• Title/Summary/Keyword: Inside-out method

Search Result 481, Processing Time 0.082 seconds

Interior noise prediction of the high speed train using ray method (광음향기법을 이용한 한국형 고속전철의 실내소음 예측)

  • 김관주;박진규
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.157-164
    • /
    • 2000
  • This study is about predicting the interior pressure level of the korean high speed train using ray acoustic method. The motor car and the motor and passenger cabin are investigated under the environment of passing open countryside and inside tunnel of 350 km/hr. Calculated sound levels are compared with the proposed sound levels and suggestions about the transmission Joss values of isolating panels inside motor car and the guide lines of allowed sound power limit of motor equipments are provided. Results of TPI car show calculated interior sound level is below the proposed values for both cases of open countryside running and inside tunnel. Since ray acoustic method calculated only air borne noise component, real sound level of the motor car may be higher than prediction. Passenger cabins of TMI, TM5 show higher sound level than the proposed values, so window method was carried out to find the contribution of each panel components and point out the remedy of transmission path. Reduction of sound power of motor equipments should be condisered at the same time.

  • PDF

Results of Arthroscopic inside to Out Repair of Meniscus Tear (반월상연골 파열에 대한 관절경적 inside to out 봉합술의 결과)

  • Kim, Bo-Hyun;Hwang, In-Sung;Yun, Tae-Bong;Byun, Jae-Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Purpose: This study examined clinical cure and patients' satisfaction degrees by factors influencing surgical operation results, after arthroscopic inside to out repair as a nonabsorbable suture material, in case of meniscal rupture. Materials and Methods: Materials were 110 cases of 95 patients who could make paces for over 12 months from August 1999 to June 2002. Results were evaluated by clinical cure and subjective satisfaction degrees. This study, concerning those results, analyzed age, term from taking pictures to taking surgical operation, rupture section, rupture length, rupture types, lesion of articular-cartilage, and effects of anterior cruciate ligament operation accompanied. Results: 84 cases(76%) were clinically cured, 98 cases(89%) were subjectively satisfied. In case of accompanying anterior cruciate ligament rupture, and in case that rupture length was below 2 cm, rates of clinical cure and patients subjective satisfaction were significantly high. In case of complex or degenerative rupture, patients satisfaction rates were higher when comparing with clinical cure rates. Conclusion: Various sutures are possible as well as available in case of arthroscopic meniscal inside to out repair using nonabsorbable suture material. It can be concluded that patients age is not absolte consideration in determining the suture of meniscus. In cases of complex rupture, degenerative rupture, ruptures companied by joint-cartilage injuries, considerate consideratin need be paid to choose patients and operations.

  • PDF

A study on the Measurement of Internal Defects of Pressure Vessel by using ESPI Methods (ESPI 방법들을 이용한 압력용기 내부 결함 측정에 관한 연구)

  • LEE J.S;Kang Y.J.;Baik S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1803-1807
    • /
    • 2005
  • The pipe which it uses from the nuclear power plant or factory by a long period use and a corrosive action the inside defect occurs on the inside. abstract here. The ESPI method is in order to investigate the laser light in the measurement object it will be able to measure the wide territory whole in once, does not receive an effect in direction of defect not to be, has the strong point it will be able to measure a change of place arrowhead real-time defect. It measured a inside defect of pressure vessel by using Out of plane ESPI and In plane of ESPI. It compared a each method result.

  • PDF

Computational study on turbulent flows inside the duct of marine waterjet propulsor (선박 워터제트 추진기 덕트 내부의 난류유동 해석에 관한 연구)

  • Park Il-Ryong;Kim Wu-Joan;Ahn Jong-Woo;Kim Ki-Sup
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.181-184
    • /
    • 2002
  • CFD calculations are carried out to investigate the turbulent flow characteristics inside the duct of marine waterjet propulsors. The Reynolds-averaged Wavier-Stokes equations are solved using a finite-volume method. Standard $k-{\varepsilon}$ model and realizable $k-{\varepsilon}$ model are evaluated with an existing experimental data. Multi-block grid topology is adopted to describe the details of complex duct geometry. The present numerical methods are applied to the preliminary duct design of new waterjet propulsor system. Four different influx conditions are simulated to find out pressure and velocity distribution inside the intake duct. Attention is also paid upon the possible flow separation inside the waterjet duct. It is found that CFD tools can be used for the initial evaluation of inflow condition into the impeller of waterjet propulsor system.

  • PDF

A study on waterproofing method using waterproofing sheet Top-Down method in underground structure (지하 구조물에 적용되는 역타설용 방수시트재의 성능 평가에 관한 연구)

  • Song Je- Young;Kwak Kyu-Sung;Kim Jeoung-Il;Oh Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.301-304
    • /
    • 2005
  • The waterproofing in slab and wall of underground structure, have a couple of construction methods which are inside waterproofing methods for inner surface, and outside waterproofing methods for out wall and slab surface waterproofing. In resent years, however, it has been adapted the inside waterproofing construction method, as increasing of construction expenses cost and low workability and technology, nevertheless, outside waterproofing has set a most high value construction method. In inside waterproofing construction method, it is difficult to repair and assure durability and safety for concrete which has direct water-press. So, It is necessary for adopt the outside waterproofing method.

  • PDF

An Experimental Study on Flow Structure inside a Display Cooler Using PIV Techniques (PIV기법을 이용한 전시용 냉장기의 내부 유동장 측정)

  • Park, Cheol-Woo;Baek, In-Je
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.48-55
    • /
    • 2007
  • Flow structure inside a refrigerating compartment of a scale-down display cooler model was investigated experimentally by using PIV (particle image velocimetry) method, a reliable velocity field measurement technique, in the present study. In addition, we also carried out flow visualization regarding flow structure and particle movement inside a display cooler by using a tracer method. As a result, the mean velocity field measurement shows a large scale vortical flow structure inside a refrigerating compartment due to strong entrainment flow, going through a base plate open gaps.

Purification and Sidedness of Sarcolemma from Canine Ventricle (개 심실 형질막의 분리 및 그 방향성에 관한 연구)

  • 이신웅;구정옥;이정수
    • YAKHAK HOEJI
    • /
    • v.30 no.1
    • /
    • pp.31-41
    • /
    • 1986
  • Sarcolemmal membrane fraction from canine ventricle was isolated from the discarded pellet after the first homogenization in the isolation procedure of sarcoplasmic reticulum (Method 1) and the protein yield, purity, and sidedness of this preparation were compared to those of sarcolemmal fraction prepared by method of Lee et al. (Method 2) and a slight modification of original protocol of Jones et al. (Method 3). Method 1 differed from Method 2 essentially only in that vigorous homogenization was carried out by omnimixer and homogenization medium containing 30mM Tris-maleate was used in the first step. The sarcolemmal fraction was enriched from 45 to 50 and 29-fold in [$^3H$] ouabain, [$^3H$] DHA, [$^3H$] QNB binding and $Na^+$, $K^+$-ATPase activity, respectively, compared to homogenate. Total $Na^+$, $K^+$-ATPase activity of highly sarcolemma enriched fraction was 144.6$\pm$16.4$\mu\textrm{mol}$ Pi/mg protein/hr, which was about 85%, of total ATPase activity, and the yield of the preparation was 15.7 mg protein per 100g of starting ventricular tissue. The sarcolemmal preparation supported $^{45}Ca^{2+}$-uptake in the presence of ATP but this uptake was not dependent on oxalate. Sarcolemmal $Na^+$, $K^+$-ATPase activity and detectable [$^3H$] ouabain binding were increased about 32% and 35%, respectively, by pretreatment of sarcolemmal fraction with optimal concentration of sodium dodecylsulfate (0.3-0.4mg/mg protein), suggesting that this preparation contained about 24% of sealed rightside-out vesicles, 26% of sealed inside-out vesicles, and 5001o of freely permeable (leaky) form. This procedure showed the highest protein yield and leaky population, compared to Method 2 and 3. On the other hand, sarcolemmal fraction prepared by Method 2 and 3 showed low value in protein yield but comtained high population of inside-out (46%) and rightside-out (49%) vesicles, respectively, compared to present procedure (Method 1). The results indicate that vigorous homogenization decreases the population of sealed sarcolemmal vesicles but increases the sarcolemmal protein yield per gram tissue and that this procedure is available for further purification of sarcolemmal fraction and for the receptor binding study of sarcolemma.

  • PDF

Analysis of Water Storage Tank Flowfield using Computational Fluid Dynamics (CFD) Simulation (전산유체역학(CFD)을 이용한 저수조 내부 유동장 해석)

  • Choi, Yeon-Woo;Han, Min-Su;Song, Jun-Hyuck;Wang, Chang-Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.173-182
    • /
    • 2018
  • Reservoirs, facilities to store water, are being used in several fields for their ability to hold back a large quantity of water for a long time before the water is actually used. However, at the same time, the reservoirs are considered to have a flaw: the longer they store water, the more the quality of water in these reservoirs deteriorates. Further, when the reservoirs are large, they are more likely to have dead-water regions in out-of-the way spots far from either an in-current or an ex-current canal. This study conducted a Computational Fluid Dynamic (CFD) simulation and tried to figure out the internal flow inside each of the reservoirs with different in-current canals built by the multiple hoe screw nozzle method and the drop in-current method. The drop in-current method is more frequently used. According to the analysis of the internal flow inside each reservoir with the different methods applied, we found that the reservoir with the drop in-current canal would have two rotary currents in the lower region of the reservoir and that the velocity of flow would decrease. For a reservoir with the screw nozzle method, a single rotary current occurred, and inside the reservoir, regardless of height, the current turned out to flow in a regular manner.

An Experimental Study on Improvement in Waterproofing Performance of Ground Structures applied to Synthetic Polymeric Sheet of monolithic adhesion Type (일체부착형 합성고분자 시트를 이용한 지하구조물 방수 성능향상에 관한 실험적 연구)

  • Kang, Hyo-Jin;Song, Jei-Young;Kwon, Shi-Won;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.3 s.17
    • /
    • pp.125-129
    • /
    • 2005
  • The waterproofing in slab and wall of underground structure, have a couple of construction methods which are inside waterproofing methods for inner surface, and outside waterproofing methods for out wall and slab surface waterproofing. In resent years, however, it has been adapted the inside waterproofing construction method, as increasing of construction expenses cost and low workability and technology, nevertheless, outside waterproofing has set a most high value construction method. In inside waterproofing construction method, it is difficult to repair and assure durability and safety for concrete which has direct water-press. So, It is necessary for adopt the outside waterproofing method. For that reasons, this study based on the application for outside waterproofing method on the under ground structure, to more increase durability, to introduce mono adhesive sheet waterproofing materials. as considering chemical, physical properties.