• Title/Summary/Keyword: Inserted

Search Result 3,871, Processing Time 0.035 seconds

Exchange Bias Perpendicular Magnetic Anisotropy by Buffer Layer and Inserted Layer in [Pd/Co]5/FeMn Multilayer ([Pd/Co]5/FeMn 막에서의 바닥층과 삽입층에 의한 교환바이어스수직자기이방성)

  • Joo, Ho-Wan;An, Jin-Hee;Lee, Mi-Sun;Kim, Bo-Keun;Choi, Sang-Dea;Lee, Kee-Am
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.5
    • /
    • pp.192-195
    • /
    • 2004
  • Magnetic properties by exchange biased perpendicular magnetic anisotropy in [Pd(0.8 nm)/Co(0.8 nm)]$_{5}$/FeMn(15 nm) multilayers deposited by dc magnetron sputtering system are investigated. As inserted Pd layer of interface between [Pd/Co] multilayer and FeMn film, the Hex of perpendicular anisotropy was improved from 127 Oe to 145 Oe. But result of an experiment by thermal stability, the Hex of the case that an inserted layer was inserted in decreased from low 20$0^{\circ}C$ in about 5$0^{\circ}C$ more if not inserted. If Ta was a buffer layer, the experiment results along material of buffer layer, the H$_{ex}$ obtained the largest 127 Oe. And if Pd was a buffer layer, H$_{ex}$ obtained the largest 169 Oe. Also, the Hc in buffer layer of Ta and Pd obtained the largest 203 Oe and 453 Oe, respectively.

THE EFFECTS OF POROUS REPLAMINEFORM HYDROXYAPATITE AND DECALCIFIED FREEZE DRIED BONE ON THE REGENERATION OF THE ALVEOLAR BONE IN THE PERIODONTALLY INVOLVED EXTRACTION SOCKETS OF DOGS (Porous Replamineform Hydroxyapatite와 Decalcified Freeze Dried Bone이 치주질환 이환 발치와의 치유에 미치는 영향)

  • Son, Hyo-Sang;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.2
    • /
    • pp.315-330
    • /
    • 1993
  • The ultimate goal of periodontal treatment has been to facilitate regeneration of diseased periodontal tissues, destroyed by inflammatory periodontal disease. Various implant materials have been used to restore the alveolar bone defects. Of the various materials, porous replamineform hydroxyapatite (PHA) has good biocompatibility when placed in a bone tissue, and maintains alveolar ridge for a long period. Decalcified freeze dried bone(DFDB) has been widely used in alveolar bone defects because of its conformity and high osteogenic potential. The purpose of this study was to evaluate the effects of PHA and DFDB on the regeneration of the alveolar bone between fresh extraction sockets and periodontally involved extraction sockets. Experimental periodontitis was induced by the ligation of orthodontic elastic threads after surgically creating periodontal defects on the premolars on the right side of 2 adult dogs for 8 weeks. Following the extraction of each tooth, PHA and DFDB were inserted in the extraction sockets. In control group 1, PHA was inserted in the fresh extraction sockets, and in control group 2, DFDB was inserted. In experimental group 1, PHA was inserted in the periodontally involved extraction sockets, and in experimental group 2, DFDB was inserted. After 20 weeks, the specimens were prepared and stained with Hematoxylin-Eosin stain for the light microscopic evaluation. The results of this study were as follows. 1. No inflammation associated with implant materials was evident in any of the groups. 2. DFDB was completely resorbed, PHA was remained in the extraction sockets in the control and experimental groups. 3. In control group 1 and experimental group 1, extraction sockets were not completely filled with new bone. However, original forms of alveolar crests were maintained in control group 2 and experimental group 2. 4. In control group 1 and exprimental group 1, PHA particles surrounded with many giant cells were well tolerated by the fibrous connective tissues in the coronal part of the socket, In the inferior part of the socket, PHA particles were incorporated into the new bone. In both control group 2 and experimental group 2, DFDB was replaced by newly remodeled bone. 5. No differences of degree of new bone formation were evident between control and experimental groups.

  • PDF

A STUDY OF THE CRAZING OF TOOTH STRUCTURE ASSOCIATED WITH PLACEMENT OF PINS (Pin장착시(裝着時)에 치질귀열(齒質龜裂)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Na, Young-Min;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 1985
  • The purpose of this study was to determine the extent of tooth structure crazing when pinhole were drilled in dentin at various distances from the dentionenamel junction, and when pins were inserted by hand wrench and Auto-klutch handpiece. Sixty freshly extracted teeth were embedded in blocks of cold-curing acrylic resin to a level 1mm apical to the cementoenamel junction, the crown of the teeth were removed to a level 1.5mm coronal to the cementoenamel junction. After being sectioned, the cut surface of the teeth were smoothed, and they were divided into 4 groups. Group I : 4 pinholes were drilled with self-threading Minim spiral drill and pins were inserted with hand wrench in fifteen teeth. Group II : 4 pinholes were drilled with self-threading Minim spiral drill and pins were inserted with Auto-klutch handpiece in fifteen teeth. Group III : 4 pinholes were drilled with self-threading Regular spiral drill and pins were inserted with hand wrench in fifteen teeth. Group IV : 4 pinholes were drilled with self-threading Regular spiral drill and pins were inserted with Auto-klutch handpiece in fifteen teeth. The cut surface were then examined microscopically for the presence or absence of craze line. The results were as follows: 1. The self-threading Minim pin groups (Group I & II) produced less craze lines than did the self-threading Regular pin groups (Group III & IV). 2. In the self-threading Minim pin groups, there was more craze lines with hand wrench (Group I) than with Auto-klutch handpiece (Group 11). 3. In the self-threading Regular pin groups, there was more craze lines with hand wrench (Group III) than with Auto-klutch handpiece (Group IV). 4. Placement of the pinhole at 0.0mm from the dentionenamel junction produced more craze lines than placed at 0.5mm, 1.0mm (p<0.05), however there was no statistically significant between the 0.5mm and 1.0mm distance.

  • PDF

The Radiological Findings of the Catheters Inserted 10cm Cephaladly in Epidural Space (경막외강내 두측으로 10cm 삽입한 카테터의 X-선상 소견)

  • Chung, So-Young;Lee, Hyo-Keun;Chae, Jin-Ho;Lee, Chul-Seung;Lee, Chul;Kim, Chan;Kim, Soon-Yul
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.298-303
    • /
    • 1995
  • We have inserted epidural catheter for single or continuous injection of a drug for epidural analgesia. It is important to localize the tip of epidural catheter in appropriate site to acquire the most effective analgesia. In epidural block, we observed course and location of the tip of epidural catheter. Subject: 70 patients were divided into group I(non-injection of saline group during catheter insertion) and group II(injection group during catheter insertion). Group I included cervical(n=20), thoracic(n=10), and lumbar(n=20) epidural group. Group II, cervical(n=10), and lumbar(n=10) epidural group. Method: 19G FlexTip $Plus^{TM}$ Epidural Catheter ($Arrow^{(R)}$) was inserted 10cm cephaladly in epidural space with(group II) or without(group I) saline flushing. We observed course and location of the tip of epidural catheter by C-arm image intensifier during injection of contrast media ($Omnipaque^{(R)}$). Result: In group I, the number of tips of epidural catheters located within 2 cm from inserted site were: cervical 14/20(70%), thoracic 2/10(20%). lumbar 16/20(80%). In thoracic epidural blocks, tips of epidural catheters were more cephaladly located than with cervical and lumbar epidural blocks. With cervical epidural blocks, the number of tips of epidural catheters located within 2 cm from insertion site were less in group II than group I (20% vs. 70%). But no significant differences were noted between group I and group II with lumbar epidural block(90% vs. 80%). The number of tips of epidural catheters located around a predicted site were: cervical 2/20(10%), thoracic 4/10(40%), lumbar 0/20(0%) in group I, and cervical 2/10(20%), lumbar 1/10(10%) in group II. Conclusion: It was impossible to predict the exact location of tips of epidural catheters by measuring the inserted length without epidurogram. With many cases, tips of epidural catheters were located around the insertion site in lumbar epidural blocks, and in some cases around the predicted site in thoracic epidural blocks. The results suggests that epidural block should be done at a point near the required band of analgesia.

  • PDF

The effect of acupuncture using tonification and sedation manipulation at LI4(Hegu) and KI7(Fuliu) on the control of sweating (한조절(汗調節) 혈위(穴位) 합곡(合谷) 복류(復溜)의 보사(補瀉)에 따른 침자(鍼刺)가 지한(止汗)에 미치는 영향(影響))

  • Song, Min-Sun;Choi, Chan-Hun;Youn, Dae-Hwan;Kim, Jee-Hyun;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.25 no.4
    • /
    • pp.133-145
    • /
    • 2008
  • Objectives : The purpose of this study was to exam the effectiveness of acupuncture using the tonification & sedation manipulation for LI4(Hegu) and KI7(Fuliu) which was known to promote sweating for lack sweating and inhibit for excessive sweating. Methods : The subject of this study was 60 people who agreed with participating. The participants were divided into 6 groups as control group without acupuncture, acupuncture group with needle inserted perpendicularly at LI4, KI7 without manipulation(AT-A), acupuncture group with needle inserted and twisted at LI4 using sedation technique and KI7 using tonificaton technique(AT-B), acupuncture group with needle inserted and twisted at LI4 using tonificaton technique and KI7 using sedation technique(AT-C), acupuncture group with needle inserted and twisted at LI4 and KI7 using tonificaton technique(AT-D) and acupuncture group with needle inserted and twisted at LI4 and KI7 using sedation technique(AT-E). We obtained baseline data at a stable condition with the temperature of $25^{\circ}C$. After having the participant stay at $40^{\circ}C$ for 10 minute and treated with acupuncture for 10 minute, we measured the parameters such as sweating rate, water content in subcutaneous, water content in skin surface, systolic blood pressure, diastolic blood pressure, pulse rate, oxygen saturation and body temperature. Results : After the tonification & sedation manipulation at LI4 and KI7, the sweating rate was significantly decreased in AT-B, AT-D and AT-E groups. The water contents in skin surface was significantly decreased in AT-B and AT-E groups. The water contents in subcutaneous was significantly decreased in AT-B, AT-C, AT-D and AT-E groups. However, there were no significant changes in systolic blood pressure, diastolic blood pressure, pulse rate, oxygen saturation and body temperature. Conclusions : Acupuncture at LI4 and KI7 is effective in controling sweating, and the effect varies according to the tonification & sedation manipulation technique.

  • PDF

The Enhancement of Thermal Stability of Nickel Monosilicide by Ir and Co Insertion (Ir과 Co를 첨가한 니켈모노실리사이드의 고온 안정화 연구)

  • Yoon, Ki-Jeong;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1056-1063
    • /
    • 2006
  • Thermal evaporated 10 nm-Ni/l nm-Ir/(or polycrystalline)p-Si(100) and 10 nm-$Ni_{50}Co_{50}$/(or polycrystalline)p-Si(100) films were thermally annealed using rapid thermal annealing fur 40 sec at $300{\sim}1200^{\circ}C$. The annealed bilayer structure developed into Ni(Ir or Co)Si and resulting changes in sheet resistance, microstructure, phase and composition were investigated using a four-point probe, a scanning electron microscopy, a field ion beam, an X-ray diffractometer and an Auger electron spectroscope. The final thickness of Ir- and Co-inserted nickel silicides on single crystal silicon was approximately 20$\sim$40 nm and maintained its sheet resistance below 20 $\Omega$/sq. after the silicidation annealing at $1000^{\circ}C$. The ones on polysilicon had thickness of 20$\sim$55 nm and remained low resistance up to $850^{\circ}C$. A possible reason fur the improved thermal stability of the silicides formed on single crystal silicon substrate is the role of Ir and Co in preventing $NiSi_2$ transformation. Ir and Co also improved thermal stability of silicides formed on polysilicon substrate, but this enhancement was lessened due to the formation of high resistant phases and also a result of silicon mixing during high temperature diffusion. Ir-inserted nickel silicides showed surface roughness below 3 nm, which is appropriate for nano process. In conclusion, the proposed Ir- and Co- inserted nickel silicides may be superior over the conventional nickel monosilicides due to improved thermal stability.

  • PDF

Tenuidraconema koreensis, a New Species of Marine Nematodes (Adenophorea: Desmodorida) from South Korea

  • Rho, Hyun-Soo;Kim, Won
    • Animal cells and systems
    • /
    • v.8 no.3
    • /
    • pp.155-163
    • /
    • 2004
  • Tenuidraconema koreensis, a new species of free-living marine nematodes, collected from the subtidal coarse sediments and various invertebrates of Namae, is described. The new species differs from T. fiersi Decraemer, 1989, the only other species in the genus, by having the combination of the following characters: the position of twelve cephalic adhesion tubes in both sexes (anterior six cephalic adhesion tubes inserted on the rostrum and posterior six inserted on the body annules), and the number of posterior sublateral adhesion tubes (12 in male and 13 in female) and posterior subventral adhesion tubes (15 in male and 19 in female). This paper contains the description of the new species with illustrations and scanning electron microscope (SEM) photomicrographs. This is the first discovery of the monotypic genus Tenuidraconema outside the type locality.

The Properties of Microwave Propagation in Discharging Plasma (방전에 의한 프라즈마에서의 마이크로파 전파특성)

  • Yang, In-Eung;No, Bang-Hyeon;Kim, Bong-Yeol
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.3
    • /
    • pp.31-39
    • /
    • 1968
  • In this paper microwave power propagated through the cold plasma was analyzed and measured with respect to the external magenetic flux density. The d. c discharge plasma was in the rectangular waveguide in which two electrode was inserted, and also the glass diseharge tube inserted in the ractangular wavegside. The direction of microwave pro-pagation, the axis of the discharge tube and external magnetic flux were perpendicular to each other. It showed that the attenuation and absorption of micro wave power propagated in the plasma was increased as the magnetic flux density, the discharge current and the pressure of the gas were increased.

  • PDF

Efficiency evaluation and characteristics of receiver coil under different inserted resonance coils in wireless power charging system for MAGLEV

  • Chung, Yoon Do;Jeon, Haeryong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • As the wireless power transfer (WPT) technology based on strongly resonance coupled method realizes large power charging without any wires through the air, there are advantages compared with the wired counterparts, such as convenient, safety and fearless transmission of power. From this reason, the WPT systems have started to be applied to the wireless charging for various power applications such as train, underwater ship, electric vehicle. This study aims for the effect and characteristics of different inserted resonance coil between Tx and Rx coils for charging system of superconducting magnetic levitation (MAGLEV) train. The transfer efficiency and effect are evaluated with helix type, rectangular type copper resonance coil, and HTS resonance coil under bulb and HTS magnet load, respectively. The input power is adapted with radio frequency (RF) power of 370 kHz below 500 W.