• 제목/요약/키워드: Installation criteria

검색결과 298건 처리시간 0.026초

장애인 이용을 고려한 사회복지관 편의시설 평가 및 분석에 관한 연구 (A Study on the Evaluation and Analysis of Convenient Facilities in Social Welfare Hall through Consideration of the Disabled Person Use)

  • 정례화;이완건
    • 한국실내디자인학회논문집
    • /
    • 제18권3호
    • /
    • pp.114-121
    • /
    • 2009
  • The number of the disabled is increasing every year. Growing interest in social welfare, but still the disabled person in places is restricted on the activities are due to obstacles. This study proposes an improvement direction through an research and analysis of installation status of convenient facilities in social welfare halls was planned after that the law of increase of convenience for the disabled person is enforced in 1998. This study analyzed nine social welfare halls of seoul including Yongsan-gu(GW), Guro-gu(GD, HW), Yeongdeungpo-gu(SG), Seodaemun-gu(SD), Dobong-gu(DB), Nowon-gu(NS), Seongbuk-gu(WG) and Dongdaemun-gu(JG). The evaluation criteria for the installation of convenient facilities for the disabled person in each social welfare hall based on the law of increase of convenience for the disabled person, and referred to other data. Also, review the criteria for the installation of convenient facilities, and grasp the present situation through the survey of convenient facilities in social welfare halls, and provides the installation standards of convenient facilities. The result are as followings. There were many problems to be improved in approach of the intermediate space, parking lot, entrance of the inside space and corridor that must be installed for the convenience of the disabled. In the intermediate space, the slope of the ramp, curb, induction handle etc. for a safety must be installed. Parking spaces for the disabled must be located closest to the main entrance, an induction marker or the handle, and the attachment of a directional sign etc. must be improved. In the inside space, it is convenient for the disabled person use to install an automatic door and swing door simultaneously at the main entrance. And, the height of the door handle, an induction block, a braille display panels of the appropriate height in the entrance, a braille display in start and end of the stairs handle, the handle of the side wall, the stairs to prevent slippage etc. must be improved in the corridors. The case of the sanitation which is a recommendation item is equipped formally with disabled toilets are difficult to use. Information and other convenience facilities for the disabled person in all the social welfare halls were not considered.

시각장애인 점자블록 설치기준 개선방안 연구 (A Study on Improvement of Installation Standards for Tactile Walking Surface Indicators)

  • 강병근;신동홍;박광재;김상운
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권1호
    • /
    • pp.57-66
    • /
    • 2015
  • Purpose : The guidelines of establishing convenience facilities for the handicapped have not consistently been provided to the identical criteria in walking facilities. Thus, transportation poor had difficulties in walking environment. Method : This study aims to suggest the practical direction of guidelines of establishing tactile walking surface indicators. To do this, this study examines the problems of the current guidelines for establishing facilities, and then analyzes international criteria, with comparing criteria used in German. Therefore, findings from those analyses can provide the secure and convenient environment for walking to transportation users, in particular blind and vision-impaired people, the handicapped, the child, and the elderly and the weak. Results : For the improvement of tactile walking surface indicators, the clear criteria of establishing tactile walking surface indicators is proposed, considering the characteristics of walking environment. Then, the sample items corresponding to the various situations need to be exemplified. To provide more secure environment walking for transportation poor, the establishing criteria partially adopted ideas from Universal Design also need to be developed. Implication : The proposed detail drawing of tactile walking surface indicators need to be tested by transportation users due to high safety in walking circumstance, and also the guidelines of continuously maintaining tactile walking surface indicators also needs to be studied.

LED집어등 설치에 따른 연안 채낚기 어선의 복원성능 (Stability of fishing vessel according to the LED luring lamp installation)

  • 정성재;안희춘
    • 수산해양기술연구
    • /
    • 제50권4호
    • /
    • pp.623-632
    • /
    • 2014
  • In this study, the stability of fishing vessels get some change in accordance with the installation of LED luring lamp in comparison with metal halide luring lamp were investigated. Inclining test for 9.77 ton class of squid jigging and hair-tail angling vessel was performed in order to make a stability evaluation. A performance analysis of the target vessels to the stability on the basis of KST-SHIP program was evaluated. The results were as follows in this study. The stability of the fishing vessel by a metal halide such as LED and the like according to the result obtained by the inclining test is a slightly present difference, and the stability is not affected. The fishing vessel with LED lamp installed satisfies all the stability criteria specified in law and IMO rule. Compared to the metal halide LED lamp the increase of the height of the center of gravity and the initial transverse metacenter was caused. Due to the LED installation, the somewhat wider wind area of the waterline, which appears as a result, does not lead to an actual increase in rolling period. But then it is necessary to be designed on that the LED lamp shape reduces wind pressure area. Because of LED lamp installation, the GM value of vessels is increasing faster rolling cycle so causes a decrease in the sense that the crew is aboard.

관로 이격거리에 따른 지중매설관의 거동특성 비교 (Comparison of Behaviors for Underground Flexible Pipes with Installation Gap)

  • 이대수;상현규;김경열;홍성연
    • 한국지반공학회논문집
    • /
    • 제19권5호
    • /
    • pp.79-87
    • /
    • 2003
  • 현행 지중전력선관로 건설시에 사용되는 표준공법은 관과 관사이의 거리를 l0cm 이격시켜 관로를 매설함에 따라 공정이 복잡하고, 경제적이지 못해 이에 대한 개선공법으로 관사이의 좌우이격거리를 없앤 접촉관 공법을 제안하였으며, 이 두 공법의 거동특성과 안정성을 비교$.$평가하고 지중매설관의 변형에 영향을 미치는 주요인자를 분석하기 위해 실규모 현장 실증실험을 수행하였다. 실험에 적용된 매설형태는 A-1급 도로포장아래 매설깊이 80cm, 100cm, 120cm 지점에 PE파형관이 각 공법형태에 맞게 매설되고, 외부하중으로 DB-24차량의 후륜하중 9.6ton이 매설관 상단 중앙에 정차했을 때 관이 받는 작용압력-변형률 특성을 분석하였다. 실험 결과, 지중매설관의 변형은 주로 시공과정중에 발생하는 것으로 나타났고, 특히, 모래되메움 공정 및 쇄석 포설 완료후에 변형이 가장 크게 발생하는 것으로 계측되었다. 그리고, 접촉관과 이격관 공법의 변형을 비교해 보면, 이격된 부분에 채워진 되메움재의 수동토압에 의한 저항압에 의존한 이격관 공법이 관과 관이 직접 접촉하여 관의 강성이 저항압으로 작용하는 접촉관 공법에 비해 변형이 작게 발생하는 것으로 분석되었다. 더불어 KS-C8455의 허용변형률 3.5%에 매설깊이 80cm, 100cm, 120cm에 묻힌 매설관이 공법 및 다짐방법에 관계없이 만족하는 변형률값을 보이고 있어 안전성을 확보하는 것으로 분석되었다.

항타 말뚝에서 항타관리시스템(Pile Installation Recorder-Driven Pile)의 적용성에 관한 연구 (Study on Application of PIR-D(Pile Installation Recorder-Driven Pile) in Driven Pile)

  • 박봉근;박민철;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.28-35
    • /
    • 2004
  • Driven pile has the excellent bearing characteristics and good economics, so it is known as the comparative piling method. To use the advantages of driven pile fully, it is necessary to perform the proper construction management. Engineers must drive pile to the proper bearing layer with proper blow energy and measure the blow count and penetration per certain depth to analyze the bearing capacity and driveability. In conventional method, these parameters have been measured manually so it was difficult to get good accuracy. After PIR-D(Pile Installation Recorder-Driven Pile) was attached to the driving equipment, the hammer efficiency, blow count and penetration in blow/10cm were measured automatically. In this paper, to givethe rational judgement criteria of bearing layer, driveability, blow/10cm according to pile depth during pile driving, the some relationship between the driving resistance and ground layer distribution was analyzed. The ground investigation during piles (PHC ${\Phi}450,\;{\Phi}400\;&\;Steel\;Pile\;{\Phi}609{\ast}16t$) installation in the marine clay layer in Incheon, the sandy soil layer in Yongin and the tuff layer in Pusan was done. And measuring hammer efficiency not doing recently, we could compare hammer efficiency(Eh) by PIR-D and energy transfer ratio(ETR) by Pile Dynamic Analyzer(PDA).

  • PDF

건물적용 태양광발전시스템의 국내 지역에 따른 설치각도별 연간 전력생산량 예측에 관한 연구 (Annual energy yield prediction of building added PV system depending on the installation angle and the location in Korea)

  • 김동수;신우철;윤종호
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.67-74
    • /
    • 2014
  • There have distinctly been no the installation criteria and maintenance management of BIPV systems, although the BIPV market is consistently going on increasing. In addition, consideration of the BIPV generation quantity which has been installed at several diverse places is currently almost behind within region in Korea. Therefore, the main aim of this study is to evaluate the BIPV generation and to be base data of reducing rate depending on regional installation angles using PVpro which was verified by measured data. Various conditions were an angle of inclination and azimuth under six major cities: Seoul, Daejeon, Daegu, Busan, Gwangju, Jeju-si for the BIPV system generation analysis. As the results, Seoul showed the lowest BIPV generation: 1,054kWh/kWp.year, and Jeju-si have 5percent more generation: 1,108.0kWh/kWp.year than Seoul on horizontal plane. Gwangju and Daejeon turned out to have similar generation of result, and Busan showed the highest generation: 1,193.5kWh/kWp.year, which was increased by over 13percent from Seoul on horizontal plane. Another result, decreasing rate of BIPV generation depending on regional included angle indicate that the best position was located on azimuth: $0^{\circ}$(The south side) following the horizontal position(an angle of inclination: $30^{\circ}$). And the direction on a south vertical position(azimuth: $0^{\circ}$, an angle of inclination: $90^{\circ}$) then turned out reducing rate about 40percent compared with the best one. Therefore, these results would be used to identify the installation angle of the BIPV module as an appropriate position.

도시부도로 VMS 이용자 효용의 평가기준에 관한 연구 (A Study on Evaluation Criteria of VMS User's Utility in Urban Roads)

  • 임준범;신소영;김태희;박범진
    • 한국ITS학회 논문지
    • /
    • 제10권3호
    • /
    • pp.36-46
    • /
    • 2011
  • 현재 각 지자체에서 교통정보센터를 운영하는 곳이 늘어나고 있고, 운전자들은 도시내도로에 설치된 VMS로 교통정보를 제공받아 활용하고 있다. 그러나 고속도로 및 도시고속도로와는 또다른 특성을 가진 도시부도로의 VMS에 대하여 이용자들이 갖는 효용을 평가한 사례는 없다. VMS는 예산을 들여 설치한 교통정보제공 매체인만큼 이용자들의 효용에 대하여 평가하고 관리할 필요가 있다. 본 논문은 도시부도로 VMS를 이용하는 운전자들의 효용이 대안경로 정보제공 유무가 가장 큰 영향이 있다고 판단하여 그 평가기준을 정립하였다. 대안경로가 있고, 정보도 주면 4점, 대안경로가 있고, 정보를 일부만 주면 3점, 대안경로가 있는데 정보를 안주면 2점, 대안경로가 없으면 1점으로 평가한다. 또한 최대한 많은 운전자들이 VMS를 봐야 그 VMS의 가치가 높아진다. 그러므로 VMS설치 위치는 같은 조건이라면 교통량이 많은 도로구간이어야 하므로, 이에 대한 평가기준을 정립하였다. 교통량에 따른 설치위치 기준은 시의 경계부(시계)와 도심부로 나누어 정립하였다. 본 연구결과는 현재 도시부도로의 설치되어 있는 VMS들의 이용자 효용을 높이는 방법 중 기초자료로 활용할 수 있다.

교차로에 인접한 부 도로의 적정 이격거리 산정 (Determination of the Required Minimum Spacing Between Signalized Intersection and Minor Road)

  • 권성대;김윤미;강남원;하태준
    • 대한토목학회논문집
    • /
    • 제34권2호
    • /
    • pp.573-582
    • /
    • 2014
  • 교차로에 인접한 부 도로에 대한 설치기준이 명확하지 않아 설치 및 운영에 많은 문제점을 야기시키고 있으며, 이로 인하여 교통소통과 교통안전에 문제가 발생하고 있다. 현재까지 교차로 진출입과 관련하여 운영적인 측면에서는 많은 연구가 시도되었지만, 교차로에 인접한 부 도로에 대한 연구는 대단히 미흡하고 이에 따른 합리적인 설계가 이루어지지 못하는 실정이다. 이에 본 연구에서는 교차로에 인접한 부 도로에서 진출하는 차량에 대한 행태를 조사하고, 교통소통과 안전을 고려하여 교차로에 인접한 부 도로의 적절한 이격거리를 제시하고자 한다. 교통소통과 안전을 도모할 수 있는 교차로에 인접한 부 도로의 적정길이를 제시함으로써, 향후 교차로에 인접한 부 도로와과 관련된 설치기준 정립에 이바지하고자 한다.

컴퓨터프로그램을 이용한 엘리베이터 피난 연구 (Elevator evacuation studies using a computer program)

  • 차종호
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5525-5533
    • /
    • 2012
  • 최근의 건축물은 초고층화 또는 지하 공간의 심층화되어감에 따라 과도한 수직 거리 이동으로 인하여 체력이 부족한 사람들이 피난층 비상구에 이르기 전에 지쳐서 쓰러질 가능성이 있다. 화재 발생 인접 구역으로부터의 초기 피난에는 계단을 사용한 후에 나머지 거리는 승강기를 이용하여 안전한 공지나 도로로 탈출하는 방법을 요구하고 있다. 이에 따라 서울특별시 초고층 건축물 가이드 라인에서 피난용승강기에 대해 제정되었다. 최근 층수는 지하 7층 지상53층, 바닥면적 $6,800m^2$ 연면적 $127,050m^2$, 용도는 문화 및 집회시설 판매시설 업무시설 숙박시설(호텔) 공동주택(아파트)의 건축물을 설계하면서 피난용승강기를 별도로 설치하기에는 효율적이지 못하다는 판단하에 승용승강기의 설치기준에 따라 설계된 승강기를 피난용으로 사용하기로 결정하였다. 그러나 이에 대한 세부 설계지침내용이 아직까지 마련되어 있지 않아 국내법과 해외 설치기준을 근거로 승용승강기를 피난용으로 이용하기 위한 설계방법을 정리하였으며, 실제 설계된 도면으로 ELVAC+와 PathFinder의 피난프로그램으로 승강기수와 승강기를 이용한 피난자수의 적정성에 대해 연구하였다.

개스분석에 의한 주상변압기의 예방진단에 관한 연구 -자외-가시선 흡수분광광도법에 의한 절연유의 열화도 측정- (A Study on Preventive Diagnosis of the Pole Transformer by Gas Analysis -Measurement of Aging of Insulating Oil by UV-Visible Spectrophotometric Method-)

  • 곽희로;남영우;윤영자;남궁미옥;이동준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권5호
    • /
    • pp.94-100
    • /
    • 1996
  • 자외- 가시선 흡수분광광도법을 적용하여 주상변압기 절연유의 판정기준을 제시하였다. 절연유가 열화하면 절연유의 전기적 특성치가 저하할 뿐만 아니라 흡광도값도 변하게 된다. tan$\delta$와 절연파괴전압과 같은 전기적 특성치를 흡광도값과 비교하여 흡광도값에 의한 절연유의 판정기분을 설정하였다. 흡광도값이 0.580 이하는 양호, 요주의는 0.580~0.900, 불량은 0.900이상이다. 자외-가시건 흡수분광광도법은 절연유의 열화분석에 적용할 수 있으며, 기존의 육안에 의한 절연유 검사 방법을 대체할 수 있을 것으로 기대된다. 그러나 분광광도법을 현장에 적용하려면 저렴하고 경량화된 휴대용 분광광도계의 개발이 필요하다.

  • PDF