• Title/Summary/Keyword: Installation criteria

Search Result 299, Processing Time 0.034 seconds

Investigation of touchdown point mismatch during installation for catenary risers

  • Huang, Chaojun;Hu, Guanyu;Yin, Fengjie
    • Ocean Systems Engineering
    • /
    • v.8 no.3
    • /
    • pp.313-327
    • /
    • 2018
  • Meeting the touchdown point (TDP) target box is one of the challenges during catenary riser installation, especially for deep water or ultra-deep water riser systems. TDP location mismatch compared to the design can result in variation of riser configuration, additional hang-off misalignment, and extra bending loads going into the hang-off porch. A good understanding of the key installation parameters can help to minimize this mismatch, and ensure that the riser global response meets the design criteria. This paper focuses on investigating the potential factors that may affect the touchdown point location, and addressing the challenges both in the design stage and during installation campaign. Conventionally, the vessel offset and current are the most critical factors which may affect the TDP movement during installation. With the offshore exploration going deeper and deeper in the sea (up to 10,000ft), other sources such as the seabed slope and seabed soil stiffness are playing an important role as well. The impacts of potential sources are quantified through case studies for steel catenary riser (SCR) and lazy wave steel catenary riser (LWSCR) in deep water application. Investigations through both theoretical study and numerical validation are carried out. Furthermore, design recommendations are provided during execution phase for the TDP mismatch condition to ensure the integrity of the riser system.

A Pilot Study on Installation Criteria of Speed Change Lanes according to the Implementation of Safety Speed "5030" in the Urban Area (도심내 안전속도 "5030"시행에 따른 변속차로 설치기준에 관한 기초연구)

  • Oh, Seok-Jin;Ha, Tae-Jun;Jin, Tae-Hee;Shin, Kwang-Min;Lee, Gang-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.57-64
    • /
    • 2021
  • The speed change lane is installed at the point where the roads are connected on the urban roads, reducing the relative speed to facilitate traffic communication. However, in the case of the speed limit of 30 km/h in accordance with the implementation of the safe speed "5030" in the city, the standard is ambiguous, and there are criticisms about the installation of the transmission lane. This study conducted a pilot study on the traffic patterns of the speed change lanes, focusing on the section where the safe speed "5030" policy was scheduled to be implemented after theoretical consideration of the speed change lanes. After on-site investigation, as a result of analyzing the traffic pattern according to the travel speed of the main road according to road conditions and traffic conditions, the effectiveness of the speed change lane according to the safety speed "5030" was analyzed. In this study, the installation criteria for speed change lane by speed were presented. The criteria is that "speed change lanes should not be installed when the speed limit is 30 km/h, and speed change lanes should be installed when the speed limit is 50 km/h." The criteria will be considered as a reference when establishing engineering standards for connection of other facilities in urban areas in the future. It is expected that unnecessary restrictions on individuals' exercise of private property rights will be minimized, smooth traffic flow and secure safety by the installation of speed change lanes and expansion of turning radius.

A Study on the Calculation of Transmission Current-Carrying Capacity by Horizontal Arrangement Type in the Installation Methods of 154kV XLPE 600㎟ Power Cable Buried Ducts in Ground (154kV XLPE 600㎟ 지중관로 수평배열 형태별 허용전류용량 산정에 관한 연구)

  • Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.53-58
    • /
    • 2016
  • The underground transmission lines which have been built to expand the suppling facilities will be continuously accompanying with high growth of the increase of power demand in the metropolitan area in recent years. So, it is necessary to maximize the ability and reliability of power supply with the current-carrying capability of the underground transmission lines. Design criteria of KEPCO is to be presented and used frequently. But it has to be studied about the installation methods of power cable buried in ground. In this study, we used the program for calculating the current-carrying capability of underground transmission power cables. We estimated the maximum permissible current values by the horizontal arrangement in the installation methods of power cable(154kV XLPE $600mm^2$) buried ducts in ground. To see the general tendency of the analysis, we researched a statistical analysis with such parameters as the maximum permissible current values. Through the regression analysis, we analyze the most highly values of the maximum permissible current on the Ra type duct arrangement.

A Study on the Test and Installation Standards of the Video Fire Detector (영상화재감지기 시험과 설치기준에 관한 연구)

  • Lee, Jeong-Hyun;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.1-5
    • /
    • 2016
  • This research performed tests of Video Fire Detector and criteria of installation to make suggestions regarding the criteria that must be reflected in NFSC 203 by comparing the standards of FM Approvals, UL, ISO7240 and NFPA 72. FM Standard related to Video Fire Detector test has been classified as Smoke, Flame type, but the UL Standard has classified only as a Smoke type. This research examined 6 cases of fire phenomenon detection case in ISO 7240 and 3 cases in NFPA 72, respectively. There are 15 items required for the installation standard of a Video Fire Detector and each field standard is presented as a per installation method. To apply a Video Fire Detector, the pertinent items (the definition of term, detector's classification, structure and function among its test item) must be inserted. In addition, 7 items of the fire test, i.e., the sensitivity adjustment, prevent false alarm, ambient temperature test, the effective sensitivity and detection distance and viewing angle, aging test, flood test, must be applied to the actual test. For installation in the field, the operation environment and levels of illumination, and NFSC 203 must be set, and standards relevant to the sound system, indicators' installation distance, etc. need to be inserted.

A Study of Determining Priorities of RWIS Installation (RWIS 설치를 위한 우선순위 선정 기법에 관한 연구)

  • Yang, Choong Heon;Kim, In Su;Jeon, Woo Hoon
    • International Journal of Highway Engineering
    • /
    • v.14 no.6
    • /
    • pp.175-182
    • /
    • 2012
  • PURPOSES : This paper presents how to determine priorities of RWIS installation on national highways within the limited budget. METHODS : Analytical hierarchy process was employed to develop the entire methodology. In addition to this, various data such as vulnerable roadway section for snow removal, RWIS, AWS, AADT, and traffic accident were properly collected and analyzed for the future analysis. Then, GIS analysis was performed to find out the final candidate vulnerable roadway section for snow removal. In the end, expert survey was conducted to estimate weights for evaluation criteria. RESULTS : Results showed that metropolitan area has the most high priority, and Gangwon area, ChungCheung, and Honam in order. CONCLUSIONS : The main contribution of this paper is to suggest a logical methodology to prioritize RWIS installation within the limited budget, and thus snow removal operation during the winter season can improve in terms of getting more valuable information.

Design criteria of wind barriers for traffic -Part 2: decision making process

  • Kim, Dong Hyawn;Kwon, Soon-Duck;Lee, Il Keun;Jo, Byung Wan
    • Wind and Structures
    • /
    • v.14 no.1
    • /
    • pp.71-80
    • /
    • 2011
  • This study presents a decision making process for installation of wind barrier which is used to reduce the wind speed applied to running vehicles on expressway. To determine whether it is needed to install wind barrier or not, cost and benefit from wind barrier are calculated during lifetime. In obtaining car accidental risk, probabilistic distribution of wind speed, daily traffic volume, mixture ratio in the volume, and duration time for wind speed range are considered. It is recommended to install wind barrier if benefit from the barrier installation exceed construction cost. In the numerical examples, case studies were shown for risk and benefit calculation and main risky regions on Korean highway were all evaluated to identify the number of installation sites.

Solid Culture Medium Selection Criteria for Hydroponics Farm Households (양액재배 농가의 고형배지 선택 기준에 관한 연구)

  • Kim, Dong-Seok;Kim, Dae-Young;Hwang, Jae-Hyun;Yun, Hoa-Young
    • Korean Journal of Organic Agriculture
    • /
    • v.22 no.4
    • /
    • pp.841-854
    • /
    • 2014
  • This study aimed to analyze the selection criteria and priority settings for solid culture medium used in hydroponic crop production in farm households. Expert brain storming was carried out to extract solid culture medium selection criteria for hydroponic farming. As a result, 3 criteria of economy (cost), productivity, and environment, and 9 factors were extracted. A questionnaire survey of hydroponic farm households was conducted in Gyeonggi, Gangwon, and Chooncheong provinces. AHP analysis of the hydroponic solid culture medium selection criteria identified productivity as the most important criterion, chosen by 58.7% of the respondents, followed by economy (28.4%) and environment (12.9%). The 9 factors were rated by the respondents in the following decreasing order of importance: 1, crop yield (28.3%); 2, pest occurrence (18.5%); 3, maintenance/management costs (12.0%); 4, convenience of maintenance/management (13.4%); 5, initial investment cost (11.6%); 6, material energy consumption (6.5%); 7, waste recyclability (4.0%); 8, waste disposal costs (3.4%); and 9 environmental emissions (1.81%). These results imply that hydroponic farm households consider cultivation-related quality factors more important than economic factors, such as price of culture medium or installation cost.

The Optimized Standards and Criteria for Installing Switches on Distribution Feeder (국내 배편계통의 최적 개폐기 설치 기준)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.238-246
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in stun dards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches Is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

A Study on the Grounding Resistance Effects of Power Transformer in Electric Distribution Systems (배전계통에서 전력용 변압기의 접지저항 영향에 관한 연구)

  • Kim, Kyung-Chul;Jung, Ji-Won;Lee, Kyu-Jin;Lee, Kang-Soo;Choi, Sun-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.113-119
    • /
    • 2010
  • A safe grounding design is used for providing means to carry electric currents into the earth under fault conditions without exceeding any operating limits and for assuring that a person in the vicinity of grounded facilities is not exposed to danger of critical electrical shock. Transformer neutral point grounding is for the purpose of controlling the voltage to earth within tolerable limits under a line-to-ground fault. Transformer frame grounding is for the purpose of minimizing the hazardous potential within safety criteria appearing at the faulted equipment. ills paper deeply investigates the grounding resistance effects of distribution power transformers by analysing the neutral to eatth voltages and touch voltages when the fault occurs.