent increase up to 0.6% of foaming agent mixing ratio which was observed by SEM. Based on porosity and compressive strength of control mortar without foaming agent, we built the estimating equations of compressive strength for mortars with foaming agent. The upper limit of use in foaming agent is about 0.6% of the binder amount. Each air void is independent, and size of voids range from 50 to $100{\mu}m$.

The Experimental Study on the Impact Sound Insulation Floors due to Waste Tire Chip (폐타이어 칩의 바닥충격음 차단성능에 관한 실험적 연구)

  • 양관섭;이세현;김홍열;김승민
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.477-484
    • /
    • 1999
  • This study aims to present proper thickness of resilient mount and pattern of chips for the improvement of impact sound isolation. To achieve this aim, field tests were performed to evaluate the performance of impact sound isolation of pilot samples using waste tire chips against light and heavy-weight impacter, which samples were installed over concrete slabs of an apartment housing. In this study, the experiments were performed by the impact sound level of floors in KS F 2810 "Method for field measurement of floor impact level". As results, a flooring structure using waste tire chips as a resilient mount, with no relation to chip's types, has enhanced performance by 1~2 degree in light impact sound isolation, while it has improvement in heavy impact sound isolation. And fiber-type chips have better performance than granule-type ones when they overlaid concrete slab with 15~20 mm of thickness. For the improvement of impact sound isolation, it is recommended that insulating materials should be applied at joints between floating floors and walls, or floating floors and a doorframes, and also waterproof papers should be used for the effective thickness of resilient mount.ent mount.

  • PDF

Effects of Different Lightweight Functional Fillers for Use in Cementitious Composites

  • Hanif, Asad;Lu, Zeyu;Cheng, Yu;Diao, Su;Li, Zongjin
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.99-113
    • /
    • 2017
  • The effects of different lightweight functional fillers on the properties of cement-based composites are investigated in this study. The fillers include fly ash cenospheres (FACs) and glass micro-spheres (GMS15 and GMS38) in various proportions. The developed composites were tested for compressive, flexural and tensile strengths at 10 and 28-day ages. The results indicated that both FACs and GMS38 are excellent candidates for producing strong lightweight composites. However, incorporation of GMS15 resulted in much lower specific strength values (only up to $13.64kPa/kg\;m^3$) due to its thinner shell thickness and lower isostatic crushing strength value (2.07 MPa). Microstructural analyses further revealed that GMS38 and GMS15 were better suited for thermal insulating applications. However, higher weight fraction of the fillers in composites leads to increased porosity which might be detrimental to their strength development.

Experimental investigation of the effect of the addition of Aerosil 200 nanoparticles on the water absorption of polymer concrete

  • A.M. Fattahi;Babak Safaei;Elham Moaddab;Zahra Pezeshki
    • Advances in nano research
    • /
    • v.14 no.1
    • /
    • pp.81-92
    • /
    • 2023
  • In this work, the effect of the addition of Aerosil 200, an insulating resin applied in many industries, on the water absorption of cement plast mixture has been experimentally evaluated. First, the preparation stages of cement plast mixture was evaluated based on corresponding standards and then, the effect of the addition of Aerosil 200 nanoparticles (NPs) to cement plast mixtures with sand weight percentage range of 0-0.1% on the variation of water absorption properties was evaluated based on National Standard Institution of Iran 20185 for Concrete Flooring Blocks - Requirements and Test Procedures. Based on the obtained results, it could be found that excessive addition of NPs did not affect the physical properties of the final product. Water absorption percentage was increased in the weight percentage of cement. By the increase of the amount of Aerosil 200 NPs in the prepared cement plast mixture, the percentage of water absorption in weight percentage of sand was decreased. Cement plast with NPs presented significantly lower water absorption than that without NPs.