• 제목/요약/키워드: Inside diameter

검색결과 742건 처리시간 0.033초

코일형 나선 전열관의 내부 응축열전달 특성에 관한 실험 적 연구 (Experimental Study on In-Tube Condensation Heat Transfer Characteristics of Helically Coiled Spiral Tubes)

  • 박종운;권영철;한규일
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1676-1683
    • /
    • 2001
  • An experimental study on condensation heat transfer characteristics of helically coiled spiral tubes was performed. The refrigerant is R-113. A refrigerant loop was established to measure the condensation heat transfer coefficients. Experiments were carried out uniform heat flux of 15 kw/m$^2$, refrigerant quality of 0.1∼0.9, curvature ratio of 0.016, 0.025 and 0.045. The curvature of a coil was defined as the ratio of the inside diameter of the tube to the diameter of the bending circle. To compare the condensation heat transfer coefficients of coiled spiral tubes, the previous results on coiled plain tubes and straight plain tubes were used. The results shows that the condensation heat transfer coefficients of coiled spiral tubes largely increase, as increasing Re and quality, compared to those of coiled plain tubes and straight plain tubes. As increasing degree of subcooling, however, the condensation heat transfer coefficients on coiled spiral tubes decrease. It is found that the heat transfer enhancement is more better than coiled plain tubes and straight plain tubes, as increasing curvature ratio.

탄화수소계 냉매의 응축 열전달 및 압력강하 특성 (Characteristics of Condensing Heat Transfer and Pressure Drop of HCs Refrigerants)

  • 이호생;이광배;문춘근;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1143-1148
    • /
    • 2005
  • Experimental results for heat transfer characteristic and pressure gradient of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have one tube diameter of 12.70 mm with 0.86 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local condensing heat transfer coefficients of hydrocarbon refrigerants were higher than those of R-22. The average condensing heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than those of R-22 in 12.7 mm and 9.52 mm. This results from the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

  • PDF

나선 그루브형 열사이폰의 작동유체의 변화에 대한 응축열전달 성능에 관한 연구 (A Study on the Performance of Condensation Heat Transfer for Various Working Fluid of Two-Phase Closed Thermosyphons with Various Helical Grooves)

  • 한규일;조동현;박종운;이상진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.239-244
    • /
    • 2003
  • This study concerns the performance of condensing heat transfer in two-phase closed thermosyphons with various helical grooves. Distilled water, methanol, ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The type of working fluid and the numbers of grooves of the thermosyphons with various helical grooves have been used as the experimental parameters. The experimental results have been assessed and compared with existing theories. The results show that the type of working fluids are very important factors for the operation of thermosyphons. And the maximum enhancement (i.e. the ratio of the heat transfer coefficients the helical thermosyphons to plain thermosyphons) is $1.5{\sim}2$ for condensation.

  • PDF

Segmental Wedge를 이용한 차압식 유량측정 방법 (Flowrate Measurement Using Segmental Wedge as a Restriction Device for Differential Pressure)

  • 윤준용;성낙원
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.302-307
    • /
    • 2005
  • The discharge coefficient in segmental wedge having ninety degrees vertex angle for the five kinds of opening ratio with differential pressure taps located at both upstream and downstream of one diameter of pipe was measured main purpose of this work is placed on developing the proper form of an equation for the discharge coefficient of a segmental wedge used as a primary element of flow metering devices, and from thata six-term equation which can express the variability of opening ratios was developed. The same assumption and hypotheses were used and tested for all procedures as conventional differential producers; however, the range of the opening ratio over this work is more expanded than previous studies. The opening ratios of segmental wedge, namely 0.3, 0.4, 0.5, 0.6 and 0.7 were investigated the Reynolds number based on the spool inside diameter ranges from 12,000 to 380,000, the resulting equation for the discharge coefficient is relatively simple; it contains only one variable-opening ratio because the characteristic of discharge coefficient of segmental wedge has little connection with the Reynolds number as shown by previous studies.

  • PDF

Pressure and Flow Distribution in the Inlet Plenum of a Pebble Bed Modular Reactor (PBMR)

  • ;김광용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.244-249
    • /
    • 2005
  • Flow distribution and pressure drop analysis for an inlet plenum of a Pebble Bed Modular Reactor (PBMR) have been performed using Computational Fluid Dynamics. Three-dimensional Navier-Stokes equations have been solved in conjunction with $k-{\epsilon}$ model as a turbulence closure. Non-uniformity in flow distribution is assessed for the reference case and parametric studies have been performed for rising channels diameter, Reynolds number and angle between the inlet ports. Also, two different shapes of the inlet plenum namely, rectangular shape and oval shape, have been analysed. The relative flow mal-distribution parameter shows that the flow distribution in the rising channels for the reference case is strongly non-uniform. As the rising channels diameter decreases, the uniformity in the flow distribution as well as the pressure drop inside the inlet plenum increases. Reynolds number is found to have no effect on the flow distribution in the rising channels for both the shapes of the inlet plenum. The increase in angle between the inlet ports makes the flow distribution in the rising channels more uniform.

  • PDF

미세 입자로 충전된 캐비티에서의 열 기포 형성 (Formation of Thermal Bubble from Particle-Filled Microcavity)

  • 정광훈;이헌주;장영수;이윤표;김호영
    • 대한기계학회논문집B
    • /
    • 제31권3호
    • /
    • pp.248-255
    • /
    • 2007
  • Thermal bubble formation is a fundamental process in nucleate boiling heat transfer and many microelectromechanical thermal systems. One of the established facts is that heterogeneous nucleation is originated from vapors trapped inside cavities. Based on this, we performed an experimental study on the formation of thermal bubbles from microcavity fabricated by microfabrication technology on a copper plate. The cavity was filled with aluminum particles to enhance thermal bubble formation. We observed the thermal bubble behaviors, such as bubble incipience, diameter, frequency and coalescence during nucleate boiling. The experimental data showed that the superheat required to trigger the bubble formation was significantly reduced when the cavity was filled with microparticles. We found that the initial increase of superheat led to the increase of both the departure diameter and frequency while the further increase of superheat caused multiple bubbles to coalesce resulting in the decrease of departure frequency.

X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정 (Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique)

  • 김석;이상준
    • 한국가시화정보학회지
    • /
    • 제4권2호
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF

나선 그루브형 열사이폰의 그루브 수의 변화에 대한 비등열전달 성능에 관한 연구 (A Study on the Performance of Boiling Heat Transfer of Two-Phase Closed Thermosyphons with Various Helical Grooves)

  • 한규일;조동현
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.131-139
    • /
    • 2005
  • This study concerns the performance of boiling heat transfer in two-phase closed thermosyphons with various helical grooves. Distilled water, methanol, ethanol have been used as the working fluids. In the present work, a copper tube of the length of 1200 mm and 14.28 mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550 mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the Performances of having 50, 60, 70, 80 and 50 helical grooves. A Plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for comparison. The type of working fluid and the numbers of grooves of the thermosyphons with various helical grooves have been used as the experimental parameters. The experimental results have been assessed and compared with existing theories. The results show that the number of grooves and the type of working fluids are very important factors for the operation of thermosyphons. The helical grooved thermosyphons having 50 to 60 grooves in water, 60 to 70 grooves in methanol and ethanol shows the best heat boiling heat transfer coefficient.

토사 적체에 따른 우수관의 성능불능확률 (Probability of performance failure of storm sewer according to accumulation of debris)

  • 권혁재
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.509-517
    • /
    • 2010
  • Statistical distribution of annual maximum rainfall intensity of 18 cities in Korea was analyzed and applied to the reliability model which can calculate the probability of performance failure of storm sewer. After the analysis, it was found that distribution of annual maximum rainfall intensity of 18 cities in Korea is well matched with Gumbel distribution. Rational equation was used to estimate the load and Manning's equation was used to estimate the capacity in reliability function to calculate the probability of performance failure of storm sewer. Reliability analysis was performed by developed model applying to the real storm sewer. It was found that probability of performance failure is abruptly increased if the diameter is smaller than certain size. Therefore, cleaning the inside of storm sewer to maintain the original diameter can be one of the best ways to reduce the probability of performance failure. In the present study, probability of performance failure according to accumulation of debris in storm sewer was calculated. It was found that increasing the amount of debris seriously decrease the capacity of storm sewer and significantly increase the probability of performance failure.

나선 그루브형 열사이폰의 작동유체의 변화에 대한 응축열전달 성능에 관한 연구 (A Study on the Performance of Condensation Heat Transfer for Various Working Fluid of Two-Phase Closed Thermosyphons with Various Helical Grooves)

  • 한규일;조동현
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.116-122
    • /
    • 2005
  • This study concerns the performance of condensing heat transfer in two-phase closed thermosyphons with various helical grooves. Distilled water, methanol, ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The type of working fluid and the numbers of grooves of the thermosyphons with various helical grooves have been used as the experimental parameters. The experimental results have been assessed and compared with existing theories. The results show that the type of working fluids are very important factors for the operation of thermosyphons. And the maximum enhancement (i.e. the ratio of the heat transfer coefficients the helical thermosyphons to plain thermosyphons) is $1.5{\sim}2$ for condensation.