• 제목/요약/키워드: Instantaneous reactive power

검색결과 103건 처리시간 0.029초

무효전력을 이용한 영구자석 동기전동기의 위치 및 속도 센서리스 제어 (Sensorless Vector Control for PMSM Using Instantaneous Reactive Power)

  • 진창언;한윤석;신재화;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1053-1055
    • /
    • 2000
  • This paper describes a new approach to estimating permanent magnet synchronous motor(PMSM) speed and position from measured terminal voltages and currents for speed-sensorless vector control. The proposed system is based on observing the instantaneous reactive power of the motor. The described technique is very simple and robust to variations of motor parameters. The new approach is not dependent upon the value of the stator resistance. Also, MRAS schemes are chosen for determining the adaptive law for the speed and the position estimator. The effectiveness is verified by simulation.

  • PDF

초기위치 추정 및 파라미터 계측을 선행하여 순시무효전력을 이용한 IPMSM의 센서리스 제어 (Sensorless Control of IPMS on an Instantaneous Reactive Power Preceding Initial Position Estimation and Parameter Measurement)

  • 김원석;정우택;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.207-209
    • /
    • 2005
  • Recently, the use of IPMSM is coming to be active, in many industrial applications. In sensorless drive of IPMSM, it is important to know the exact information of the initial rotor position, because the wrong estimation of the initial rotor position brings about the decrease of the starting torque, or a temporary reverse revolution, In addition, PMSM is necessary to use the accurate information of the inductance for the precise torque control owing to the reluctance torque. In this paper presents initial rotor position estimation method and, measure method of the each-axis inductance. And to minimize the speed estimations error, the estimated speeds are compensated by using an instantaneous reactive power in synchronously rotating reference frame.

  • PDF

무효전력을 이용한 영구자석 동기전동기의 위치 및 속도 센서리스 제어 (Sensorless Vector Control for PMSM Using Instantaneous Reactive Power)

  • 진창언;한윤석;신재화;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.384-386
    • /
    • 2000
  • This paper describes a new approach to estimating permanent magnet synchronous motor(PMSM) speed and position from measured terminal voltages and currents for speed-sensorless vector control. The proposed system is based on observing the instantaneous reactive power of the motor. The described technique is very simple and robust to variations of motor parameters. The new approach is not dependent upon the value of the stator resistance. Also, MRAS schemes are chosen for determining the adaptive law for the speed and the position estimator. The effectiveness is verified by the experimental results.

  • PDF

파라미터 동정과 순시무효전력을 이용한 IPMSM 센서리스 제어 (IPMSM Sensorless control Based on Parameter Identification and Instantaneous Reactive Power)

  • 김원석;이형;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.214-216
    • /
    • 2005
  • IPMSM is necessary to use the accurate values of the inductance for the precise torque control, because of using the reluctance torque of the IPM. This paper presents method to uses the hysteresis loop inclination of the flux and current measured by applying the positive and negative voltage pulse alternately on the each-axis. Moreover, presents algorithm for speed sensorless control based on parameter identification and instantaneous reactive power.

  • PDF

Design and Implementation of Instantaneous Power Estimation Algorithm for Unified Power Conditioner

  • S., Sindhu;M.R., Sindhu;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.815-826
    • /
    • 2019
  • This paper discusses a simple control approach for a Unified Power Conditioner (UPC) system to achieve power quality compensation at the point of common coupling in distribution systems. The proposed Instantaneous Power Estimation Algorithm (IPEA) for shunt and series active power filters uses a simple mathematical concept that reduces the complexity in the design of the controller. The performance of a UPC is verified with a system subjected to voltage distortions, sags/swells and unbalanced loads using MATLAB/SIMULINK. The simulation study shows that a UPC with the proposed control algorithm can effectively compensate for voltage and current harmonics, unbalance and reactive power. The control algorithm is experimentally implemented using dSPACE DS1104 and its effectiveness has been verified.

무효전력을 이용한 영구자석 동기전동기의 새로운 센서리스 제어 (New Sensorless Control of PMSM using Reactive Power)

  • 한윤석;최정수;김영석;신재화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.237-239
    • /
    • 2001
  • This paper presents a new speed sensorless control method of permanent magnet synchronous motors based on instantaneous reactive power. The proposed system is constructed in a synchronously rotating reference frame and is very simple. The new approach is not dependent upon the stator resistance, nor is it affected by mechanical motor parameters. The effectiveness of the proposed system is confirmed by the simulation results.

  • PDF

소프트 절환이 가능한 계통 연계형 CTTS 시스템 구성에 관한 연구 (A Study on System Configuration of Grid-connected CTTS System with Soft Switching)

  • 이형묵;양지훈;이정환;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.361-368
    • /
    • 2018
  • This paper proposes a grid - connected CTTS system that can be soft switched to meet the government's effective resource allocation policy for emergency generator. In order to eliminate the system instability caused by the large inrush current generation in the system switching, a new virtual rotation coordinate method for the dissimilar power source is proposed. The proposed virtual rotation coordinate method improves the voltage detection accuracy of the voltage difference of the dissimilar power supply, and it is proved that the synchronous switching characteristic is excellent. In addition, zero current and system stabilization can be achieved by realizing zero current when blocking CTTS with instantaneous reactive power control. Simulation was carried out to verify the validity of the proposed method, and the 500[kVA] system was fabricated and verified to demonstrate the superiority of the proposed method.

Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance

  • Han, Daesu;Park, Yonggyun;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.246-247
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions, and torque pulsation. The control algorithm having zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive power. Combination of these two control algorithms depending on the operating requirements and depth of grid unbalance presents most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system. The proposed control algorithms are verified through transient response in the simulation.

  • PDF

회전좌표계를 이용한 단상 하이브리드형 능동 전력필터 (Single-Phase Hybrid Active Power Filter Using Rotating Reference Frame)

  • 김진선;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권8호
    • /
    • pp.377-386
    • /
    • 2005
  • This paper presents the control algorithm of single-phase hybrid active power filter for the compensation of harmonic current components in nonlinear R-L load with passive active Power filters. To construct two phase system, an imaginary second phase was made. In this proposed method, the new signal which is the delayed through the filtering by the phase-delay property of low-pass filter is used as the secondary phase. Because two-phases have the different phase, the instantaneous calculation of harmonic current is possible. In this paper, a reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency, not applying to instantaneous reactive power theory which has been used with the existing fixed reference frames In order to verify the validities of the proposed control methods, experiments are carried out with the prototypes of single-phase hybrid active power filter.

3상 계통에서 전류/전압과 순시전력간의 맵핑이론 (The Mapping Theory between Current/Voltage and Instantaneous Powers in Three-phase Systems)

  • 김효성;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.228-232
    • /
    • 1997
  • The relation between instantaneous active/reactive powers and currents is defined by voltage mapping matrix in three-phase four-wire systems. Control strategies for an active filter without energy storage components are proposed on the basis of mapping matrices. It can compensate for the zero-sequence current, irrespectively of whether or not a zero-sequence voltage exists in a three-phase four-wire system.

  • PDF