• Title/Summary/Keyword: Installation time

Search Result 1,992, Processing Time 0.031 seconds

Improvement of the PVC Window Frame Installation Method Integrated with Gangform and Field Applicability Analysis

  • Choi, Hyo-Sung;Lee, Jeong-Ho;Yoo, Huyn-Seok;Kim, Young-Suk;Han, Seung-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.482-500
    • /
    • 2011
  • In apartment housing construction, window frame installation work, which is conducted after the structural framework, is very important, because its completion time directly affects the starting time of successive interior finishing works, as well as the overall construction period. Construction delays in interior finishing works might occur due to problems inherent to the conventional window frame installation method, such as the poor verticality of window frames, and the water leakage around them. The primary objective of this study is to analyze the problems of a 'Gangform integrated PVC window frame pre-installation method' based on its pilot test results. Next, this study proposes an improved conceptual model that enables the end users to enhance the field applicability of this method in terms of productivity, time, and cost. The field applicability of the proposed 'Gangform integrated PVC window frame pre-installation method' was also verified through a survey.

A Study on the Relationship to Installation Art in Deconstruction Architecture Design (해체주의 건축 디자인에서 설치미술과의 상관성에 관한 연구)

  • 김명옥
    • Korean Institute of Interior Design Journal
    • /
    • no.12
    • /
    • pp.10-17
    • /
    • 1997
  • The lastest art is being characterised by an ever active exchange between different genre. This is a study on the installation aspect in deconstruction architectured and interior design. The progressive and aggressive nature of installatation art embodies uncatagorized genre, the freedom of material application, introduction of the notion of time in space, the reversion of subject and object, the union of art and every experience, understanding of object through deconstruction, enlargement of concept of space, collage-style composition and layer technique. I can conclude that the installation aspect in Tshumi's Parc de la Villette is its call upon the audience to actively participate, the introduction of a coincidental conjunction, its challenge on the conventional idea of park and its flexibility caused by human activity and time. In Hadid's Hong Kong Peak Club the installation aspect is the application of layer technique using four enormous beams horizontally laid out on a man-made moutain. Furthermore, Libeskind's pursuit of the mental in Berlin Museum Extension through the penetration of an invisible line into a void creates a new interpretation of the role of a museum and thus relates itself to installation art. The installation aspect in Himmelblau's Vienna Roof Renovation is the literal deconstruction of the roof of an old building in the old section of Wien and the expression of time and space through the interrelationship between interior and exterior environment by the use of juxtaposition technique. Finally, I note that the installation aspect in Gehry's Santa Monica Residence is the reorganization of cheap material as a form of 'object', that creates spon-taneity, movement as well as flow of time in space and ex-hibit the double-sidedness of the visible world.

  • PDF

A Production-Installation Simulation Model of Free-Form Concrete Panels

  • Lim, Jeeyoung;Lee, Donghoon;Na, Youngju;Lim, Chaeyeon;Kim, Sunkuk
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.401-404
    • /
    • 2015
  • Demand on free-form buildings is gradually increasing, yet owing to the difficulty of production-installation work, several problems occur in the construction phase upon construction of a building, including the increased cost and construction duration, and reduced constructibility. To solve these problems, a techonology to produce FCP using a CNC(Computerized Numeric Control) machine is developed. The technology is that the information of designed free-form buildings to the CNC machine is transferred, and the transferred information is used for RTM(Rod-Type Mold, the mold shaped by back-up rods) and PCM(Phase Change Material) shaping, and the shaped RTM and PCM have the role of molds to produce FCP. Construction duration and project cost are limited in building sites, so the efficiency of processes like production-installation of FCP for application of the technology is significant. Since it is almost impossible to change the production-installation process at the construction phase when they are established, process should be deliberately decided. Therefore, the purpose of the study is to propose a production-installation simulation model of free-form concrete panels, in aspect of PCM. This paper is establishing the process for production-installation of FCP, estimating time required by each construction type and proposing a time simulation model that changes according to various constraints based on the analyses. With the time simulation model, it will be possible to build a cost model and to review the optimal construction duration and project cost.

  • PDF

Managerial Factors Influencing Dose Reduction of the Nozzle Dam Installation and Removal Tasks Inside a Steam Generator Water Chamber (증기발생기 수실 노즐댐 설치 및 제거작업의 피폭선량 저감에 영향을 주는 관리요인에 관한 연구)

  • Lee, Dhong Ha
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.559-568
    • /
    • 2017
  • Objective: The aim of this study is to investigate the effective managerial factors influencing dose reduction of the nozzle dam installation and removal tasks ranking within top 3 in viewpoint of average collective dose of nuclear power plant maintenance job. Background: International Commission on Radiation Protection (ICRP) recommended to reduce unnecessary dose and to minimize the necessary dose on the participants of maintenance job in radiation fields. Method: Seven sessions of nozzle dam installation and removal task logs yielded a multiple regression model with collective dose as a dependent variable and work time, number of participants, space doses before and after shield as independent variables. From the sessions in which a significant reduction in collective dose occurred, the effective managerial factors were elicited. Results: Work time was the most important factor contributing to collective dose reduction of nozzle dam installation and removal task. Introduction of new technology in nozzle dam design or maintenance job is the most important factor for work time reduction. Conclusion: With extended task logs and big data processing technique, the more accurate prediction model illustrating the relationship between collective dose reduction and effective managerial factors would be developed. Application: The effective managerial factors will be useful to reduce collective dose of decommissioning tasks as well as regular preventive maintenance tasks for a nuclear power plant.

Automatic setting of delay time of an occupancy sensor using an adder circuit (인체감지 센서의 시간지연 설정)

  • 정영훈;송상빈;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.162-165
    • /
    • 1998
  • A certain degree of energy saving can be possible by controlling the delay time of occupancy sensor. In this paper a control circuit is designed for automatic control of delay time setting appropriate to different situations using a digital counter, two latches and an adder. The delay time is controlled by adjusting the time constant of RC circuit through on-off control of switching devices according to adder output, which determines the base current level of switching devices. And from PSpice simulation it is verified to function properly.

  • PDF

A Study On Development Train Reach Spare Time Indicate Device At The Railway Level Crossing (철도건널목 열차도달 잔여시간 표시장치 개발 연구)

  • 박기범;장우진;최규형
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.117-124
    • /
    • 2002
  • Fixed distance control system at the railway level crossing have some problem. The problem is especially serious for high speed or low speed train. Therefore present developed device is fixed time control system. But fixed time control system haven't indicate device when train reach at the railway level crossing on alarm. This paper' result in study for train reach spare time indicate device.

  • PDF

Relations between the Perception-Rerception Time and the Phantom Phenomena on Signal Light (신호등에서의 팬텀현상과 인지반응시간의 관련성)

  • ;金容周
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.144-144
    • /
    • 1999
  • Phantom phenomena on the signal light was observed and change of perception-reaction time of the observer was measured. If phantom phenomena occurs, signal light perception- reaction time by the drivers is prolonged, the extent of which may disturb driving. Length of the perception-reaction time is affected by the luminance contrast between the turned-on and tuned-off signals. Based on the measured results, several methods to prevent phantom phenomena were suggested.

A Statistical Methodology for Evaluating the Residual Life of Water Mains (상수관로의 잔존수명 평가를 위한 통계적 방법론)

  • Park, Suwan;Choi, Chang Log;Kim, Jeong Hyun;Bae, Cheol Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.305-313
    • /
    • 2009
  • This paper provides a method for evaluating a residual life of water mains using a proportional hazard model(PHM). The survival time of individual pipe is defined as the elapsed time since installation until a break rate of individual pipe exceeds the Threshold Break Rate. A break rate of an individual pipe is estimated by using the General Pipe Break Model(GPBM). In order to use the GPBM effectively, improvement of the GPBM is presented in this paper by utilizing additional break data that is the cumulative number of pipe break of 0 for the time of installation and adjusting a value of weighting factor(WF). The residual lives and hazard ratios of the case study pipes of which the cumulative number of pipe breaks is more than one is estimated by using the estimated survival function. It is found that the average residual lives of the steel and cast iron pipes are about 25.1 and 21 years, respectively. The hazard rate of the cast iron pipes is found to be higher than the steel pipes until 20 years since installation. However, the hazard rate of the cast iron pipes become lower than the hazard rates of the steel pipes after 20 years since installation.

A Study on the Emission Characteristics and Prediction of Volatile Organic Compounds from Floor and Furniture

  • Pang, Seung-Ki;Sohn, Jang-Yeul;Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.89-98
    • /
    • 2005
  • In this study, indoor VOCs concentration emitted from floor and furniture was measured after the installation of floor and furniture in a real residence. With the measured data, prediction method and predication equations for indoor concentration of each VOCs and BTEX were developed. The following conclusions were drawn from this study. First, according to the predicted results of concentration decrease of BTEX (benzene, toluene, ethylbenzene, m,p,o-xylene) after the installation of floor in a real residence, prediction equation can be expressed using exponential function. Second, in case of floor, more reliable prediction equation can be obtained by using cumulative value of indoor concentration than by using just hourly measured value directly. Indoor concentration of benzene can be expressed as $y=408.52(1­e^{-00031{\times}time})$ with $R^2$ of 0.94 which is significantly high value. Third, toluene showed the highest concentration in case of furniture installation indoors, and it needed the longest time for concentration decrease. However, other substances except toluene showed constant concentration throughout the measurement period. Fourth, in case of furniture installation indoors, prediction equation of toluene concentration decrease is estimated to be $y= 3616.3{\times}e^{(-0.1091{\times}time)}+513.96{\times}e^{(-0.0006{\times}time)}\;with\; R^2$ of 0.95 which is significantly high value.

A study on Characteristics of Installation object Appeared in Interior of contemporary Commercial Space (현대 상업공간 실내에 나타난 설치적 오브제의 표현특성에 관한 연구)

  • Kim, Ki-Young;Kim, Moon-Duck
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.203-208
    • /
    • 2008
  • Installation art in 20th century shows an expanded trend as a result of material, time, or spatial expansion of subject, therefore subjects could be either materials or non-materials. This trend says that three elements-objet, space, and spectator-is inseparable essence of installation art. Nowadays, the borderline between installation art and everyday human life is getting indistinctive, and both Installation art and human life are becoming a part of another. By adapting the flexibility of installation art into the interior space, more interaction could happen, therefore, people will recognize spatial and visual character of Interior space as a visually satisfying Installed object. The main goal of this study is to understand changing of spatial composition in consequence of expressional variety as a result of dispersion of spatial elements. Especially, this study gives a fundamental ideas about private character of installations art in commercial spaces and expressional character of modern installations.

  • PDF