Study on the electrical and mechanical properties of insulating paper (절연지의 기계적 및 전기적 물성에 대한 연구)

  • 엄승욱;김귀열
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.413-417
    • /
    • 1995
  • In order to elucidate the electrical and mechanical properties of insulating paper, it is desirable to study the performances of tensile strength, dielectric constant, dielectric strength. In this work, we constructed the characteristics depending on change of fabrication condition, and these specimens were manufactured by hot press method. As a result, tensile strength was about 75MPa and breakdown was above 5 kV/mm at the minimum value.

  • PDF

Deterioration Phenomene of Insulating Papers Caused by Moisture Absorbed (흡습에 인한 절연지의 열화현상)

  • 성영권;백영학;김용주;이덕출;라명원
    • 전기의세계
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 1971
  • Using insulating paper (cellophan), we measured the influences of moisture abosrbed for electrical properties i.e. V.I curves which result in deteriorating due to the moisture alsorbed is related to electrical properties Considerally due to the electrolytic effects of moisture involved cellulose Gel structure, we obtained also an evaluation method of deterioration rate Caused by the moisture absorbed in insulating papers.

  • PDF

Concrete Strength Characteristic of the Insulating Gang Form for Mock-Up Members (Mock-up 부재에 적용한 단열 갱폼의 콘크리트 강도 특성)

  • Kim, Ji-Hun;Nam, Kyung-Yong;Lim, Nam-GI;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.67-68
    • /
    • 2013
  • In this paper, the compressive strength of an insulating gang form member, which was developed to improve the cold weather concreting quality, and a general gang form member was measured by age to examine the compressive strength characteristics of the two members compared with the standard curing test piece.

  • PDF

The Effects of Heat Transfer Characteristics of Fibers on the Warm/Cool Touch of Insulating Nonwovens (섬유의 열전달 특성이 보온용 부직포의 접촉온냉감에 미치는 영향)

  • Kim, Hee-Sook
    • Korean Journal of Human Ecology
    • /
    • v.8 no.1
    • /
    • pp.125-134
    • /
    • 1999
  • The purpose of this study was to investigate the effects of heat transfer characteristics of fibers on the Qmax of insulating nonwovens. The effects of fiber type, moisture content, washing cycles on the Qmax were observed. The correlations between Qmax measured by KES-F7 system and subjective warm/cool touch perception test was analyzed. The results obtained were as followed: 1. Heat transfer characteristics of fibers effected on the Qmax of insulating nonwovens. 2. Moisture transport properties of fibers effected considerably on the Qmax of nonwovens and the increasing rate of Qmax by increasing moisture content was much higher at wool than polyester. 3. As a result of subjective perception test, subjective warm/cool touch and wettness of wool nonwoven was increased obviously by increasing moisture content. 4. At the same moisture content, wool nonwoven showed higher subjective cool touch and wetness than polyester. 5. In the physical properties of nonwovens, thickness was the most effective factor on the Qmax of insulating nonwovens.

  • PDF

A Study on the Streaming Electrification in the Super-high Voltage Model Transformer (초고압 대용량 모델변압기의 유동대전 현상에 관한 연구(전압무인가))

  • 이덕출;박재윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.619-625
    • /
    • 1991
  • Phenomena of streaming electrification of insulting oil(T.O) is studied where the oil is contacted with solid insulating materials when it is pumped through a circulating system in a large power transformer. The leakage current, the electrical potential at the neutral terminal point of the transformer and the surface electrical potential of the oil are investigated. And the leakage current from the neutral terminal point is measured as a function of a bias polarity applied to a transformer case to investigate the polarty of ion which is absorbed in the case at the interface between the case and oil. As a result, it is found that insulating materials, and it is suggested that the leakage current is the sum of the relaxation current by positive charge from insulating oil to the neutral terminal point and by electrification current from negative charge electrified by the contact with solid insulating materials.

  • PDF

A Fundamental Study on the Effectiveness of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (Focused on the Slab) (내한제 및 단열거푸집에 의한 한중콘크리트 시공의 효율화에 관한 기초적 연구 (슬래브를 중심으로))

  • Kim, Kyoung-Min;Won, Cheol;Hong, Sang-Hee;Kim, Gi-Cheol;Oh, Sun-Kyo;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.913-918
    • /
    • 2001
  • This paper investigates insulating effects and strength properties of concrete under cold climate carrying out the experiment with insulating forms on the slab member. According to test results, under $-10^{\circ}C$ of outer temperature, the surface of concrete exposed to outer temperature goes below zero after 10hours since exposed. And, the surface of concrete covered with vinyl and blanket goes below zero after 42hours. However, the surface of concrete covered with insulating materials such as polystyrene foam does not drop below zero until 55hours. And, according to coring sample strength test, compressive strength cured with insulation shows much higher strength than no insulation curing condition and vinyl and blanket curing condition.

  • PDF

An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구)

  • 김경민;손성운;김기철;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.663-668
    • /
    • 2002
  • In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

  • PDF

The Thickness Dependence of Edge Effect in Thin Insulating Films

  • Song Jeong-Myen;Moon Byung-Moo;Sung Yung-Kwon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.4
    • /
    • pp.13-17
    • /
    • 2003
  • This paper deals with the edge effect in thin insulating films, focusing on their dependence on film thickness. The finding is that the electric field is lowered at the edge as the film thickness is reduced, which, in turn, is closely related to dielectric breakdown voltage. In order to analyze this phenomenon, a simple capacitor model is introduced with which dependence of dielectric breakdown voltage around the electrode edge on the film thickness is explained. Due to analytical difficulty to get the expression of electrical field strength at the edge, an equivalent circuit approach is used to find the voltage expression first and then the electric field expression using it. The relation gets to an agreement with the experimental findings shown in the paper. This outcome may be extended to solve similar problems in multi-layer insulating films.

A Study on the Tree Growth by Interface Type of XLPE (XLPE의 계면형태에 따른 트리성장에 관한 연구)

  • 김철운;김영민;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.111-115
    • /
    • 1997
  • There exists a interface among the different kinds of materials in the solid insulating ones, which effects on the insulating capability heavily. The insulating construction has been developed for each usages and take themselves into several sorts. The conjunction between CV cables have the electrical weakness of solidity and solid interface, so they were focused at the long distance-line. To this background, it is very important to get the information on the interface influencing on the insulating capability of cable and to observe its procedure. In this paper, the interface was made artificially to research the effect owing to the toughness of interface, which results in the aging and treeing proceeding was observed. The polyethylen, as is generally using for the cable, was taken in this research.

  • PDF

Electric field distribution according to surface roughness of insulating paper (표면 거침도에 따른 종이절연지의 전계분포)

  • Park, Hyoung-Jun;Kim, Weon-Jong;Shin, Jong-Yeol;Kim, Soo-Won;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.323-326
    • /
    • 2004
  • The this paper is describing about the electric field distribution due to the roughness in Aramid insulating paper for electric machine. The insulting and pressboard paper have been used at electric insulating of traction motor and generators. There was a change investigation of the electric field distribution according to the roughness of specimen by simulation program of Electro. We studied the electric field distribution using boundary element method for Aramid insulator. We find out an optimal condition in insulating paper of electric machine.

  • PDF