• Title/Summary/Keyword: Inside out

Search Result 1,951, Processing Time 0.034 seconds

Results of Arthroscopic inside to Out Repair of Meniscus Tear (반월상연골 파열에 대한 관절경적 inside to out 봉합술의 결과)

  • Kim, Bo-Hyun;Hwang, In-Sung;Yun, Tae-Bong;Byun, Jae-Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Purpose: This study examined clinical cure and patients' satisfaction degrees by factors influencing surgical operation results, after arthroscopic inside to out repair as a nonabsorbable suture material, in case of meniscal rupture. Materials and Methods: Materials were 110 cases of 95 patients who could make paces for over 12 months from August 1999 to June 2002. Results were evaluated by clinical cure and subjective satisfaction degrees. This study, concerning those results, analyzed age, term from taking pictures to taking surgical operation, rupture section, rupture length, rupture types, lesion of articular-cartilage, and effects of anterior cruciate ligament operation accompanied. Results: 84 cases(76%) were clinically cured, 98 cases(89%) were subjectively satisfied. In case of accompanying anterior cruciate ligament rupture, and in case that rupture length was below 2 cm, rates of clinical cure and patients subjective satisfaction were significantly high. In case of complex or degenerative rupture, patients satisfaction rates were higher when comparing with clinical cure rates. Conclusion: Various sutures are possible as well as available in case of arthroscopic meniscal inside to out repair using nonabsorbable suture material. It can be concluded that patients age is not absolte consideration in determining the suture of meniscus. In cases of complex rupture, degenerative rupture, ruptures companied by joint-cartilage injuries, considerate consideratin need be paid to choose patients and operations.

  • PDF

Phenomenological References : Arguments for Mentalistic Natural Language Semantics

  • Jun, Jong-Sup
    • Language and Information
    • /
    • v.8 no.2
    • /
    • pp.113-130
    • /
    • 2004
  • In a prevailing view of meaning and reference (cf. Frege 1892), words pick out entities in the physical world by virtue of meaning. Linguists and philosophers have argued whether the meaning of a word is inside or out-side language users' mind; but, in general, they have taken it for granted that words refer to entities in the physical world. Hilary Putnam (1975), based on his famous twin-earth thought experiment, argued that the meaning of a word could not be inside language users' head. In this paper, I point out that Putnam's argument makes sense only if words refer to entities in the physical world. That is, Putnam did not provide any argument against mentalistic semantics, since he erroneously assumed that meaning, but not reference, was inside our mind in mentalistic semantics. Mentalistic semanticist, however, assume that words pick out their references inside our head (instead of a possible outside world). A number of arguments for the mentalistic position come from psychology: studies on emotion and visual perception provide numerous cases where words cannot pick out entities from the physical world, but inside our head. The mentalistic theory has desirable consequences for the philosophy of language in that some classical puzzles of language (e.g. Russell's (1919) well-known puzzle of excluded middle) are explained well in the proposed theory.

  • PDF

Construction of Magnetic Resonance Imaging Inside-out probes for Internal Imaging (핵자기공명 영상법을 위한 내부 영상용 뒤집음-탐침의 제작)

  • Ko, R.K.;Lee, D.H.;Jeong, E.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.78-81
    • /
    • 1995
  • In imaging the samples or human internal organs in a tube shape, general RF-probe types (that encircles a sample or places on top of the sample) are usually unsuitable for the internal imaging due to the degradation of signal-to-noise ratios(SNR's). In the present study the inside-out probes for Magnetic Resonance Imaging (MRI) have been constructed in the three different shapes such as an anti-solenoidal, a saddle and a dual surface types which are positioned as close to the area as possible by putting the probe inside the tubelike sample to improve filling factor. RF-field distributions have also been calculated depending upon the geometrical changes of anti-solenoid probes. Moreover, the performance of the inside-out probes has been checked by measuring SNR's of the images acquired. The inside-out probes constructed in this study produced better SNR's and rf-field uniformity in the area close to the probes in comparing with any other commercial probes. There is a high possibility that the constructed probes in the present study are applicable to the diagnosis of human bodies.

  • PDF

Modified Inside-Out Suture Technique for Meniscus Repair (변형된Inside-Out 술식을 이용한 반월상 연골 봉합술)

  • Ahn Jin-Hwan;Wang Joon-Ho;Yoo Jae-Chul;Kim Hyung-Gun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.2
    • /
    • pp.118-123
    • /
    • 2002
  • Purpose: To report modified technique of inside-out suture in repair of tear of postero medial corner of medial meniscus. Operative technique: Arthroscope is placed through anterolateral portal. Suture hook is delivered through anteromedial portal. By rotating the suture hook, it penetrates the inner portion of the torn meniscus from femoral surface to tibial surface of the meniscus for vertically oriented suture. A PDS suture is delivered through the lumen of suture hook, and the suture hook is withdrawn. The both ends of the suture are retrieved through anteromedial portal by a retriever, either grasper or crochet hook.A Zone-specific cannula is positioned below the inferior surface of the meniscus through anterolateral portal. The Looped Needle designed by the authors is delivered through the lumen of the Zone-specific cannula. The suture end of the tibial surface is placed in the loop of the Looped Needle and pulled out to the surface of posteromedial joint line. The suture end of the femoral surface is pulled out in same manner. A transverse skin incision of 1cm size is made adjacent to pulled out suture and the suture is tied. Discussion: Even though modified inside-out suture technique requires longer operation time than conventional inside-out technique, it provides vertically oriented suture and good tissue coaptation. The authors recommend this modified inside-out suture technique to be good alternative in repairing tear of the posteromedial corner of medial meniscus.

  • PDF

All-Inside Meniscal Repair (All-Inside 반월연골판 봉합술)

  • Choi, Nam-Hong;Kim, Byeong-Yeon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.12 no.1
    • /
    • pp.8-15
    • /
    • 2013
  • Although total meniscectomy had been performed as a treatment of meniscal tear, many published articles reported progression of the degeneration process in the articular cartilage and development of the osteoarthritis after meniscectomy. With the increased knowledge of the biomechanical properties of the meniscus, meniscal repair has been performed increasingly to maintain the important functions of the meniscus. Outside-in, inside-out, all-inside technique have been used as meniscal repair methods. In this review, indications, operative technique, and outcomes of the all-inside meniscal repair are discussed.

  • PDF

The Fate of Nonabsorbable Sutures in Arthroscopic Inside-Out Meniscus Repair - A Case Report - (관절경적 Inside-Out 반월상 연골 봉합술에서 비흡수성 봉합사의 운명 - 1예 보고 -)

  • Ahn, Jin-Hwan;Lee, Dong-Hoon;Chang, Moon-Jong;Seo, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.54-58
    • /
    • 2007
  • Either absorbable or nonabsorbable sutures can be used in meniscal repair. Some surgeons prefer nonabsorbable sutures because they believe that nonabsorbable sutures improve meniscal healing as compared with absorbable sutures. But, permanent existence of sutures in the lesion could make problems. We report a case of Inside-Out meniscus repair that nonabsorbable sutures came out of the joint capsule tearing the substance of the meniscus.

  • PDF

Film Flow Analysis for a Vertical Evaporating Tube with Inner Evaporation and Outer Condensation (내부와 외부에서 증발과 응축이 발생하는 수직관에 대한 유동 해석)

  • Park, Il-Seouk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.8
    • /
    • pp.621-628
    • /
    • 2008
  • A numerical study for the flow, heat and mass transfer characteristics of the evaporating tube with the films flowing down on both the inside and outside tube walls has been carried out. The condensation occurs along the outside wall while the evaporation occurs at the free surface of the inside film. The transport equations for momentum and energy are parabolized by the boundary-layer approximation and solved by using the marching technique. The calculation domain of 2 film flow regions (evaporating and condensation films at the inside and outside tube wall respectively) and tube wall is solved simultaneously. The coupling technique for the problem with the 3 different regions and the 2 interfaces of them has been developed to calculate the temperature field. The velocity and temperature fields and the amount of the condensed and evaporated mass as well as the position where the evaporating film is completely dried out are successfully predicted for various inside pressures and inside film inlet flow rates.

Magnetic Resonance Imaging of Lumen Wall using Quadrature-typed Inside-out Receiver Coil (회전자계 역수신 코일을 이용한 관벽의 자기공명 영상)

  • 문치웅;조종운
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.385-392
    • /
    • 2001
  • This study Proposes a quadrature-typed inside-out receiver coil to obtain magnetic resonance(MR) images of lumen wall. This means that the coil should receive the signals from out-side of receiver coil. This coil has wide and uniform sensitive region to compare with previous coils such as anti-solenoid coil, octal-pole coil and so on. These coils have the disadvantages that sensitive region is narrow and inhomogenous. The proposed coil is consist of two saddle coils of which directions are orthogonal to one another. The sensitivity maps of octal-Pole coil single-saddle coil and quadrature-typed inside-out coil were obtained by computer simulation. And phantom images for each coil were obtained to evaluate the performances of the coil using both 1.5T superconducting and 0.3 Permanent magnet MRI system. The uniformity of quadrature coil's sensitivity map was superior to that of octal-polel coil. Experimentally measured SNR of quadrature coil is also 36% higher than that of single-saddle coil This study shows the possibility of quadrature-typed inside-out receiver coil for the MR lumen wall images.

  • PDF

The Intermedial Relationship between the Animations, and (애니메이션 <인사이드 아웃>과 <센과 치히로의 행방불명>에서 나타난 상호매체성 관계)

  • Lim, Yong-Seob
    • Cartoon and Animation Studies
    • /
    • s.43
    • /
    • pp.103-122
    • /
    • 2016
  • Inside Out(2015) and The Spiriting Away of Sen And Chihiro(2001) have similar narrative structures and scenes. This paper aimed to compare and analyze the intermedial relationship between the two animations. The result of the study showed intermedial relationship between Inside Out and The Spiriting Away of Sen And Chihiro, which was produced and released about 14 years before. However, it was hard to say the former referred to the system of the latter and adopted it. When seen from the narrative structure of exposition, development, crisis, climax, resolution, in Inside Out, various motifs of The Spiriting Away of Sen And Chihiro were restructured, creating a new feeling. This study considered intermediality as something that a single medium overcomes limitations and is transformed through materials, or media, and an important way to provide consumers with contents of better quality, and using Rajewsky's frame of analyzing intermediality, compared and analyzed the relationship of the two animations.

Computational study on turbulent flows inside the duct of marine waterjet propulsor (선박 워터제트 추진기 덕트 내부의 난류유동 해석에 관한 연구)

  • Park Il-Ryong;Kim Wu-Joan;Ahn Jong-Woo;Kim Ki-Sup
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.181-184
    • /
    • 2002
  • CFD calculations are carried out to investigate the turbulent flow characteristics inside the duct of marine waterjet propulsors. The Reynolds-averaged Wavier-Stokes equations are solved using a finite-volume method. Standard $k-{\varepsilon}$ model and realizable $k-{\varepsilon}$ model are evaluated with an existing experimental data. Multi-block grid topology is adopted to describe the details of complex duct geometry. The present numerical methods are applied to the preliminary duct design of new waterjet propulsor system. Four different influx conditions are simulated to find out pressure and velocity distribution inside the intake duct. Attention is also paid upon the possible flow separation inside the waterjet duct. It is found that CFD tools can be used for the initial evaluation of inflow condition into the impeller of waterjet propulsor system.

  • PDF