• Title/Summary/Keyword: Inside diameter

Search Result 738, Processing Time 0.027 seconds

The Minimum Fluidization Velocity of Gaussian Distribution Particle System According to Standard Deviation (Gaussian 분포의 입자군의 표준편차에 따른 최소유동화속도)

  • Jang, Hyun Tae;Park, Tae Sung;Cha, Wang Seog
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.567-570
    • /
    • 2008
  • The present study investigated the applicability of the minium fludization velocity measuring method using linear regression analysis between the standard deviation of pressure fluctuation and gas velocity in multi-particle sand on a fluidized bed 0.109 in inner diameter. We measured minium fludization velocity according to the standard deviation of particle distribution in Gaussian distribution. The measured value compared with other researchers' equations. The minium fludization velocity derived from the linear regression analysis of the standard deviation of pressure fluctuation and pressure drop inside the bed. We also found that the minium fludization velocity of a multi-particle system using the standard deviation of pressure fluctuation must be measured at freely bubbling region.

Analysis of Operation Parameters of Pilot-Scale Packed-Absorption System for Airborne Methyl Ethyl Ketone Control (공기 중 메틸에틸케톤 제어를 위한 Pilot-Scale 흡수 시스템의 운영인자 분석)

  • Jo, Wan-Kuen;Kim, Wang-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2011
  • Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm ${\times}$ height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).

Implementation of High-Quality Si Integrated Passive Devices using Thick Oxidation/Cu-BCB Process and Their RF Performance (실리콘 산화후막 공정과 Cu-BCB 공정을 이용한 고성능 수동 집적회로의 구현과 성능 측정)

  • 김동욱;정인호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.509-516
    • /
    • 2004
  • High-performance Si integrated passive process was developed using thick oxidation process and Cu-BCB process. This passive process leads to low-cost and high-quality RF module with a small form factor. The fabricated spiral inductor with 225 um inner diameter and 2.5 turns showed the inductance of 2.7 nH and the quality factor more than 30 in the frequency region of 1 ㎓ and above. Also WLCSP-type integrated passive devices were fabricated using the high-performance spiral inductors. The fabricated low pass filter had a parallel-resonance circuit inside the spiral inductor to suppress 2nd harmonics and showed about 0.5 ㏈ insertion loss at 2.45 ㎓. And also the high/low-pass balun had the insertion loss less than 0.5 ㏈ and the phase difference of 182 degrees at 2.45 ㎓.

Inchworm-Like Robotic Colonoscope UsingLegs for Clamping (다리를 이용한 클램핑 방식의 자벌레 이동방식 대장내시경로봇)

  • Park, Hyun-Jun;Leem, Sang-Hyuck;Kim, Byung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.789-795
    • /
    • 2010
  • For the reliable clamping of a robotic colonoscope inside the colon, we propose a clamping module consisting of six legs at the front and a trigger at the rear. In addition, a pneumatic-line based locomotive mechanism, which was developed previously for in-pipe inspection, is adopted to reduce the friction force between the pneumatic lines and the locomotion environment. In order to evaluate locomotion performance, a robot with a diameter of 15 mm and a length of 110.250 mm is used. Based on control signal from LabVIEW, it is tested in acrylic pipe and pig's colon. The proposed robot is able to move in the curved path which has a radius of over 25 mm. The speed of the robot is 33 mm/s in a straight path and 12.1 mm/s on a vertical path. The proposed robot, which has one pneumatic line and two clamping modules, conclusively shows reliable locomotion performance under in vitro condition.

Parametric Analysis on Ultimate Behavior of Cylindrical GFRP Septic Tank (원통형 GFRP 개인하수 처리시설의 극한거동에 대한 매개변수해석)

  • Kim, Sung Bo;Cho, Kwang Je
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1337-1347
    • /
    • 2013
  • The parametric analysis on ultimate behavior of buried cylindrical GFRP(Glass Fiber Reinforced Polymer) septic tank was presented. Two kinds of F.E. analysis model(soil-spring model and 3D full model) was constructed. The ultimate behavior of septic tank was investigated according to the size of stiffened steel ring and properties of underground soil. Ramberg-Osgood model and Druker-Prager model were used for material nonlinear characteristics of GFRP septic tank and soil, respectively. The diameter and thickness of stiffened steel ring inside septic tank, elastic modulus and internal friction angle of soil were selected for parametric variables. The ultimate behavior of septic tank, load-displacement, axial and hoop strain, were calculated and investigated.

Development of equipment for tumor cauterization

  • Hoshino, Hirokazu;Ochiai, Makoto;Sakasegawa, Aya;Hayakawa, Yoshinori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.474-477
    • /
    • 2002
  • Equipment to cauterize tumors by an electrically heated Kanthal wire is under development. The wire( alloy of iron, chromium and Aluminum) keeps sufficient strength up to 1400 degrees in Celsius. Although AC 50Hz current source is used in the prototype experiment, RF current will be used in future. The diameter of the Kanthal wire was 0.3 mm which was connected to Kanthal wire of 0.8 mm. The thicker wire was used as a leading wire. The possibility of application of the heating wire in combination with an ultrasound endoscope was determined, where ultrasound endoscope is to be used to monitor the location on the wire and an extent of a tumor in digestive organs. This procedure requires the wire to be applied inside ultrasound transmitting media. First, the wire was applied in the degassed water in which a chicken liver sample was submerged. The wire, however, burned out in water soon after it became red-hot at 12 A. The reason is that large current is required for the wire to become red-hot due to strong convection. Starch paste of 3 weight percent was employed instead of water. This made the wire red-hot approximately at 6 A, showing the increased viscosity of the starch decreased the convection and the wire was cover by the steam. The liver sample was cauterized successively, while the location of the wire and the liver was monitored by an ultrasound diagnosis equipment outside the plastic vessel of the starch paste.

  • PDF

A Study on the Improvement of the Condensation Heat Transfer Performance of the Helical Grooved and Plain Thermosyphons (나선 그루브와 평관형 열사이폰의 응축열전달 성능 향상에 관한 연구)

  • Han, K.I.;Park, J.U.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.47-53
    • /
    • 2006
  • This study concerns the performance of condensation heat transfer in plain and grooved thermosyphons. Distilled water, methanol, ethanol have been used as the working fluids. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A study was carried out with the characteristics of heat transfer of the thermosyphon 50, 60, 70, 80, 90 helical grooves in which boiling and condensation occur. The liquid filling as the ratio of working fluid volume to total volume of thermosyphon, the kinds of working fluid, the inclination angle, grooves and operating temperature have been used as the experimental parameters. The experimental results show that the number of grooves, the amount of the working fluid, the kind of working fluid, angle of inclination angle are very important factors for the operation of thermosyphon. The maximum heat transfer was obtained when the liquid fill was about 20 to 25 % of the thermosyphon volume. The relatively high rates of heat transfer have been achieved in the thermosyphon with grooves. The helical grooved thermosyphon having 70 to 80 grooves in water, 60 to 70 grooves in methanol and 70 to 80 grooves in ethanol shows the best heat transfer coefficient in both condensation.

  • PDF

Performance Characteristics of a Turbo Blower Having the Various Shapes of a Volute Casing (볼류트 케이싱 형상에 따른 터보블로어 성능특성 고찰)

  • Jang, Choon-Man;Yang, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.9
    • /
    • pp.843-850
    • /
    • 2010
  • This In this paper, we describe the performance characteristics of a turbo blower as a function of the shape of the volute casing: expansion diameter and width of the volute casing. The turbo blower considered in the present study is mainly used in a refuse collection system. The flow characteristics inside the turbo blower were analyzed by a three-dimensional Navier-Stokes solver and compared with experimental results. The distributions of pressure and efficiency obtained by numerical simulation were in good agreement with those determined experimentally. Throughout the numerical simulation of the turbo blower, the blower performance was enhanced by decreasing the local losses in the blade passage and the outlet flow. The efficiency and pressure for the design flow condition were enhanced by about 3% and 2%, respectively, compared to the efficiency and pressure of the reference blower. Detailed flow analysis was performed using the results of the numerical simulation

Study on a Wire Saw Rock Cutting Model for Tunnel Excavation and Cutting Performance Improvement (터널굴착용 와이어쏘 암반절삭 모델 구축 및 절삭성능 향상 연구)

  • Lee, Jin-Ho;Ahn, Sung-Kwon;Lee, Kyoung-Chan;Bang, Choon-Seok;Sagong, Myung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.10
    • /
    • pp.1069-1077
    • /
    • 2015
  • In tunnel excavation using blast, the wire saw rock cutting method generates a discontinuity perimeter around the center cut, and thus prevents blast vibration propagation to reduce vibration and noise. Therefore, the method is expected to be easy to use and economical compared with other methods. In this paper, the cutting mechanism of wire saw in tunnel excavation is investigated. A model describing the changes in cutting depth and wire saw shape inside a rock during cutting is established and validated for this purpose. Through a simulation using the model, the important characteristics of wire saw cut are investigated, and the influences of cutting conditions, such as wire saw tension, wire saw speed, feed speed, depth, and diameter of boring, on cutting performance are also examined. A method to improve the cutting performance is proposed based on the results.

Experimental Study on the Flame Spread Characteristics under Reduced Atmospheric Pressures and Elevated Oxygen Concentrations (저기압 고산소 환경에서 화염 전파특성에 관한 실험적 연구)

  • Yang, Ho-Dong;Kwon, Hang-June;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.78-83
    • /
    • 2016
  • The characteristics of flame spread under similar atmospheric conditions to those inside the first stage of launch vehicles were investigated to provide fundamental knowledge to prevent fires and explosions of vehicles during launching operations. To this end, the rate of flame spread on the solid fuel was measured at elevated oxygen concentrations and reduced atmospheric pressures. A 0.18 mm diameter optical fiber was used as a solid fuel. The experimental results indicated that elevated oxygen concentrations can increase the rate of flame spread while increasing the atmospheric pressures to 1 atm can lead to decreases in the rate of flame spread. The increases in the rate of flame spread with pressure is due mainly to reductions in the convective heat loss that are clarified through an analysis of the pressure dependence on the convective heat transfer coefficient.