• Title/Summary/Keyword: Installation criteria

Search Result 299, Processing Time 0.025 seconds

Heavy Rain and Flood Prevention in Urban (뉴스초점: 집중호우와 도시지역 홍수방어)

  • Jeong, Sun-Gil
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.6
    • /
    • pp.31-34
    • /
    • 2010
  • Recently, due to localized heavy rain and flash floods in urban areas is becoming more frequent flood damage. To prevent flood inundation damage, to formulate the diverse directions in connection with the drainage system of buildings, roads, sewerage, pump stations, detention (retention) pond, and streams is very important. In addition, it is important for the uniform design criteria, the consistent of hydrologic and hydraulic analysis method, and a flood disaster mitigation systems connected with structural and nonstructural measures. To accomplish this, the method such as installation of storage facilities, infiltration facilities, and underground water tank, the optimal size of the design gutter and grate of the road, ensure the capacity of pumping stations, and the installation of a flood control channel into the deep underground requires comprehensive measures dimension in urban areas.

  • PDF

A Study on Approach Method for Standardization of Contruction Specifications and Design Criteria based on Energy Performance of Electrical Installations in Buildings (건축전기설비분야의 에너지절약 요소기술 설계편람 개발)

  • Kim, Se-Dong;Lee, Kwang-Sik;Park, Won-Joo;Choi, Eun-Hyeok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.387-390
    • /
    • 2009
  • 앞으로 국제경쟁력 확보를 위해서는 성능중심의 건설기술기준 적용이 필요하다. 성능중심의 건설기준을 개발하고, 성능계약제도 도입방안을 구축함으로써 시설물의 성능을 향상시키고, 생애주기비용 (LCC)을 절감하며, 설계 및 시공자의 기술개발을 유도하는 것이 필요하다. 본 연구에서는 건축전기설비분야를 중심으로 에너지절약 요소기술을 발굴하고, 설계기준에 기술하기 곤란한 사항, 기술자가 효율적인 업무수행을 위하여 필요한 사항들을 도출하여 실무에 쉽게 활용하도록 설계편람을 작성하는데 있다.

  • PDF

A Study on Reliability Analysis for Reliability Testing & Field Degradation Data of LED Lighting (LED조명기기의 필드 열화데이터에 대한 신뢰성 분석에 관한 연구)

  • Yang, Seong-Yong;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.54-59
    • /
    • 2011
  • LED lightings typically do not fail catastrophically during use. However, over time the light output will gradually depreciate. Even if there are same LED lighting, they are so different at all. because of dissimilar the use and environment of each LED lighting. In this paper, we make a description of reliability analysis procedures for the degradation data using collected field data. Reliability analysis procedures are consisted of estimating degradation models and failure time, verification of distribution and parameters of the distribution, and reliability measures estimation. At some point in time, the light emitted from an LED lightings depreciates to a level where it is no longer considered adequate for a specific application.

Regulation of Common Reception System for Broadcasting Signal (방송 공동수신설비의 설치기준)

  • Her, Young-Tae;Kim, Kwang-Ui;Kwon, Won-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.183-184
    • /
    • 2008
  • From the beginning of a new millennium, the digital broadcasting services had been adopted to cable, satellite and radio broadcasting services as well as the terrestrial TV broadcasting services. The government established the installation standard of digital receiving equipment in 2007, which is needed for taking the new digital broadcasting services without additional facilities in an apartment house. In this paper, I will show the installation standard of digital receiving equipment in an apartment house and give a detailed explanation for the main criteria of it.

  • PDF

The Study based on Comparison with Reliability Assessment Standards for Power LEDs(Light Emitting Diodes) (Power LED의 신뢰성 평가 규격 비교 연구)

  • Park, Chang-Kyu;Cho, Sang-Muk;Lee, Min-Jin;Kim, Jin-Sheon;Kim, Jung-Su;Jeong, Hee-Suk;Lee, Young-Joo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.216-219
    • /
    • 2008
  • The Power LED is more much than 1W and appliable to lights that is different from signal LED. In this paper we investigated types of tests in reliability assessment standards on Power LED. we make comparison of that military standards, JEITA(Japan Electronics and Information Technology Industries Association) and JEDEC(Joint Electron Device Engineering Council) with RS(reliability standard). Reliability tests should be considered that informations can be obtained from requirements of a real system Therefore, The paper aided companies to criteria for reliability tests by themselves.

  • PDF

Design and Experimental Investigation of High-Speed Three-Phase Induction Motor for Turbo Blower

  • Kim, Young-Kwan;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.59-65
    • /
    • 2008
  • High-speed electrical motor has been studied for several applications, i.e. for direct-drive systems of centrifugal compressors and turbo blowers. This paper deals with a design consideration of electromagnetic, mechanical and thermal limits of high-speed induction motor for turbo blower. Basic design concept of high-speed motor was proposed. As the motor is to be operated at high speed, the losses are quite different from conventional low-speed machines. Especially, the increases of rotor eddy current and friction losses could lead to an overheated motor. So, we suggested a special cooling system to reduce temperature rise. And, based upon this design concept, the prototype induction motor(37[kW], 45,000[rpm]) for high-speed turbo blower was designed and 2-D electromagnetic field analysis was implemented. Finally, criteria to evaluate the characteristics of high-speed induction motor have been proposed and tested.

Short-term Load Forecasting of Using Data refine for Temperature Characteristics at Jeju Island (온도특성에 대한 데이터 정제를 이용한 제주도의 단기 전력수요 예측)

  • Kim, Ki-Su;Song, Kyung-Bin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.225-228
    • /
    • 2008
  • The electricity supply and demand to be stable to a system link increase of the variance power supply and operation are requested in jeju Island electricity system. A short-term Load forecasting which uses the characteristic of the Load is essential consequently. We use the interrelationship of the electricity Load and change of a summertime temperature and data refining in the paper. We presented a short-term Load forecasting algorithm of jeju Island and used the correlation coefficient to the criteria of the refining. We used each temperature area data to be refined and forecasted a short-term Load to an exponential smoothing method.

  • PDF

A Study on Approach Method for Standardization of Construction Specifications and Design Criteria based on Energy Performance of Electrical Installations in Buildings (건축전기설비분야의 에너지성능기준 개발 접근방법에 관한 연구)

  • Kim, Se-Dong;Lee, Kwang-Sik;Choi, Eun-Hyeok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.341-344
    • /
    • 2008
  • 앞으로 국제경쟁력 확보를 위해서는 성능중심의 건설기술기준 적용이 필요하다. 성능중심의 건설기준을 개발하고, 성능계약제도 도입방안을 구축함으로써 시설물의 성능을 향상시키고, 생애주기비용(LCC)을 절감하며, 설계 및 시공자의 기술개발을 유도하는 것이 필요하다. 본 연구에서는 건축전기 설비분야의 에너지성능 기준 개념과 외국의 도입사례를 살펴보고, 에너지성능기준 개발 대상 및 범위를 설정하고 성능기준 개발을 위한 접근방법을 도출하였다.

  • PDF

A Safety Assessment of a Mesh Grounding System for 22.9kV Substations (22.9kV 수전설비 Mesh 접지설계의 안전성 평가 사례)

  • Park, Sang-Gyo;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.54-60
    • /
    • 2013
  • There is increasing demand for practical groundings for small-area substations because of the recent revision of Korea's Electrotechnical Regulations, which necessitates the method of evaluating their safety. This paper proposes a practical mesh grounding system for 22.9kV substations and studies how to evaluate its safety. The proposed grounding system is proved to obey the safety criteria of ANSI/IEEE Std. 80 via ANSI/IEEE Std. 80 method and computer simulation.

Development of Optimum Design Technology of Platform Screen Door Systems for the Environment Improvement and Disaster Prevention of Urban Railway (도시철도 환경개선 및 방재를 위한 스크린도어시스템 최적설계기술 개발)

  • Kim, Jung-Yup
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.84-87
    • /
    • 2008
  • In order to maximize the effect of installing screen door system while to minimize the problems in an initial stage of introduction, it is strongly required to research an optimum installation solution in connection with ventilation and disaster prevention system alongside with safety structure analysis of screen door in respect to train-induced wind, as well as to develop the criteria for the operation after the installation. This paper presents the results of study to develop the optimum design technology in urban railway equipped with platform screen door systems.

  • PDF