• Title/Summary/Keyword: Installation guide

Search Result 147, Processing Time 0.036 seconds

Implant Fixture Installation in the Posterior Maxilla Using a Tooth-supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터 보조 기반 치아 지지 서지컬 템프레이트를 이용한 상악구치부 임플란트 식립)

  • Kim, Soung Min;Kim, Myung Joo;Lee, Jee Ho;Myoung, Hoon;Lee, Jong Ho;Kim, Myung Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.6
    • /
    • pp.381-389
    • /
    • 2013
  • Two patients with partial edentulous maxilla were scheduled to undergo installation of implant fixtures using a tooth-supported surgical template based on computer assisted treatment planning. After 3-dimensional (3D) computed tomographic scanning was transferred to the OnDemand3D (Cybermed Co., Seoul, Korea) software program for virtual planning, fixtures of MK III Groovy RP implant of the Br${\aa}$nemark System (Nobel Biocare AB Co., G$\ddot{o}$teborg, Sweden) was installed using the In2Guide (CyberMed Co., Seoul, Korea) tooth-supported surgical template with a Quick Guide Kit (Osstem Implant Co., Seoul, Korea) system in the posterior maxilla of each patient. Sinus floor elevation with a xenogenic bone graft procedure was also performed simultaneously in one patient. Fixture installations were completed successfully without complications, such as sinus mucosa perforation, bony bleedings, fenestrations, or others. During the last two-year follow-up period after prosthetics delivery, each implant was found to be fine with no other minor complications. The entire procedures are reported and the literatures on use of tooth-supported surgical template was reviewed.

Stability Evaluation during Transportation of Offshore Wind Turbine by Barge (바지선을 이용한 해상풍력발전기 운반에 따른 안정성 평가)

  • Seok, Jun;Back, Young-Soo;Park, Jong-Chun;Kim, Sung-Yong;Cha, Tae-Hyung;Yang, Young-Jun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.3
    • /
    • pp.196-203
    • /
    • 2017
  • In general, the installation of offshore wind turbine have been carried out by a jack-up barge or wind turbine installation vessel. In case of using jack-up barge, an additional barge is required to transport offshore wind turbines. During the transportation, barge is affected by environmental conditions such as wave, wind etc. So, it is important to secure the static and dynamic stability of the barge. In this study, fundamental research was performed to evaluate the stability of barge due to use the guide frame. The analysis for static stability of barge was performed under the two loading conditions with or without wave and those results were evaluated according to the Ministry of Oceans and Fisheries rules. Also motion analysis was performed under the ITTC wave spectrum using buoy data and evaluated based on NORDFORSK guideline by using commercial software Maxsurf Motions.

A Study on the Hydraulic Experiments of Modi Khola Hydroelectric in Nepal (네팔 Modi Khola 수력발전소 수리모형실험 연구)

  • 선우중호;박창근
    • Water for future
    • /
    • v.28 no.1
    • /
    • pp.107-120
    • /
    • 1995
  • This study is concerned with the hydraulic experiments of Modi Khola Hydroelectric in Nepal. The experimental domain consists of the intake structure and the settling basin. The intake structure was made by the undistorted model with the scale of 1:20, the settling basin by the distorted model with the scale of 1:10(vertical) and 1:15(horizontal). Based on the movable bed model theory, the 'Anthracite'($\rho_s$ =1.48) is chosen as a model material. According to the model tests, the installation of the guide wall with proper height and the proper control of the flushing gate are required for the effective flushing in the intake structure. In the settling basin a more proper design of the inlet in order to constrain the turbulence flow is required for an efficient sedimentation and the installation of another flushing pipe near the maximum sedimental area is required. Since the trap efficiency is measured about 95%, it is concluded that the design of the settling basin is proper.

  • PDF

The Method of Force of Fire in High-Rise Building by Guide to the Fire Safety Concepts Tree: Focusing on Manually Fire Suppression Strategy (화재안전트리 이론에 따른 초고층건축물의 소방력 공급방안: 수동화재진압 전략을 중심으로)

  • Oh, Seong-Ju;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.79-88
    • /
    • 2020
  • This study analyzes the issue of the supply of force of fire in the high-rise buildings, and proposes an efficient method to do so. The results are as follows. First, in terms of Detect fire, it is necessary to shorten force of fire supply time by diversifying fire alarms such as alarms, vibrations, and voices from outside, clarification of fire occurrence points, and marking of fire. Second, with regard to communication signals, strengthening the installation target of wireless communication auxiliary facilities, supplementing the installation of repeaters, and constructing a multicommunications network were proposed. Third, in terms of Decide action, it is necessary to supply firefighter and firefighting equipment with the method of crossing of a river in adjacent buildings. Fourth, in terms of Respond to site, helicopters and emergency elevators are used to assist in the supply of firefighting equipment using drones. Easy-to-break glass windows and identification marks are required in every floor. Finally, in terms of applying fire suppressants, water can be supplied by means of a helicopter adjacent to the structure.

Data Acquisition System Design of I&C System in Nuclear Power Plant (원자력 발전소 계측제어시스템의 정보취득장치 설계)

  • 조정환;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.102-108
    • /
    • 2003
  • This paper presents a new Data acquisition system that can improve a accuracy and response characteristics by designing a SDAS(Signal Datat Acquisition System). I&C(Instrumentation and Control) system, which it applied for Nuclear Power Plant, affects for safety either directly or indirectly. It should be assessed by the equipment qualification procedure to confirm the functionality during design life before it apply on the nuclear power plant depending on safety classification. This paper proposes data acquisition system that required as an essential measurement equipment in the method and procedure of equipment qualification following of standards and codes of IEEE and Nuclear Regulatory Guide. It provides comparable and experimental studies have been carried out. The presented results from the above investigation show considerably improved accuracy performance in the data acquisition system. This circuit will be able to be used in high performance I&C system.

Development of Electronic Limit Switch for the Drive Unit of Incore Detector System Application (노내 핵계측 계통 구동기기의 전자식 한계스위치 개발)

  • 박종범;양승권;이상효
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.1-7
    • /
    • 2000
  • In this paper, we study a cause of malfunction of switch to control drive motor in DFMS(Digital Flux Mapping System) which can measure incore neutron flux of the nuclear plant, and develope a method to solve this problem. DFMS has the type of generating contact signal by mechanical switch lever, which is operated whenever thimble detector inserted or withdrawed through thimble Guide Tube. However the characteristics of the lever tend to be changed by mechanical degrade or bad environment and the lever finally generates errotic contact signal. Therefore we installed electric coil ass'yin the outside of Guide Tube instead of mechanical switch assy's. In addition we applied resonance effect to control circuit and installed condenser in the input of power supply to protect noise and interference. After completion of this improvement, we tested this improved device repetitively under the various conditions. In conclusion, we identified the generation of the desired contact signal and the prevention of detector failure through plant surveillance test during normal plant operation.

  • PDF

Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report (무치악 환자에서 CAD/CAM을 이용한 임플란트 식립($NobelGuide^{TM}$) 및 즉시하중 증례)

  • Ko, Kyoung-Ho;Lim, Kwang-Gil;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.233-245
    • /
    • 2011
  • With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.

A Study on the Discharge Guide Technology by infrared Laser Applied to Discharge Processing Devices (적외선 레이저에 의한 방전 유도 기술의 방전 가공 장치에의 적용 연구)

  • 조정수;이동훈;남경훈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • In recent years, concern has been raised about the technique of controlling electrical breakdown by using laser in many fields. Especially, laser has attracted much attention in the Electro-Discharge Machining(EDM) because of its many rrents. 1berefore, this research has been perfonred to obtain fundarrental data for the discharge guide technology by a pulsed Nd:YAG laser which can be awJied to discharge processing machining. 1be experilnnts of laser-guided de discharge have been carried out at low air pressure ranging from 0.2 to 20 torr. The minimum laser-guided de discharge voltage $V_{G.min}$ at the given pressures P and distances d between an anode and a cathode was rreasured It is found that $V_{G.min}$ is much lower than the natural discharge voltage $V_{ND}$, and the values of VGrrin and $V_{ND}$ as a function of P.d has a similar tendency. The laser output energy $E_{out}$ decreases with input pulse duration $t_p$ increasing, and the rrore the value of $t_p$ increases, the higher that of V$V_{G.min}$ is obtained because the number of photons N decreases with $t_p$ increasing. In addition, the laser-guided de discharge range and the discharge guide characteristics as laser outpIt $E_{out}$ was investigated.igated.

  • PDF

Improvement of Field Installation Method for Asphalt Concrete Pavement Strain Gauge (아스팔트 콘크리트 포장 변형률계 매설 방법 개선에 관한 연구)

  • Lee, Jae-Hoon;Kim, Ji-Won;Kim, Do-Hyung;Lee, Kwang-Ho
    • International Journal of Highway Engineering
    • /
    • v.5 no.3 s.17
    • /
    • pp.31-42
    • /
    • 2003
  • The KHC Test Road project was initiated on 1991 to develop Korean Pavement Design Guide. It was constructed along the Joongbu Inland Expressway line between Yeoju and Gamgok. It is two-lane wide expressway containing fifteen asphalt and twenty-five Portland cement concrete test pavement sections. Various sensors were installed in the Test Road to evaluate the behavior of test pavement sections under the influence of traffic load and environmental change. The most important issues in the sensor installation are the accurate location and long-term survivability. They are directly influenced by the sensor installation methodology. The methodology for asphalt strain gages is mainly discussed in this paper because it is the second important sensors in the KHC Test Road project. In order to find the best methodology, we evaluated existing methodology from prior experience and several conducted test installations. We have tried mound, block out, and trench cuts since 2000. Among three methods, block out was the most effective one in terms of accurate location, long-term survivability, and material homogeneity. However, this method cannot be applied to the wearing coarse so that the mound method was used as an alternative. The block out method was applied to base and intermediate layers while the mound method was used to the wearing coarse. Three hundred seventy-four asphalt strain gauges were installed on asphalt pavement sections from September 3rd to November 18th in 2002. According to the sensor measurement evaluation, 6.3% of sensor demonstrated over ranged readings for mound method installation and 2.5% did for block out method installation. We lost only two sensors during the installation. It is 99.5% survival and it is excellent survival rate according to other experience.

  • PDF

Numerical Study for Flow Uniformity in Selective Catalytic Reduction(SCR) Process (SCR 공정에서 반응기 내부의 유동 균일화를 위한 수치적 연구)

  • Jung, Yu-Jin;Hong, Sung-Gil;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4666-4672
    • /
    • 2011
  • Performance of NOx removal in SCR(Selective Catalytic Reduction) process depends on such various factors as catalyst factors (catalyst composition, catalyst form, space velocity, etc.), temperature of exhaust gas, and velocity distribution of exhaust gas. Especially the flow uniformity of gas stream flowing into the catalyst layer is believed to be the most important factor to influence the performance. In this research, the flow characteristics of a SCR process at design stage was simulated, using 3-dimensional numerical analysis method, to confirm the uniformity of the gas stream. In addition, the effects of guide vanes, baffles, and perforated plates on the flow uniformity for the inside and catalyst layer of the reactor were studied in order to optimize the flow uniformity inside the SCR reactor. It was found that the installation of a guide vane at the inlet duct L-tube part and the installation of a baffle at the upper part is very effective in avoiding chaneling inside the reactor. It was also found that additional installation of a perforated plate at the lower part of the potential catalyst layer buffers once more the flow for very uniform distribution of the gas stream.