• Title/Summary/Keyword: Instantaneous Frequency Measurement

Search Result 45, Processing Time 0.021 seconds

The Analysis of Mental Stress using Time-Frequency Analysis of Heart Rate Variability Signal (심박변동 신호의 시-주파수 분석을 이용한 스트레스 분석에 관한 연구)

  • Seong Hong Mo;Lee Joo Sung;Kim Wuon Shik;Lee Hyun Sook;Youn Young Ro;Shin Tae Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.581-587
    • /
    • 2004
  • Conventional power spectrum methods based on FFT, AR method are not appropriate for analyzing biomedical signals whose spectral characteristics change rapidly. On the other hand, time-frequency analysis has more desirable characteristics of a time-varying spectrum. In this study, we investigated the spectral components of heart rate variability(HRV) in time-frequency domain using time frequency analysis methods. In the various time-frequency kernels functions, we studied the suitable kernels for the analysis of HRV using synthetic HRV signals. First, we evaluated the time/frequency resolution and cross term reduction of various kernel functions. Then, from the instantaneous frequency, obtained from time-frequency distribution, the method extracting frequency components of HRV was proposed. Subjects were 17 healthy young men. A coin-stacking task was used to induce mental stress. For each subjects, the experiment time was 3 minutes. Electrocardiogram, measured during the experiment, was analyzed after converted to HRV signal. In the results, emotional stress of subjects produced an increase in sympathetic activity. Sympathetic activation was responsible for the significant increase in the LF/HF ratio. Subjects were divided into two groups with task ability. Subjects who have higher mental stress have lack of task ability.

PIV Measurement of Circular Cylinder Wake Using Vortex Tracking Phase-Average Technique (와추적 위상평균 기법을 이용한 원주후류의 PIV측정)

  • Kim, Gyeong-Cheon;Yun, Sang-Yeol;Kim, Sang-Gi;Bu, Jeong-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.7
    • /
    • pp.915-922
    • /
    • 2001
  • A new phase-average technique using instantaneous velocity fields obtained by a PIV method has been developed. The technique tracks vorticity centers and estimates the value of circulation for a chosen domain. The locations of vortex-centers and the magnitudes of circulation are matched together then showing a sine wave feature due to the periodic vortex shedding from the circular cylinder. Ensemble averaged and phase averaged velocity fields are successfully measured for the circular cylinder wake where Reynolds number is 3900 based on free stream velocity and cylinder diameter. The convection velocities of the vortices center and the vortex shedding frequency were measured by a single hot-wire probe.

Shock-Wave Oscillation in a Supersonic Diffuser -Displacement Measurement of Mormal Shock-Wave- (초음속 디퓨져에서 충격파의 진동 (1) -수직충격파의 순간변위 측정-)

  • 김희동;엄용균;권순범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.933-945
    • /
    • 1994
  • A shock-wave in a supersonic flow can be theoretically determined by a given pressure ratio at upstream and downstream flowfields, and then the obtained shock-wave is stable in its position. Under the practical situation in which the shock-wave interacts with the boundary layer along a solid wall, it cannot, however, be stable even for the given pressure ratio being independent of time and oscillates around a time-mean position. In the present study, oscillations of a weak normal shock-wave in a supersonic diffuser were measured by a Line Image Sensor(LIS), and they were compared with the data of the wall pressure fluctuations at the foot of the shock-wave interacting with the wall boundary layer. LIS was incorporated into a conventional schlieren optical system and its signal, instantaneous displacement of the interacting shock-wave, was analyzed by a statistical method. The results show that the displacement of an oscillating shock-wave increase with the upstream Mach number and the dominant frequency components of the oscillating shock-wave are below 200 Hz. Measurements indicated that shock-wave oscillations may not entirely be caused by the boundary layer separation. The statistical properties of oscillations appeared, however, to be significantly affected by shock-induced separation of turbulent boundary layer.

Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings (배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.

Performance Characteristics of a V-type Probe Developed for Wall Vorticity Measurement (벽와도 측정을 위하여 개발된 V형 열선 프로브의 성능특성)

  • Kim, Seong-Uk;Ryu, Sang-Jin;Yu, Jeong-Yeol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.514-522
    • /
    • 2001
  • In order to investigate the relation between wall vorticity and streamwise velocity fluctuations in a turbulent boundary layer, a wall vorticity probe has been developed, which consists of two hot-wires on the wall aligned in V configuration. Although the measured intensity of spanwise wall vorticity fluctuations is somewhat lower than previous results, the intensity of streamwise wall vorticity fluctuations is in good agreement with them. It has been shown that the measured intensity of spanwise wall vorticity fluctuations is affected by transverse length of the wall vorticity probe. Instantaneous streamwise and spanwise wall vorticity fluctuations are compared with the results of DNS. Probability density function of spanwise wall vorticity fluctuations shows good agreement with previous results and is different from that of streamwise wall vorticity fluctuations. Energy spectrum of streamwisw wall vorticity fluctuations is lower than that of spanwise wall vorticity fluctuations in low frequency region.

UE Measurement Based Compressed Mode in WCDMA (WCDMA 시스템에서 단말 측정에 의한 압축 모드 방법)

  • 김선명;장원학;조영종;임재성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.814-827
    • /
    • 2004
  • The compressed mode is used to perform inter-frequency and inter-system handover in WCDMA. The instantaneous transmit power is increased in the compressed frame in order to keep the QoS(Quality of Service) unaffected by the reduced processing gain. Furthermore, since the inner loop power control is not active during the transmission gap and the effect of interleaving is decreased, a higher Eb/No target is required, which directly affects the system performance. Due to the impact on performance, the compressed mode should be activated by the RNC(Radio Network Controller) only when there is real need to execute an inter-frequency or inter-system handover. However, 3GPP does not define the method that decides the compressed mode activation. In order to reduce performance degradation, there is need the decision method. In this paper, we consider a combined cell structure in which some neighbor cells have a frequency the same as serving cell and the others have a different frequency or system. Under consideration, we analyze the effect of the compressed mode on the WCDMA forward link performance. In order to avoid performance degradation, we propose an UE(User Equipment) measurement method that can restrict the activation area of the compressed mode of UE that does not need it and evaluate its performance by simulations. Analytical results show that the use of the compressed mode affects the performance degradation. And simulation results show that proposed method leads to better performance.

A Study on the Design of Digital Frequency Discriminator with 3-Channel Delay Lines (3채널 지연선을 가진 디지털주파수판별기의 설계에 관한 연구)

  • Kim, Seung-Woo;Choi, Jae-In;Chin, Hui-cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.44-52
    • /
    • 2017
  • In this paper, we propose a DFD (Digital Frequency Discriminator) design that has better frequency discrimination and a smaller size. Electronic warfare equipment can analyze different types of radar signal such as those based on Frequency, Pulse Width, Time Of Arrival, Pulse Amplitude, Angle Of Arrival and Modulation On Pulse. In order for electronic warfare equipment to analyze radar signals with a narrow pulse width (less than 100ns), they need to have a special receiver structure called IFM (Instantaneous Frequency Measurement). The DFD (Digital Frequency Discriminator) is usually used for the IFM. Because the existing DFDs are composed of separate circuit devices, they are bulky, heavy, and expensive. To remedy these shortcomings, we use a three delay line ($1{\lambda}$, $4{\lambda}$, $16{\lambda}$) in the DFD, instead of the four delay line ($1{\lambda}$, $4{\lambda}$, $16{\lambda}$, $64{\lambda}$) generally used in the existing DFDs, and apply the microwave integrated circuit method. To enhance the frequency discrimination, we detect the pulse amplitude and perform temperature correction. The proposed DFD has a frequency discrimination error of less than 1.5MHz, affording it better performance than imported DFDs.

Gauss-Newton Based Emitter Location Method Using Successive TDOA and FDOA Measurements (연속 측정된 TDOA와 FDOA를 이용한 Gauss-Newton 기법 기반의 신호원 위치추정 방법)

  • Kim, Yong-Hee;Kim, Dong-Gyu;Han, Jin-Woo;Song, Kyu-Ha;Kim, Hyoung-Nam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.76-84
    • /
    • 2013
  • In the passive emitter localization using instantaneous TDOA (time difference of arrival) and FDOA (frequency difference of arrival) measurements, the estimation accuracy can be improved by collecting additional measurements. To achieve this goal, it is required to increase the number of the sensors. However, in electronic warfare environment, a large number of sensors cause the loss of military strength due to high probability of intercept. Also, the additional processes should be considered such as the data link and the clock synchronization between the sensors. Hence, in this paper, the passive localization of a stationary emitter is presented by using the successive TDOA and FDOA measurements from two moving sensors. In this case, since an independent pair of sensors is added in the data set at every instant of measurement, each pair of sensors does not share the common reference sensor. Therefore, the QCLS (quadratic correction least squares) methods cannot be applied, in which all pairs of sensor should include the common reference sensor. For this reason, a Gauss-Newton algorithm is adopted to solve the non-linear least square problem. In addition, to show the performance of the proposed method, we compare the RMSE (root mean square error) of the estimates with CRLB (Cramer-Rao lower bound) and derived the CEP (circular error probable) planes to analyze the expected estimation performance on the 2-dimensional space.

A study on measurement of physical parameters using electromagnetic wave of the compacted saturated soil (고주파수 전자기파를 이용한 압밀 포화토 물성치 측정을 위한 연구)

  • Kim, Man-Il;Kim, Hyoung-Soo;Suk, Hee-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.354-361
    • /
    • 2005
  • Physical parameters such as porosity and effective porosity are important physical parameters that determine the transfer and movement of water and solutes in porous media. Various methods of determining these parameters have been developed, with varying degrees of accuracy and applicability. Most of the existing methods produce static results. They do not produce instantaneous and real time of porosity and effective porosity in a porous media. In this study, a new permittivity method called Frequency Domain Reflectometry with Vector analyzer (FDR-V) is proposed to determine the porosity and effective porosity of some sand samples in the laboratory. The advantage of the FDR-V method is that it instantaneously determines the temporal variation of dielectric constants of porous media. Then, the porosity and the effective porosity of porous media are computed using well established empirical equations. Results obtained from the FDR-V method compared favorably with results from other permittivity methods such as gravimetric, injection and replacement tests. The ratio of effective porosity to porosity was $85{\sim}92%$, when FDR-V was used. This value compared favourably with 90%, which has been usually quoted in previous studies. Considering the convenience and its applicability, the measurement system of FDR-V permittivity holds a great potential in porous media and contaminant transport studies.

  • PDF

Dynamic Characteristics of Pressure Propagation According to Boundary Condition Changes in a Transmission Line (경계조건변화에 따른 동력전달관로의 동특성)

  • 나기대;유영태;김지환
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.75-82
    • /
    • 2002
  • Design for a quiet operation of fluid power system requires the understanding of noise and vibration characteristics of the system. It's not easy to analyze noise problem in hydraulic cylinder used in typical actuator Because they've got complex fluid dynamics. One of the fundamental problems associated with the hydraulic system is the pulsating flow in pipe lines, which can be tackled by the analysis under simplifying assumptions. The present study focuses on theoretic analysis and experimental study on the dynamics of laminar pulsating flow in a circular pipe. We analyze the propagation characteristics of the pressure pulse within a hydraulic pipe line taking into account the pulsating flow frequency variation. We also measure instantaneous pressure pulses within pipe line to identify the transfer functions. We conduct series of experiments to investigate the propagation characteristics of pressure pulse for various pressure of pulsating flow. The working fluid of the present study is ISO VG46 and the temperature ranges from 20 to $60^{\circ}$ with normal pressure at 4000kPa. The flow rate is measured by using an ultrasonic flow meter. Pressures at fixed upstream and downstream positions are measured concurrently. The electric signals of the pressure sensor are stored and analyzed using a system analyzer(PKE 983 series). The frequency is varied in the range of 10~500Hz. The Reynolds number is kept below 2,000. In the present study, boundary condition was varied by installing a surge tank and an orifice at the end of pipe. Experimental and theoretical results were compared each other under various boundary conditions.