• Title/Summary/Keyword: Inserted

Search Result 3,868, Processing Time 0.03 seconds

Consolidation Characteristics of Dredged Mixed Soil with Inserted Materials (혼입재료에 따른 준설 매립 혼합토의 압밀 특성)

  • Yoon Hyun-Suk;Lee Ki-Ho;Park Jun-Boum;Kim Jae-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.4
    • /
    • pp.13-20
    • /
    • 2005
  • In this study, consolidation test and numerical analysis were performed with the aim of investigating the characteristics of consolidation behavior of mixed soil with the amount and particle shape of inserted materials. Mixed soil was made up of matrix (dredged clay) and inserted material (crashed oyster shell and/or sand). The concept of stress share ratio was introduced to evaluate the consolidation characteristics of mixed soils. And the finite differential numerical analysis was carried out by applying the Mikasa's consolidation theory. From the results of experiments and numerical analysis, it was verified that mixed soil consolidation behavior is affected by changes in inserted material. When a similar amount of granular material was inserted, the compressibility of the clay matrix of oyster shell mixed soil was smaller than that of sand mixed soil.

Analysis of PICC Inserted Patient Data in a Hospital by IV CNS-Driven Intervention (정맥주입 전문간호사가 삽입한 말초삽입형 중심정맥관(PICC) 사용 결과에 대한 후향적 분석)

  • Park, Jeong-Yun;Park, Kwang-Ok;Baek, Mi-Kyung;Kim, Se-Ra;Kwon, Hye-Li;Yang, Su-Ji
    • Journal of Korean Biological Nursing Science
    • /
    • v.6 no.1
    • /
    • pp.33-42
    • /
    • 2004
  • Background : Intravenous(IV) access is becoming an increasingly important part of health care today. The current drive for clinical effectiveness and cost-effective health care serves to increase the need for reliable vascular access. Venous access devices were developed to overcome problems associated with limited peripheral access and frequent venipuncture in patients with long-term therapy. Although the peripherally inserted central catheter(PICC) have become popular during recent years in USA, its procedure is rare in Korea. Purpose : The goal of this study was to analyze the PICC inserted patient data by IV CNS intervention. Method : A Total of 62 PICCs were inserted into 51 patients by the IV CNS during a 10-month period form November, 14, 2002, to October 2, 2002. Data was obtained retrospectively through chart review. Result : The patient population included 34(54.8%) men and 28(45.2%) women, with a mean age 50.6 years. The main indication for PICC placement was to access vein in poor peripheral venous status(40.3%). The mean served interval for PICC insertions was 16.7 days(range, $2{\sim}61$ days). The reasons for removal were completed therapy in 18 cases(29.0%), patient death in 13 cases(21.0%), and mechanical or functional PICC problem in 10cases(16.1%). The three PICCs removed for presumed infection, and one had only positive tip cultures(0.2%). Conclusion : PICCs are rapidly growing popularity and required an extended course of IV therapy.

  • PDF

Flow and Heat Transfer Characteristics of a Multi-Tube Inserted Impinging Jet (노즐출구에 삽입된 다중관에 의한 충돌제트의 유동 및 열전달 특성)

  • Hwang, Sang-Dong;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.135-145
    • /
    • 2004
  • An experimental study is conducted to investigate the flow and heat transfer characteristics of a multi-tube inserted impinging jet. Four different multi-tube devices are tested for various nozzle-to-plate distance. Flow visualization by smoke-wire method and velocity measurements using a hot-wire anemometer are applied to analyze the flow characteristics of the multi-tube insert impinging jet. The local heat transfer coefficients of the multi-tube inserted impinging jet on the impingement surface are measured and the results are compared to those of the conventional jet. In multi-tube inserted system the multi-tube length plays an important role in the flow and heat transfer characteristics of the jet flow. With multi-tube insert of I3d4 and I6d4 which has relatively longer tube length than the multi-tube-exit of I3d1 and I6d1, the flow maintains its increased velocity far downstream due to interaction between adjacent flows. For the small H/D of 4, the local heat transfer coefficients of multi-tube inserted impinging jet are much higher than those of the conventional jet because the flow has higher velocity and turbulent intensity by the use of the multi-tube device. At large gap distance of H/D=12, also higher heat transfer rates are obtained by installing multi-tube insert except multi-tube insert of I3d1.

Identifying the more suitable nostril for nasotracheal intubation using radiographs

  • Chi, Seong In;Park, Sookyung;Joo, Li-Ah;Shin, Teo Jeon;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Background: One nostril must be selected for nasotracheal intubation. In some cases, structural anomalies within the nasal cavity hinder the insertion of the tube or complications, such as epistaxis, develop. This study examined the possibility of using radiography to select the nostril that would induce fewer complications. Methods: Four hundred and five patients who underwent nasotracheal intubation under general anesthesia were studied. A 7.0-mm internal diameter nasal right angle endotracheal (RAE) tube and 6.5-mm internal diameter nasal RAE tube were inserted into men and women, respectively. Complications were considered to have developed in cases in which insertion of the tube into the nasal cavity failed or epistaxis occurred. The tube was inserted into the other nostril for insertion failures and hemostasis was performed in cases of epistaxis. The degree of nasal septal deviation was determined from posteroanterior skull radiographs or panoramic radiographs; the incidence of complications was compared depending on the direction of the septal deviation and the intubated nostril. Results: The radiographs of 390 patients were readable; 94 had nasal septum deviation. The incidence of complications for cases without nasal septum deviation was 16.9%, that for cases in which the tube was inserted into the nostril on the opposite side of the deviation was 18.5%, and that for cases in which the tube was inserted into the nostril with the deviation was 35.0%, showing a high incidence of complications when intubation is performed through the nostril with septum deviation (chi-square test, P < 0.05 ). Conclusions: Although there were no differences in the incidence rates of complications between intubation through the left nostril and that through the right nostril, radiological findings indicated that incidence of complications significantly increased when the tube was inserted into the nostril with the septum deviation.

A Study of Shrinkage Phenomena on Injection modeled Pa Metal Insert (금속 인서트 사출 성형품의 수축 현상에 관한 연구)

  • 김영수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.112-118
    • /
    • 1999
  • Shrinkage behavior was investigated to obtain more accurate dimensions of injected molding parts for free and restricted shrinkage conditions. various parameters for metal inserted injection process, such as thickness of resin, holding pressure and time, mo이 temperature and restriction condition of mold, were considered for the analysis of shrinkage phenomena. For numerical analysis, MOLDFLOW software was used to find the deterministic parameters of filling time, temperature, pressure and holding time. Also , experimental shrinkage effects were measured through actual injection molding process and the resin thickness was under controlled as 3 mm , 5 mm, and 7mm for the shapes of plastic gear made of Polymide(PA) and Polyxymethlene(POM). The main parameters of these injection processes were found to be holding pressure, holding time and mold temperature in the case of metal inserted molding.

  • PDF

Optimal Design for Thrust and Detent Force in Inserted Core Type Slotless PMLSM with Consideration of End Effect (단부효과를 고려한 철심 삽입형 Slotless PMLSM의 추력 및 디텐트력 최적화 설계)

  • 김미용;김규탁
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.525-531
    • /
    • 2004
  • This paper proposes inserted core type of slotless Permanent Magnet Linear Synchronous Motor(PMLSM) to improve its low thrust density. However, by inserting the core between windings of each phase, detent force is generated and it acts as thrust ripple. Furthermore, linear motors generate end effect making thrust ripple. So, this paper applies the neural network to minimize detent force and to maximize thrust. Also, sub-poles is placed at the end parts of the mover to compensate end effect. To confirm of calculation method's validity, the calculated results are compared with experimental results.

Evaluation of strength of waste material mixed concrete using digital image (디지털이미지를 이용한 폐기물 혼합 콘크리트의 강도 평가)

  • Yoon, Hyun-Suk;Lee, Ki-Ho;Park, Jun-Boum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1390-1395
    • /
    • 2005
  • To analyze the effects of oyster shell particles, inserted in the self-hardening matrix such as cement paste, on strength, homogenization analysis using micro structure was used to estimate and assess the apparent elastic modulus of oyster shell particle. DIB modeling technique was used to represent of the micro structure of oyster shell mixed concrete. The results showed that the apparent elastic modulus of LOS (large oyster shell particle) was changed with the amount of LOS inserted. In particular, when the amount of LOS was 200% of the weight of cement, the apparent elastic modulus of LOS tended to decrease rapidly. This could mean that the strength of oyster shell mixed concrete is much affected by LOS inserted material in mixed ratio of 200%.

  • PDF

A Study on the Enhancement of Emission Efficiency of an Organic EL Devices Using the RF Plasma (RF 플라즈마를 이용한 유기 EL소자의 발광 효율에 관한 연구)

  • 박상무;김형권;신백균;임경범;이덕출
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.400-406
    • /
    • 2003
  • Efficient electrodes are devised for organic luminescent device(OLED). ITO electrode is treated with $O_2$ plasma. In order to inject hole efficiently, there is proposed the shape of anode that inserted plasma polymerized films as buffer layer between anode and organic layer using thiophene monomer. In the case of device inserted the buffer layer by using the plasma polymerization after $O_2$ plasma processing for ITO transparent electrode, since it forms the stable interface and reduce the moving speed of hole, the recombination of hole and electronic are made in the emitting layer. Therefore it realized the device capability of two times in the aspect of luminous efficiency than the device which do not be inserted the buffer layer. Experiments are limited to the device that has the structure of TPD/$AIq_3$, however, the aforementioned electrodes can similarly applied to the organic luminous device and the Polymer luminous device.

DWT based Digital Image Watermarking using Labview Machine Vision (DWT기반 Labview Machine Vision을 이용한 디지털 이미지 워터마킹)

  • Kim, Hyoung-Gwon;Song, Yun-Jae;Ahn, Tae-Chon
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.198-200
    • /
    • 2005
  • Recently, intellectual property problem caused by illegal copy or circulation of digital contents with computer and advance of network. it will lose producer's desire and cause economic losses. so we need to demand ownership protection technology for prevent illegal copy without an owner consent and protect ownership with effect. in this paper, we change digital image at frequency domain and choose a factor choosing frequency area with human perceptibility. we inserted repetitive and adaptive watermark on the whole image by Labview Machine Vision. watermark inserted into the high frequency concentrated textual area with Wavelet Transform and then reduced damage of image by human visual feature after inserted watermark

  • PDF

Four Cases of Foreign Body in Lower Urinary Tract (하부 요로계 이물 : 4례 증례보고)

  • Yoo, Jin-Wook;Moon, Ki-Hak;Jung, Hee-Chang;Park, Tong-Choon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.391-396
    • /
    • 1998
  • Foreign bodies in genitourinary tract are common and almost of them are within the bladder. These foreign bodies were inserted or applied for autoerotic, psychiatric, therapeutic, or no definite reasons by the patient. Foreign bodies(a thermometer and a piece of cloth) in the bladder were inserted as a mean of masturbation in two cases, and a cooper wire in the posterior urethra was introduced by iatrogenic causes in one case. In one case, four magnets were inserted into the bladder for the purpose of forceful penile erection. Clinical history, symptom, radiologic study, and endoscopic examination were required to diagnose foreign body. They were easily removed by endoscopic manipulation or open surgical procedure.

  • PDF