• Title/Summary/Keyword: Installation method

Search Result 3,269, Processing Time 0.033 seconds

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Development of Fertilizer-Dissolving Apparatus Using Air Pressure for Nutrient Solution Preparation and Dissolving Characteristics (공기를 이용한 양액 제조용 비료용해 장치 개발 및 용해특성)

  • Kim, Sung Eun;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.3
    • /
    • pp.163-169
    • /
    • 2012
  • We have conducted three experiments to develop a fertilizer-dissolving apparatus used in fertigation or hydroponics cultivation in order to decrease the fertilizer dissolving time and labor input via automation. All of the experiments were conducted twice. In the first experiment, four selected treatments were tested to dissolve fertilizers rapidly. The first treatment was to dissolve fertilizer by spraying water with a submerged water pump, placed in the nutrient solution tank. The water was sprayed onto fertilizer, which is dissolved and filtered through the hemp cloth mounted on the upper part of the nutrient solution tank (Spray). The second treatment was to install a propeller on the bottom of the nutrient solution tank (Propeller). The third treatment was to produce a water stream with a submerged water pump, located at the bottom of the tank (Submerged). Finally, the fourth treatment was to produce an air stream through air pipes with an air compressor located at the bottom of the tank (Airflow). The Spray treatment was found to take the shortest time to dissolve fertilizer, yet it was inconvenient to implement and manage after installation. The Airflow treatment was thought to be the best method in terms of the time to dissolve, labor input, and automation. In the second experiment, Airflow treatment was investigated in more detail. In order to determine the optimal number of air pipe arms and their specification, different versions of 6- and 8-arm air pipe systems were evaluated. The apparatus with 6 arms (Arm-6) that was made of light density polyethylene was determined to be the best system, evaluated on its time to dissolve fertilizer, easiness to use regardless of the lid size of the tank, and easiness to produce and install. In the third experiment, the Submerged and Arm-6 treatments were compared for their dissolving time and economics. Arm-6 treatment decreased the dissolving time by 8 times and proved to be very economic. In addition, dissolving characteristics were investigated for $KNO_3$, $Ca(NO_3)_2{\cdot}4H_2O$, and Fe-EDTA.

A Study on the Safety of Evacuation according to Evacuation Delay Time and Fire Door Openness: Based on Residence Types (피난 지연시간의 적용과 방화문 개방 정도에 따른 피난 안전성 확보에 관한 고찰 : 주거형태를 중심으로)

  • Seo, Dong-Gil;Kim, Mi-Seon;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.156-165
    • /
    • 2020
  • In this paper, the application of evacuation delay time (Cognition time + initiation time) and examine the degree of opening of fire doors in households for evaluating evacuation safety and suggest a realistic alternative. In order to proceed with this study, first of all, the preliminary investigation on evacuation safety evacuation of residential-type buildings (Apartment, urban living houses, etc.) among the performance-oriented design targets of Gwangju Metropolitan City, which was implemented until June 2018. Then, for the two representative types that are commonly used among the previously surveyed buildings, evacuation delay time is applied to W1, W2, and respectively simulating the opening of the doors is applied to th full open, 1/4 open, the leakage gap and evacuation safety evaluation was performed. As a result of evaluating evacuation safety was found that it is difficult to secure evacuation safety regardless of evacuation delay time W1 and W2 when the fire door is fully open and 1/4 open, Only when the leakage gap is applied evacuation safety was ensured even if evacuation delay time W2 was applied. Therefore, when a residential building is subject to performance-oriented design, evaluating the application of W2 rather than W1 is considered for evacuation delay time to reflect concern about privacy infringement due to CCTV installation, etc. In order to secure the Smoke blocking performance of the fire door and to improve the performance-oriented design, I would like to propose to consider the method of applying a leak gap to the degree of opening of the fire door. Through this, it is expected that the performance-oriented design will be a step further by performing evacuation safety evaluation with more realistic data.

Assessment of the usefulness of the Machine Performance Check system that is an evaluation tools for the determination of daily beam output (일간 빔 출력 확인을 위한 평가도구인 Machine Performance Check의 유용성 평가)

  • Lee, Sang Hyeon;Ahn, Woo Sang;Lee, Woo Seok;Choi, Jin Hyeok;Kim, Seon Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose: Machine Performance Check (MPC) is a self-checking software based on the Electronic Portal Imaging Device (EPID) to measure daily beam outputs without external installation. The purpose of this study is to verify the usefulness of MPC by comparing and correlating daily beam output of QA Beamchecker PLUS. Materials and Methods: Linear accelerator (Truebeam 2.5) was used to measure 10 energies which are composed of photon beams(6, 10, 15 MV and 6, 10 MV-FFF) and electron beams(6, 9, 12, 16 and 20 MeV). A total of 80 cycles of data was obtained by measuring beam output measurement before treatment over five months period. The Pearson correlation coefficient was used to evaluate the consistency of the beam output between the MPC and the QA Beamchecker PLUS. In this study, if the Pearson correlation coefficient is; (1) 0.8 or higher, the correlation is very strong (2) between 0.6 and 0.79, the correlation is strong (3) between 0.4 and 0.59, the correlation is moderate (4) between 0.2 and 0.39, the correlation is weak (5) lower than 0.2, the correlation is very weak. Results: Output variations observed between MPC and QA Beamchecker PLUS were within 2 % for photons and electrons. The beam outputs variations of MPC were $0.29{\pm}0.26%$ and $0.30{\pm}0.26%$ for photon and electron beams, respectively. QA Beamchecker PLUS beam outputs were $0.31{\pm}0.24%$ and $0.33{\pm}0.24%$ for photon and electron beams, respectively. The Pearson correlation coefficient between MPC and QA Beamchecker PLUS indicated that photon beams were very strong at 15 MV, and strong at 6 MV, 10 MV, 6 MV-FFF and 10 MV-FFF. For electron beams, the Pearson correlation coefficient were strong at 16 MeV and 20 MeV, moderate at 9 MeV and 12 MeV, and very weak at 6 MeV. Conclusion: MPC showed significantly strong correlation with QA Beamchecker PLUS when testing with photon beams and high-energy electron beams in the evaluation of daily beam output, but the correlation when testing with low-energy electron beams (6 MeV) appeared to be low. However, MPC and QA Beamchecker PLUS are considered to be suitable for checking daily beam output, as they performed within 2 % of beam output consistency during the observation. MPC which can perform faster than the conventional daily beam output measurement tool, is considered to be an effective method for users.

  • PDF

Improvement Method of Hazardous Materials Facilities Installation License of Manufacturer (위험물시설의 설치허가제도의 개선방안)

  • 이종영;이수경;김태환
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.21-35
    • /
    • 2001
  • By rearing private experts to design hazardous facilities, Safety property is obstained. So it is necessary to limit within the designer of hazardous materials facilities who has some degree skill. After permission progress about the inspection of the design ascertain whether it is safety property Mayor/Do governor permits within the laws and their qualification. Accordingly, Korea Fire Equipment Inspection Corporation be come specialization about the design, inspection of construction completion. A inquire purpose of Fire Service Act be considered fitness. Subject by which the Korea Fire Equipment Inspection Corporation is entrusted, subject by which the a non-probit corporation in The Civil Law be possible to entrusted in separate. In this case, because of the level of one's technique and facilities are important, to limit as a nonprobit corporation in The Civil Law give rise to trouble. Consequently; established a business corporation, which the level of one's technique and facilities, in accordance with The Commercial Law can assign inspection of construction completion. The contents of the Fire Services Act is caused by the historic growth of hazardous facilities's safety management. Because we decide on a course about completed inspection of hazardous substance, it is needed that adjust the task performed by a corporation of the exert skill and the duty performed by the task that a authorized corporation on the civil law or the commercial law To adjust the duty, the Fire Service Act, that is suitable to the purpose and principle, should constitute a measure of the duty. With the object of insure the safety of the hazardous substance, when the fire survice act establish a corporation of the expert skill. There is the will of lawmakers that need organization to have the power of the professional technology. The state excise the will that insure the safety of hazardous materials facilities on the basis of the professional technology and facilities, and construct to establish a corporation of the expert skill. Therefore as concentrate on the technology to need to insure the safety of the facilities of hazardous substance to be suitable on the purpose of laws and take responsibility and reports to a corporation of the expert skill. The task to be given to the state will be done.

  • PDF

Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam (PET/CT 검사 환자의 피폭선량 경감을 위한 연구)

  • Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.10-16
    • /
    • 2009
  • Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

  • PDF

Reviews of Radiation Protection and Shielding for Computed Tomography in Foreign Countries (외국의 컴퓨터 단층촬영 장치의 방어시설 문헌 조사)

  • Jahng, Geon-Ho;Yang, Dal-Mo;Sung, Dong-Wook;Lee, Kwang-Yong;Kim, Hyeog-Ju
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.276-284
    • /
    • 2008
  • A computed tomography (CT) is a powerful system for the effectively fast and accurate diagnosis. The CT system, therefore, has used substantially and developed for improving the performance over the past decade, resulting in growing concerns over the radiation dose from the CT. Advanced CT techniques, such as a multidetector row CT scanner and dual energy or dual source CT, have led to new clinical applications that could result in further increases of radiation does for both patients and workers. The objective of this study was to review the international guidelines of the shielding requirements for a CT facility required for a new installation or when modifying an existing one. We used Google Search Engine to search the following keywords: computed tomography, CT regulation or shield or protection, dual energy or dual source CT, multidetector CT, CT radiation protection, and regulatory or legislation or regulation CT. In addition, we searched some special websites, that were provided for sources of radiation protection, shielding, and regulation, RSNA, AAPM, FDA, NIH, RCR, ICRP, IRPA, ICRP, IAEA, WHO (See in Table 1 for full explanations of the abbreviations). We finally summarized results of the investigated materials for each country. The shielding requirement of the CT room design was very well documented in the countries of Canada, United States of America, and United Kingdom. The wall thickness of the CT room could be obtained by the iso-exposure contour or the point source method. Most of documents provided by international organizations were explained in importance of radiation reduction in patients and workers. However, there were no directly-related documents of shielding and patient exposure dose for the dual energy CT system. Based international guidelines, the guideline of the CT room shielding and radiation reduction in patients and workers should be specified for all kinds of CT systems, included in the dual energy CT. We proposed some possible strategies in this paper.

  • PDF

Development of Parking Space Forecast Model for Large Traffic-inducing Facilities Considering Surrounding Circumstance (주변 환경을 고려한 대규모 교통유발시설 주차면산정 모형개발에 관한 연구 - 판매시설을 중심으로 -)

  • Park, Je jin;Oh, Seok Jin;Kim, Sung Hun;Ha, Tae Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.593-601
    • /
    • 2017
  • With the rapid industrial development and national economic advance since 1970, the national income of Korea has sharply increased. As a result, issues regarding city expansion, urban concentration, increase in the number of registered motor vehicles, and increase in traffic have caused transportation issues such as traffic congestion and problems with parking. Especially, enforcement ordinances and rules have been established on installation and management of parking lots to solve problems with parking which are raised as social problems such as conflict with neighbors but the flexible calculation of legal parking space has the limitations because of the diversity and complex functionality of purposes of facilities. Accordingly, this study attempted to supplement such demerit of the parking space demand forecast method based on the legally required number of parking spaces and average unit requirement in the parking space supply. This study estimated the required number of parking spaces by analyzing existing literature, collecting field research data, and analyzing the factors that have an impact on the parking demand. Also, it compared the required number of parking spaces based on the average unit requirement as well as the required number of parking spaces by the forecast model based on the cumulative number of motor vehicles parked. The result was that the required number of parking space based on average unit requirement was less than the cumulative number of motor vehicles parked by 9.99%. Meanwhile, the required number of parking spaces by the forecast model was more than the cumulative number of motor vehicles parked by 4.37%. Therefore, it is believed that the parking space forecast model is more efficient than the others in estimating there quired parking space. The parking space forecast model of this study consider different environmental factors to enable practical parking demand forecast considering the local characteristics and thus supply the parking space in an efficient way.

Vegetation Structure Characteristics and Management Plan of Mulgeun Fish Shelter Forest in the Southern Coast (남해안 물건리 방조어부림의 식생구조 특성 및 관리방안)

  • Lee, Soo-Dong;Kim, Mi-Jeong;Kang, Hyun-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.1
    • /
    • pp.118-128
    • /
    • 2016
  • The purpose of this study is to present efficient methods of preserving and managing the fish shelter forest in Mulgun-ri on the southern coast of Korea on the basis of its humanistic, sociological and ecological characteristics. The study object is Korean natural monument No. 150, which is presumed to have been forested by descendants of Jeonju Lee Family who settled there, and village rituals are held every October to pray for the peace of the village. The forest is managed by Namhae-gun as a historical and cultural resource as well as its disaster-preventing, economic, and environmental and ecological functions. The linear form of the area is $23,962.6m^2$ and farmland(48.5%) and urbanization area(38.2%) are extensively located in its periphery area. Actual vegetation was sub-classified into three types of land according to use pressure and whether or not damage was done: land where its stratification was formed; land where it was restored, and the land where it was damaged. Plant communities were sub-classified into Aphananthe aspera community(I) and Zelkova serrata community(II) which had a low use pressure; Z. serrata-Chionanthus retusa-A. aspera community(III) and A. aspera-Z. serrata community(IV) which had a high use pressure; and Celtis sinensis-A. aspera community(V) whose underlayer was damaged by use. Fragmentation of the forest is under way and its inside vegetation growth is hampered due to the installation of traffic and resting facilities such as the through roads costal roads, wooden-deck walkways, parking lots, washstands, etc. As a restoration management plan for this, the following were required: an establishment of preferred restoration area; a selection of restoration vegetation species; and an appropriate restoration method. The damaged area($7,868.2m^2$) will have to be set up as the preferred restoration area; seedlings of restored vegetation species should be raised with dominant species within the forest(i.e., Z. serrata, A. aspera, C. sinensis, and C. retusa) as their 'mother trees' for the benefit of for the next-generation forest; and sub-tree and shrub layer should be complementarily planted with 5 and 115 trees(unit $100m^2$) respectively to facilitate the formation of a multi-layered vegetation structure. In addition, resting facilities scattered inside the forest should be demolished; and indiscriminate use of them should be controlled; management and monitoring should be carried out so that the area can be preserved and restored as a deciduous broad-leaved forest.

Analysis of Distribution Characteristics of Flowrate and Water Quality in Tributary at Chungcheongnam-do (충청남도 지류하천의 유량 및 수질 분포특성 분석)

  • Park, Sang-Hyun;Moon, Eun-Ho;Choi, Jeong-Ho;Cho, Byung-Wook;Kim, Hong-Su;Jeong, Woo-Hyeok;Yi, Sang-Jin;Kim, Young-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.739-747
    • /
    • 2011
  • The major 81 tributaries in Chungcheongnam-do were monitored for flowrate and water quality in order to understand the characteristics of the watershed and to select the tributary catchment for improving water quality. The value of flowrate in the tributaries at Nonsancheon catchment at the Geum-River watershed and Gokgyocheon, Muhancheon, Sapgyocheon at the Sapgyo-Reservoir watershed, which is located in the southern and northern area in Chungcheongnam-do, was relatively greater than the other watersheds. The concentration of water pollutants regardless of water quality parameters in Nonsancheon catchment at the Geum-River watershed, Gokgyocheon catchment at the Sapgyo-Reservoir watershed and the Anseongcheon watershed, which have a dense source of pollution, were higher than the other watersheds. However, 64 percent of the tributaries at the Geum-River watershed, 45 percent of tributaries at the Sapgyo-Reservoir watershed, 26 percent of tributaries at the Geum-River watershed all satisfied the Class II regulations in the Framework Act on Environment Policy, but all of the tributaries located in the Anseongcheon watershed exceeded the Class II regulations. Therefore, the policy for improving the water quality of the tributary in Chungcheongnam-do should be established in the following order: Anseongcheon, Seohae, Sapgyo-Reservoir watersheds. Consequently, the tributary catchment for improving water quality, which has a large flowrate and a high concentration of water pollutants, was selected at Ganggyeongcheon, Geumcheon, Nonsancheon, Seokseongcheon, Seungcheoncheon, Jeongancheon, Jeungsancheon (so far Geum-River watershed), Gokgyocheon, Namwoncheon, Maegokcheon, Muhancheon, Sapgyocheon Oncheoncheon, Cheonancheon (so far Sapgyo-Reservoir watershed), Gwangcheoncheon, Dangjincheon, Daecheoncheon, Dodangcheon, Waryongcheon, Cheongjicheon, Pangyocheon, Heungincheon (so far Seohae watershed), Dunpocheon, Seonghwancheon, Ipjangcheon (so far Anseongcheon watershed). The plans as installation of environmental facilities to reduce the source of pollution for improving the water quality of these tributary catchments should be urgently established and implemented.