• 제목/요약/키워드: Inside diameter

검색결과 742건 처리시간 0.027초

초임계 $CO_2$의 헬리컬 코일관 내 열선단과 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of Supercritical $CO_2$ in a Helically Coiled Tube)

  • 유태근;김대희;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.353-358
    • /
    • 2005
  • The heat transfer and pressure drop of supercritical $CO_2$ cooled in a helically coiled tube was investigated experimentally. The experiments were conducted without oil in the refrigerant loop. The experimental apparatus of the refrigerant loop consist of receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section is a helically coiled tube in tube counter flow heat exchanger with $CO_2$ flowed inside the inner tube and coolant( water) flowed along the outside annular passage, It was made of it copper tube with the inner diameter of 4.55[mm]. the outer diameter of 6.35 [mm] and length of 10000 [mm]. The refrigerant mass fluxes were $200^{\sim}600$ [kg/m2s] and the inlet pressure of gas cooler varied from 7.5 [MPa] to 10.0 [MPa]. The main results are summarized as follows : The heat transfer coefficient of supercritical $CO_2$ increases, as the cooling pressure of gas cooler decreases. And the heat transfer coefficient increases with the increase of the refrigerant mass flux. The pressure drop decreases in increase of the gas cooler pressure and increases with increase the refrigerant mass flux.

  • PDF

오리피스 내부 유동조건에 따른 수직분사제트의 분열특성에 대한 연구 (Effects of Orifice Internal Flow on Transverse Injection into Subsonic Crossflows: Cavitation and Hydraulic Flip)

  • 안규복;김정훈;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.72-75
    • /
    • 2003
  • 본 연구에서는 인젝터 형상에 따른 캐비테이션과 같은 유동 현상이 수직 분사된 액체 제트의 분열에 미치는 영향을 살펴보고자 하였다. 오리피스의 지름과 길이대 지름비(L/d) 및 입구의 형상이 다른 인젝터에서 압력을 변화시켜가며 내부 유동 변화를 살피고 수직분사 시 액주의 분열 거리와 궤적을 구하여 기존의 연구 결과와 비교하고 분석하였다. 실험 결과 곡률이 없는 경우(sharp edged)의 오리피스에서는 어느 정도 이상의 압력에서 모두 캐비테이션이 발생하였고 곡률이 없는 경우 중 길이대 지름비가 작은 오리피스에선 더 높은 압력에서 캐비테이션 성장에 의한 수력튀김(hydraulic flip)현상도 관찰할 수 있었다. 수직분사 시 곡률이 있는 경우와 없는 경우 모두 동일한 모멘텀 플럭스 비(q)에 대해 거의 같은 궤적 형상을 보였으나 캐비테이션이 일어날 경우 교란에 의해 액주의 분열 거리는 감소하였고 수력튀김 또한 제트 단면적의 감소 및 제트의 확산으로 분열거리가 감소하였다.

  • PDF

화학증기침투에 의한 촉매지지체용 C/SiC 복합체 제조에 관한 수치모사 연구 (Studies on the Modeling of the Preparation of the C/SiC Composite for catalyst support by CVI)

  • 이성주;김미현;정귀영
    • Composites Research
    • /
    • 제13권4호
    • /
    • pp.33-41
    • /
    • 2000
  • 본 연구에서는 촉매지지체의 내구성과 내산화성을 향상시키기 위해 활성탄소에 SiC층을 형성하는 것에 관한 수치모사가 수행되었다. 이염화이메틸규소(DDS)로부터 탄화규소를 활성탄소 기공의 내부에 침투 증착시켜 기공성 구조를 유지하면서 활성탄소에 SiC층이 형성된다. 여러 다른 증착 조건에서 모사된 탄화규소의 물성을 연구함으로써 지지체 제조의 최적 증착 조건을 결정하였다. 정상상태하의 등온 반응기 안에서 대류, 확산 및 반응을 모사하여 시간의 경과에 따른 증착량, 기공 반경, 표면적의 변화 등을 구하였다. DDS의 농도가 낮고 반응압력이 작을수록 시료 기공내에 고른 증착이 얻어졌다. 또한 기공내부 증착에서 입자외부 표면 증착으로 바뀌므로 기공직경과 표면적들이 어느 시점에서 변곡점을 갖는 것이 관찰되었다.

  • PDF

Micro Shock Tube에서 발생하는 충격파 실험 (Experimental Study of the Shock Wave Dynamics in Micro Shock Tube)

  • 박진욱;김규완;김희동
    • 한국추진공학회지
    • /
    • 제17권5호
    • /
    • pp.54-59
    • /
    • 2013
  • 현재 Micro Shock Tube는 다양한 공학응용분야에 적용되고 있으며, 특히 우주항공 및 연소기술 그리고 약물전달 등의 분야에서 광범위한 잠재력을 가진 장치 중 하나이다. 그러나 Micro Shock Tube에서의 유동 특성은 작은 직경으로 인해 형성되는 매우 낮은 Reynolds Number와 높은 Knudsen Number의 영향으로 일반적으로 잘 알려진 Macro Shock Tube의 유동 특성과 상이하게 나타난다. 본 연구에서는 이러한 Micro Shock Tube의 유동 특성을 상세히 연구하기 위해 직경이 다른 두 가지 Micro Shock Tube의 실험을 수행하였다. 충격파 전파를 측정하기 위해 고압관의 파막압력 그리고 저압관의 세 지점에 센서를 설치하여 압력을 측정하고 분석하였다. 본 연구로부터, 동일한 파막압력에서 Micro Shock Tube 직경의 증가에 따라 충격파 전파속도가 증가하였고, 반사파의 영향도 더 크게 받았다.

Urea-SCR시스템 액막형 선회분사기의 분사압력변화에 따른 무특성에 관한 연구 (Effect of injection pressure on the atomization characteristics of a liquid sheet-type swirl injector for Urea-SCR system)

  • 김덕진;양동욱;이지근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.510-519
    • /
    • 2013
  • Urea-SCR시스템에 적용하기 위한 액막형 선회분사기의 분사압력변화에 따른 분무특성이 실험적으로 조사되었다. 실험에 사용된 노즐은 형상비 3.1을 갖는 단공 압력식 액막형 선회노즐이며, 노즐선단에 분사되는 유체에 선회류를 형성하기 위한 선회기가 설치되어 있다. 노즐의 분사량 조절은 PWM(pulse width modulation)기법에 의해 제어되었다. 분무의 발달과정은 2차원 PIV에 의해 가시화되었으며, 분무각 변화가 조사되었다. 분무액적의 속도 및 크기는 2차원 PDPA에 의해 상온 대기압 조건에서 측정되었다. 분무구조는 분사압력에 큰 영향을 받으며, SMD는 분사압력 증가에 따라 감소하며 선행연구자의 반실험적 결과와 유사한 경향을 보임을 알 수 있었다.

실린더-슬롯형 그레인을 가진 고체로켓모터의 연소불안정 연구 (A study on combustion instability of solid rocket motor with cylinder-slot grain)

  • 이도형;김홍집
    • 한국음향학회지
    • /
    • 제39권4호
    • /
    • pp.371-377
    • /
    • 2020
  • 종횡비(Length/Diameter, L/D)가 크고, 실린더-슬롯형 그레인을 적용한 고체로켓모터의 연소시험에서 연소불안정 현상이 발생하였다. 압력섭동을 스펙트럼 분석한 결과 중심축 길이방향 주파수가 지배적임이 확인되어, 음향노드와의 일치를 해소하기 위해 실린더 파트의 길이를 증가시켰다. 또한 고체로켓모터에서 발생하는 유동 구조에 의한 불안정성 발생 원인을 분석하기 위하여 음향모드해석과 유동해석을 수행하였다. 설계 변경 전후 그레인 형상을 이용하여 연소실 내 압력 진동 크기 및 주파수에 대해 정량적 비교를 통해 연소불안정이 저감됨을 확인하였다. 최종적으로 연소시험을 수행하여 해석결과와 같이 연소불안정 현상이 사라짐을 확인하였다.

IODINE REMOVAL EFFICIENCY IN NON-SUBMERGED AND SUBMERGED SELF-PRIMING VENTURI SCRUBBER

  • Ali, Majid;Yan, Changqi;Sun, Zhongning;Gu, Haifeng;Wang, Junlong;Khurram, Mehboob
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.203-210
    • /
    • 2013
  • The objective of this conducted research is to study the iodine removal efficiency in a self-priming venturi scrubber for submerged and non-submerged operating conditions experimentally and theoretically. The alkaline solution is used as an absorbent, which is prepared by dissolving sodium hydroxide (NaOH) and sodium thiosulphate ($Na2S_2O_3$) in water to remove the gaseous iodine ($I_2$) from the gas. Iodine removal efficiency is examined at various gas flow rates and inlet concentrations of iodine for submerged and non-submerged operating conditions. In the non-submerged venturi scrubber, only the droplets take part in iodine removal efficiency. However, in a submerged venturi scrubber condition, the iodine gas is absorbed from gas to droplets inside the venturi scrubber and from bubbles to surrounding liquid at the outlet of a venturi scrubber. Experimentally, it is observed that the iodine removal efficiency is greater in the submerged venturi scrubber as compare to a non-submerged venturi scrubber condition. The highest iodine removal efficiency of $0.99{\pm}0.001$ has been achieved in a submerged self-priming venturi scrubber condition. A mathematical correlation is used to predict the theoretical iodine removal efficiency in submerged and non-submerged conditions, and it is compared against the experimental results. The Wilkinson et al. correlation is used to predict the bubble diameter theoretically whereas the Nukiyama and Tanasawa correlation is used for droplet diameter. The mass transfer coefficient for the gas phase is calculated from the Steinberger and Treybal correlation. The calculated results for a submerged venturi scrubber agree well with experimental results but underpredicts in the case of the non-submerged venturi scrubber.

화력발전소의 온배수를 열원으로 이용하는 시설원예 난방용 히트펌프 시스템의 열교환기 설계기준 설정 (Heat Exchanger Design of a Heat Pump System Using the Heated Effluent of Thermal Power Generation Plant as a Heat Source for Greenhouse Heating)

  • 유영선;강연구;장재경;김영화;김종구;강금춘
    • 생물환경조절학회지
    • /
    • 제21권4호
    • /
    • pp.372-378
    • /
    • 2012
  • 본 연구에서는 화력발전소에서 온배수의 형태로 배출되는 폐열을 히트펌프의 열원으로 이용하여 온실의 난방에 활용할 수 있는 히트펌프 시스템을 설계 제작하였으며, 난방 성능을 분석하여 PE 파이프 열교환기의 설계기준을 제시하고자 하였다. PE 파이프 열교환기의 내경은 20mm, 두께는 2mm였으며, Roll의 직경은 1,000mm로 하였다. 연구결과 PE파이프 열교환기의 적정 길이는 1.0RT당 75m로 설계하는 것이 바람직할 것으로 판단되었으며, 이때 히트펌프시스템의 난방성능계수(COPh)는 3.8로 나타났다.

말초신경 결손시 신경도관으로서 Gore-Tex® 도관의 유용성 (The Availability of Gore-Tex® Tube as Nerve Conduit at the Peripheral Nerve Defect)

  • 이기호;오상하;이승렬;강낙헌
    • Archives of Plastic Surgery
    • /
    • 제32권5호
    • /
    • pp.613-618
    • /
    • 2005
  • When a large peripheral nerve defect occurs, an autologous nerve graft is the most ideal method of recinstruction. But an autologous nerve graft has many limitations due to donor site morbidities. Many previous focused on finding the ideal nerve conduit. Among them, $Gore-Tex^{(R)}$ has several advantages over other conduits. It can be manipulated to a suitable size, does not collapse easily, and it is a semi- permeable material that contain pores. A round shaped nerve can be newly formed because of its smooth inner surface. The purpose of this study was to evaluate the availability of $Gore-Tex^{(R)}$ tube as a nerve conduit at the peripheral nerve defect in the rat sciatic nerve. The 10 mm nerve gap was made in each group. A $Gore-Tex^{(R)}$ tube filled with skeletal muscle was inserted and autologous nerve graft was harvested, respectively. In the experimental group, we placed a 0.5 mm thickness, $30{\mu}m$ pored, 1.8 mm in diameter and 14 mm length tube with skeletal muscle inserted inside. In the control group, the nerve gap was inserted with a rat sciatic nerve. We estimated the results electrophysiologically and histologically to 16 weeks postoperatively. Results in the nerve conduction velocity, total myelinated axon count, myelin sheath thickness and mean nerve fiber diameter, the experimental group was substantially lower than that of the control group, but the statistic difference was not significant (p<0.05). The morphology was very similar in both groups, microscopically. From the above results, We conclude that $Gore-Tex^{(R)}$ qualifies as an ideal nerve conduit. It is suggested that $Gore-Tex^{(R)}$ tube filled with skeletal muscle may, substitute for an autologous nerve graft.

수치해석을 통한 샌드드레인과 열주입에 의한 연약지반의 압밀 해석 (Numerical Analysis on Consolidation of Soft Clay by Sand Drain with Heat Injection)

  • 고이 잔나릿;윤찬영
    • 한국지반공학회논문집
    • /
    • 제33권11호
    • /
    • pp.45-57
    • /
    • 2017
  • 연약지반의 압밀거동은 온도변화에 의하여 영향을 받는다. 연약 점토지반 내에 온도가 증가하면 간극수압이 증가하고 간극수압의 소산은 부피와 간극비를 감소시킨다. 또한 높은 온도는 간극유체의 점성을 감소시키므로 압밀속도가 빨라진다. 본 연구에서는 온도가 압밀침하량, 압밀시간, 간극수압과 같은 압밀거동에 미치는 영향을 분석하였으며, 이를 위하여 수리역학적(HM) 및 열수리역학적(THM) 거동에 대한 수치해석을 수행하였다. 열주입과 샌드드레인을 동시에 고려하였으며, 온도 변화 및 샌드드레인 직경 변화를 고려하여 해석을 수행하였다. 해석결과, 시료내부의 온도는 열원의 온도와 샌드드레인의 직경 증가에 따라 증가하는 것으로 나타났다. 또한 열주입은 과잉간극수압을 증가시키고 그에 따라 과압밀 영역에서는 추가적인 침하량을 유발하고 정규압밀 영역에서는 압밀시간을 감소시키는 것으로 나타났다.