• Title/Summary/Keyword: Installation method

Search Result 3,278, Processing Time 0.025 seconds

Lead-acid battery management system in UPS (UPS의 납축전지 관리 시스템)

  • 임영철;변성천;김의선;장영학
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.177-180
    • /
    • 1998
  • To manage lead-acid battery efficiently and to use it longer in UPS, the state of charge(SOC) indicator of the battery is needed. So a new approach to developing battery SOC indicator for UPS is discussed in this paper. This method to determining SOC by combining the available data of discharge characteristics of a battery with neural networks(NN) is presented. The 3-layered NN with back propagation algorithm has been used. Exprement results show that the proposed method is appropriate as SOC indicator of the battery.

  • PDF

Color reappearance investigation of monitor for reception such as TV broadcasting in digital age (디지털 시대의 TV방송등 수신용 모니터의 색 재현 고찰)

  • Kang, Tae-Keun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.570-574
    • /
    • 2004
  • Technical supply reason of digital base and important color reappearance of WEB base that is diffused rapidly on industry whole. Examined my outside factor investigation and revision method of inaccurate color reproduction and color reappearance valuation method influencing in color reappearance of monitor for last reception using in on-line shopping as well as end consumers in graphic age

  • PDF

Situation and Improvement Method of Railroad Platform Lighting (철도 승강장 조명의 현황과 개선책)

  • 김병봉;장우진;한성호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.3-8
    • /
    • 2003
  • Platforms of many railroad stations are crowded with passengers regardless of the time throughout day. But the intensity of illumination of the existing lightening systems are so low enough to make passengers feel inconvenience in using platforms. Consequently there exists high possibility of accidents in platforms of low illumination. Hence, for the safety and convenience of passengers, it is necessary to improve the luminous intensity of lightening system for platforms. This paper points out the problems of existing system and presents the method to improve it.

  • PDF

Genetic algorithm-based ultra-efficient MPP tracking in a solar power generation system (태양광 발전 시스템의 효율증대를 위한 Genetic Algorithm을 적용한 MPPT Control)

  • Choi, Dae-Seub
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.460-461
    • /
    • 2006
  • This paper a new method which applies a genetic algorithm for determining which sectionalizing switch to operate in order to solve the distribution system loss minimization re-configuration problem. In addition, the proposed method introduces a ultra efficient MPP tracking in a solar power generation system.

  • PDF

Enhancing Installation Security for Naval Combat Management System through Encryption and Validation Research

  • Byeong-Wan Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.1
    • /
    • pp.121-130
    • /
    • 2024
  • In this paper, we propose an installation approach for Naval Combat Management System(CMS) software that identifies potential data anomalies during installation. With the popularization of wireless communication methods, such as Low Earth Orbit(LEO) satellite communications, various utilization methods using wireless networks are being discussed in CMS. One of these methods includes the use of wireless network communications for installation, which is expected to enhance the real-time performance of the CMS. However, wireless networks are relatively more vulnerable to security threats compared to wired networks, necessitating additional security measures. This paper presents a method where files are transmitted to multiple nodes using encryption, and after the installation of the files, a validity check is performed to determine if there has been any tampering or alteration during transmission, ensuring proper installation. The feasibility of applying the proposed method to Naval Combat Systems is demonstrated by evaluating transmission performance, security, and stability, and based on these evaluations, results sufficient for application to CMS have been derived.

The Analysis on the Oil Deterioration of Pole-Transformer by Non-Destructive and UV/Visible Method (비파괴 및 비색법에 의한 주상변압기 절연유의 경년열화 분석)

  • 곽회로;남영우;윤영자;권혁일;이동준;송일근;권동진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.115-117
    • /
    • 1995
  • This paper describes the O.T aging analysis by non-destructive electrical and UV/visible method. Non-destructive diagnosis method is tan8 test. Also the new method of the aging analysis, UV/visible method was introduced in this paper and compared with the non-destructive electrical method. The UV/visible test could be useful method for the O.T aging electrical diagnosis such as non-destructive electrical method.

  • PDF

Basic study on correction method of measured earthing resistance by 4-potential method

  • Saki, Ueta;Takehiko, Takahashi
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.53-56
    • /
    • 2008
  • The full of potential method is generally used for measuring the earthing-resistance. This method needs two auxiliary electrodes and it is required that two auxiliary electrodes are placed at enough distances from the earthing electrode, e.g. building foundation. However, in urban area there is not enough space for taking measurement. So, it is very difficult to measure the earth resistance precisely. However, there is the 4- potential method when it stand on the theory of the full of potential method. It is the purpose of this paper to basic study on correction method of measured earthing resistance by 4-potential method.

  • PDF

Lightings Arrangement Method of the Small Gymnasiums (소형 옥내 운동장의 조명기구 배치방식)

  • Kim, Tae-Hoon;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.1-6
    • /
    • 2014
  • In KSC 3706, the gymnasiums are classified according to their size(small, medium, large) and there are two kinds of illumination arrangement method for them such as Side and Distributed. The characteristic of the distributed illumination arrangement method is excellent in uniformity and the characteristic of the side illumination arrangement method is excellent in glare. but illuminations were so diverse that features are not always applicable. So in this paper, in this paper, We analyzed characteristic of distributed illumination arrangement method and side illumination arrangement method using nine illumination.

A Time-Saving Method for Analyzing Permanent Magnet Motors

  • Won, Sung-Hong;Han, Ki-Soo;Kim, Tae-Heoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.11
    • /
    • pp.17-22
    • /
    • 2010
  • This paper presents a unique method for simulating permanent magnet motors without time-consuming numerical methods used in the conventional magnetic circuit method. The conventional method gives us average values like torque and power over specified periods of time, but it is usually very difficult and time-consuming to obtain instantaneous characteristics like cogging torques and torque ripples. The convolution operations method we present, however, considers relative angle variations of stator magnetic circuits and rotor magnetic circuits. As a result, it makes uses of instantaneous values possible. The authors compare the new method with the coventional method and verify that calculating cogging torque values and back-emf values is possible with the proposed new convolution method.

A Study on the Assessment of Safety Performance for Complex Installation System of Stationary Fuel Cell and Boiler (건물용 연료전지-보일러 복합설치 안전성능 평가에 관한 연구)

  • Kim, Min-Woo;Lee, Eun-Kyung;Oh, Gun-Woo;Lee, Jung-Woon;Lee, Seung-Kuk
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.77-86
    • /
    • 2018
  • Interest in renewable energy is increasing for eco-friendly use of energy, and fuel cells are being used in various ways such as houses and buildings as power generation methods that have low emissions such as $NO_X$ and $CO_2$. As the supply of fuel cells expands, more and more boilers are installed in the existing buildings, but safety management is not being performed properly. Therefore, in this study, a prior study was conducted on the status of fuel cell-boiler complex installation and related criteria, and the risk factors were analyzed according to the installation environment and structure. Based on these standards, the safety performance of the fuel cell-boiler combined installation is assessed by conducting a demonstration using the starting product of the simulated operation to derive the installation criteria (proposal) for the fuel cell-boiler combined installation. The installation criteria (proposal) include the construction and connection method of the piping according to the fuel cell-boiler complex installation.