• Title/Summary/Keyword: Installation of ceiling and wall

Search Result 25, Processing Time 0.028 seconds

Evaluation of Floor Impact Sound Performance according to the installation of Ceiling and Wall (천장 및 벽구성 방법에 따른 바닥충격음 특성평가)

  • Kim, Kyoung-Woo;Choi, Hyun-Jung;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.261-264
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the installation of ceiling and wall. In this test, we measured the reduction of impact sound in the case of inserting absorption materials, increasing of the thickness of air layer and using anti-vibration rubber in ceiling, install of absorption materials in wall. The results of this study show that treatment of ceiling and wall have some reduction of the light weight impact sound and heavy weight impact sound.

  • PDF

The Study of the Most Suitable Location of Luminaire for Road Tunnel Lighting System (도로터널에서 최적의 조명기구 위치 연구)

  • 한완모;장우진;이인환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2004
  • As we know, topography of korea is composed of many mountains. Also, the volume of traffic is increasing more and more nowadays. So, many tunnels are being constructed to reduce cost of transport and time. Thus, tunnel illumination was considered as the most important thing to make safe traffic conditions. In the past, we installed luminaires on the wall in tunnel, but currently we are installing those on the ceiling. Wherever luminaires are installed on the ceiling, the electric designer may not have known the proper point to install luminaires. Therefore, we researched this project to resolve above problems with abundant experience and accurate data through simulation(Lightscape program). As a result of research, mounting luminaires on the ceiling are better than wall because uniformity is more regular and utilization factor is also higher and then brightness is adequate as well, whereby installation on the ceiling is economical. Therefore, it is suitable that luminaires are installed on the ceiling in tunnel than wall.

Triaxial Shake Table Test about Seismic Performance of Ceiling System with Gypsum Panels (석고 패널이 부착된 천장 시스템의 내진성능 평가를 위한 3축 진동실험)

  • Park, Hae-Yong;Jeon, Bub-Gyu;Kim, Jae-Bong;Gim, Min-Uk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.143-153
    • /
    • 2019
  • In this study, a full scale 3-axes shake table test for M-bar and T-bar type ceilings commonly used in the country was conducted. Through damage inspection during the test, seismic performance of ceilings according to variables, such as clearance between wall mold and ceiling as well as existence of facilities, was evaluated. A test frame consisted of square hollow section members was used for the shake table test. The experimental method was performed as a fragility test using required response spectrum described in ICC-ES AC156. In the case of architectural nonstructural component that contain ceilings, it mainly is evaluated the performance by post-test visual inspection. For the evaluation of seismic performance of ceilings, this study classified and defined damaged items for targeted ceiling system referring to illustrative damage according to nonstructural performance levels accordance with ASCE 41 and previous studies. And proposed illustrative damage items classification was utilized to compare the degree of the damage according to experimental variables. The experiment results confirmed that differences in boundary conditions due to the clearance at wall mold and the installation of facilities had a significant effect on the seismic performance of the ceiling.

The Characteristics of Dispersed Asbestos Fibers Produced From Building Materials (건축재료에서 발생되는 석면입자의 특성 연구)

  • 유성환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.191-199
    • /
    • 1993
  • This paper describes the results of a systematic study to determine the characteristics of particle generated from various types of asbestos containing material(ACM) and manmade fiber material(MMFM) during operations of cutting and grinding in laboratory and workplace. Tests were conducted with a specially designed glove box which allowed complete sampling of the generated asbestos fibers. Specificially, air measurements were made during ACM and MMFM installation in building. All personal air samples collected were identified by polarized light microscopy(PLM), X-ray diffraction(XRD) and scanning electron microscope with energy dispersive X-ray analysis(SEM/EDXA). Also, the samples were counted by phase contrast microscope(PCM) in order to compare the results with the permissible exposure standard for workplace. Results indicate that the characterisitcs of fibers found in the roofing sheet, the ceiling and the wall insulation boards were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of rock wool. The concentrations of airborne fibers from various building materials cut by a grinder for 5 minutes were in the ranges of 0.09 $\sim$ 1.71 fibers/cc(f/cc). The highest concentration(1.71f/cc) was found during grinding the wall insulation board which also contains rock wool. The airborne fiber concentrations generated by installing at workplace were ranged from 0.0009 to 0.029 f/cc. All asbestos fibers from the ceiling insulation board at workplace were less than 20$\mu$m in length and more than 20% of them had the average aspect ratio greater than 20. Therefore, for the purpose of decreasing asbestos and man-made fiber concentrations at the workplace, the ceiling and wall board should use strong binding material to increase the binding force with fiber. Also, the permissible exposure standard for workplace(2.0f/cc) in Korea should be constituted below the maximum avaiable concentration measured at glove box.

  • PDF

The Study of the Most Suitable Location of Luminaire for Road Tunnel Lighting System (도로터널에서 최적의 조명기구 위치 연구)

  • 한완모;장우진;이인환
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.25-29
    • /
    • 2003
  • As we know, topography of korea is composed of many mountains Also, the volume of traffic is increasing more and more nowadays. So, many tunnels are being constructed to reduce cost of transport and time. Thus, tunnel illumination was considered as the most important thing to make safe traffic conditions. In the past, we installed luminaires on the wall in tunnel, but currently we are installing those on the ceiling. Wherever luminaires are installed on the ceiling, the electric designer may not have known the proper point to install luminaires. Therefore, we researched this project to resolve above problems with abundant experience and accurate data through simulation(Lightscape program).

  • PDF

A Study on the comparison of Infill Technology between Korea long life Apartment Mock up House and Japan KSI experimental House (국내 장수명 공동주택 Mock-up House와 일본 KSI 실험주택 인필 요소기술 비교 연구)

  • Choi, Young Ho;Kim, Shin;Kim, Sung Wan
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.63-69
    • /
    • 2008
  • The thesis is a comparative analysis of Infill Technologies between Korea's long-life Mock-up House, a study driven by 'Durability and Flexibility of Long-life Housing Technology Development' of R&D, and Japan's KSI experimental house, the major example of Japan's long-llfe housing. In terms of the domestic Mock-up House, a system of building the floor first was applied. The floor material of each housing unit required a development of dry heating component that is partially substitutable in order to avoid conflict with the finishing. Also, a development of a floor system that can counteract against the construction inaccuracy was required. In the Case of an outer wall, need to make the wall with the chassis. In the case of ceiling, need to develop the double ceiling system which is good for sound insulation. Also, in comparison to KSI experimental house in Japan, it would require to develop a wiring system of the ceiling which can react to the movement of the wall. Especially, to assure the flexible nature of an internal wall, it would desperately require the research and development of the products related to components and flexible system of mechanical/electrical/communication parts as well as supporting institutionalized system for this development. Furthermore, for KSI experimental house in Japan, it would be necessary to formulate a construction manual as well as a systematic and practical planning guide to invent a new interface rule which will secure simplicity of assembling, dismantling, installation and replacement of architectural components for which research development is quite insignificant at the moment. This effort will have to continue to give a solid direction for better application of such reference manual during construction and development of long life span apartment by public sector as well as private corporations.

A Study on the transformation Pross of Vernacular Houses in Ulleung-Island -Focused on wall, roof, window and ceiling- (울릉도 민가의 변화과정에 관한 연구 -벽체, 지붕, 창호, 천장을 중심으로-)

  • Kim Chan-Yeong
    • Journal of the Korean housing association
    • /
    • v.15 no.5
    • /
    • pp.85-96
    • /
    • 2004
  • The purpose of this study was to (md out the characteristics of the residential house in Ulleung Island in terms of building materials, structure and construction method, structural design by actual field surveys. This study found several facts; First, the house was classified into the log house and mud-wall house according to building material for wall structure. The log house prevailed in the early days of the settlement in the island because of affulent timber materials available around. However, the mud wall house became a popular type in later days because of the depletion of timber materials. Second, the Udeki wall was an unique installation reflecting the severe climate conditions of Ulleung Island. However, many aspects of the Udeki wall was changed according to the change of living style and the introduction of modem heating systems in terms of its function, size, building material, layout position etc. Third, the roofing material also has been changed from materials available locally to slate materials transported from the mainland. Fourth, the bamboo slender-ribbed door as a single-swing door type was popular and later time the single-sliding door or three ribbed door was widely used in rooms installed later instead. Fifth, the roof was placed over the room, kitchen, and Chukdam (outer wall) and this was a resonable way to cope with heavy snowfalls in the winter season in Ulleung Island.

A Experimental Study on Artificial Illumination Control System Illuminated by Daylighting (자연채광을 이용한 인공조명의 제어방법에 관한 실험적 연구)

  • 차광석;김회서
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.21-28
    • /
    • 1994
  • It is very important and necessary to predict luminous enviroment in an interior space. This paper has described about energy saving and evaluated interior visual environment in a office building having on/off turning control lighting system utilizing daylight. In order to predict the interior varior illumination distribution, the scale model was made and examined under various conditions, such ad difference of window glass, and color pattern of wall, floor, and also ceiling lighting system type. This paper suggests that basic fundamental data of lighting design performance in the concept and schematic stages of design.

  • PDF

An Improvement of Welding Method for the Corrugated Stainless Steel Tubing(CSST) (가스용 금속 플렉시블 호스의 용접방법 개선에 관한 연구)

  • Kim, Wan-Jin;Yi, Yeong-Seop;Choi, Jin-Lim
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.79-83
    • /
    • 2008
  • The corrugated stainless steel tubing(CSST) for the fuel gas piping system can be installed easily and quickly. It is often constructed under the ceiling and the wall which has a good flexibility and installation in comparison with iron pipe. However, the quality of the CSST is determined to depend upon the welding skill of stainless steel tubing. In this study, it is tested by controlling jet point of Ar as inert and cooling gas, and also compared with the bead state of welding point and the performance. As a result, it has the best condition when the jet point of Ar is located behind $5{\sim}10mm$ of the welding point.

Actual Condition of Remodeling in Apartment Unit - Grasp of Remodeling elements by Specialists' In-depth Interviews - (아파트 단위주거의 리모델링 실태 - 실무자 심층면접에 의한 리모델링 요소 현황 파악 -)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Jeong, Youn-Hong
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.81-84
    • /
    • 2007
  • The purpose of this study was to grasp actual condition of remodeling elements by specialists' in-depth interviews. The interview has been conducted to interior designer who have a wide experience of apartment remodeling. In-depth interview is a kind of qualitative method in which attention to reply of responses with open-access between interviewer and respondents. According to the results, remodeling elements were generally the renovation of balcony into the livingroom or children room, removal a doorsill, installation of storage furniture, change of lighting fixtures in the all rooms and change equipments of bathroom. Finishing materials were usual used normal wallpaper and normal or low emitting adhesive on ceiling and wall, tempered-flooring on floor, and ceramic tiles on bottom and wall of bath and entrance.

  • PDF