• 제목/요약/키워드: Inserted

검색결과 3,868건 처리시간 0.03초

HAMILTONIAN INSERTED GRAPHS AND SQUARES

  • Pramanik, L.K.;Adhikari, M.R.
    • 충청수학회지
    • /
    • 제19권1호
    • /
    • pp.37-47
    • /
    • 2006
  • In this paper we characterize the graphs whose inserted graphs are Hamiltonian, and we study the relationship between Hamiltonian graphs and inserted graphs. Also we prove that if a connected graph G contains at least 3 vertices then inserted graph of the square of G is Hamiltonian and if G contains at least 3 edges then the square of inserted graph of G is Hamiltonian.

  • PDF

Effects of Heat Treatment and Rest-inserted Exercise on Muscle Activity

  • Bang Jae-Kyun;Hwang Sung-Jae;Kim Chi-Hyun
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권2호
    • /
    • pp.73-77
    • /
    • 2006
  • Prolonged immobilization leads to significant weakness and atrophy of the skeletal muscle and can also impair the recovery of muscle strength following injury. Therefore, it is important to minimize the period under immobilization and accelerate the return to normal activity. This study examined the effects of combined heat treatment and rest-inserted exercise on the muscle activity of the lower limb during knee flexion/extension. Twelve healthy subjects were assigned to 4 groups that included: (1) heat treatment + rest-inserted exercise; (2) heat treatment + continuous exercise; (3) no heat treatment + rest-inserted exercise; and (4) no heat treatment + continuous exercise. Heat treatment was applied for 15 mins prior to exercise. Continuous exercise groups performed knee flexion/extension at 0.5 Hz for 300 cycles without rest whereas rest-inserted exercise groups performed the same exercise but with 2 mins rest inserted every 60 cycles of continuous exercise. Changes in the rectus femoris and hamstring muscle activities were assessed at 0 and 2 weeks of treatment by measuring the electromyography signals of isokinetic maximum voluntary contraction. Significant increases in both the rectus femoris and hamstring muscles were observed after only 2 weeks of treatment when both heat treatment and rest-inserted exercise were performed. These results suggest that combination of various treatment techniques, such as heat treatment and rest-inserted exercise, may accelerate the recovery of muscle strength following injury or immobilization.

자동차부품용 알루미늄인서트 사출성형공정 구현에 관한 연구 (A Study on Implementation of Al-Inserted Plastic Injection Molding Process for Automobile Interior-Parts)

  • 노태정;김경수
    • 한국정밀공학회지
    • /
    • 제25권5호
    • /
    • pp.43-51
    • /
    • 2008
  • Generally a plastic injection molding is a manufacturing process used to produce the various parts of complicated shape at low cost. The objective of this study is to implement a new plastic injection molding process with inserted Aluminum sheet, which is highly durable, light and luminous. Moldflow analysis and simulation of plastic injection molding process with inserted Aluminum sheet were carried out in order to predict optimal molding operation conditions. The experimental results in the Al-inserted plastic injection molding process were compared with the simulation results by Moldflow. Durability and reliability test results for trial products were satisfied to adopt the Al-inserted plastic injection molding process developed as manufacturing of automobile interior parts.

보아탕(補兒湯)이 림프구의 증식능(增殖能)에 미치는 영향(影響) (The effect of Boa-tang to the lymphocytes)

  • 임재국;홍무창;하윤문
    • 동의생리학회지
    • /
    • 제14권2호통권20호
    • /
    • pp.83-97
    • /
    • 1999
  • By inserting Boa-tang into culture median of lymphocytes from spleen of rat and lymphocytes in human peripheral blood The results were as follow. 1. In case of spleen lymphocytes of rat, cultures of lymphocytes did not significantly increased which were inserted Boa-tang $100{\mu}g/ml$, and which were inserted $10{\mu}g/ml$ at 3rd day 2. In case of spleen lymphocytes of rat, cultures of lymphocytes were significantly increased which were inserted Boa-tang $10{\mu}g/ml$ with Con A $2.5{\mu}g/ml$ at 2nd, 3rd day, and Boa-tang $1{\mu}g/ml$ with ConA $2.5{\mu}g/ml$ at 3rd day than inserted ConA $2.5{\mu}g/ml$ 3. In case of lymphocytes in human peripheral blood, cultures of lymphocytes were significantly increased which were inserted Boa-tang $100{\mu}g/ml$ and $10{\mu}g/ml$ at 2nd day to 5st day, and which were inserted Boa-tang $1000{\mu}g/ml$ at 2nd day to 5th day, and which were inserted $1{\mu}g/ml$ at 2nd day By looking at the following results, in case of rat cultures of lymphocytes were significantly increased which were inserted the lower density, but in case of human cultures of lymphocytes were significantly increased which were inserted the higher density.

  • PDF

연면방전에 미치는 도전층의 영향에 관한 연구 (A study on the effects of a conducting metallic barrier on the surface creepage flash over discharge)

  • 정성계
    • 전기의세계
    • /
    • 제17권3호
    • /
    • pp.7-28
    • /
    • 1968
  • When a insulator plate is inserted to the discharge path of a space discharge gap in which the field strength is not uniform, the spark voltage under the atmospheric pressure between the electrodes decreases or rises according to the position of the insulating plate. Also it is reported that if a metallic barrier plate is inserted to the discharge path of the same space discharge gap, similar variations of spark voltage are found. Speaking briefly, mensioned above are the spark voltage characteristics when an insulator or metallic barrier is inserted to the space discharge gap. Also some experimental results, concerning to the surface creepage flash over characteristics at the case when an insulator barrier is inserted to the discharge path of a surface creepage discharge gap, were reported by Peek. But up to now there are no reports on surface flash over voltage characteristics at the case when a metallic barrier is inserted to the surface creepage gap. In this study the effects of a conducting metallic barrier inserted to the path of a surface creepage discharge gap on the flash over voltage characteristics are investigated theoretically and experimentally, and got some important results, clearing the effects of the position and width of a conducting barrier is inserted, the surface flash over voltage characteristics appear as an Inverse N or W Characteristics. Such theoretical or experimental results may have some relation not only with the effects of dry belt and snow on suspension insulators, but also with the effects of dirty zone or water drops on the surface creepage flash over voltage.

  • PDF

THE CONNECTIVITY OF INSERTED GRAPHS

  • Adhikari, M.R.;Pramanik, L.K.
    • 충청수학회지
    • /
    • 제18권1호
    • /
    • pp.73-80
    • /
    • 2005
  • The aim of the paper is to study the connectivity and the edge-connectivity of inserted graph I(G) of a graph G with the help of connectivity and the edge-connectivity of that graph G.

  • PDF

폴리비닐알코올 하이드로겔 캅셀을 삽입한 중공좌제로부터 염산프로프라놀롤의 조절 방출 (Controlled Release of Propranolol.HCI from Hollow Type Suppositories Inserted Polyvinyl Alcohol Hydrogel Capsule)

  • 진선경;문이렌;구영순
    • 약학회지
    • /
    • 제43권2호
    • /
    • pp.150-159
    • /
    • 1999
  • Hollow type suppositories inserted polyvinyl alcohol (PVA) hydrogel capsule containing propranolol·HCI (PPH) were prepared using different bases, polyethylene glycol (PEG), Witepsol H-15 (WH-15) and Witepsol W-35 (WW-35) to improve the controlled release of PPH. The release of PPH from the hollow type suppository inserted PVA hydrogel capsule was retarded than that from PEG, WH-15, or WW-35 hollow type suppositories in rat rectal cavity. When the suppositories were administered to rats, the controlled release of PPH was proved by the plasma concentration-time-profiles of PPH. No significant difference (p〈0.05) among the three different hollow type suppositories was observed in terms of AUC and MRT of PPH. WH-15 hollow type suppository inserted 12% of PVA hydrogel capsule caused irritation to rat rectal mucosa. However, the WH-15 hollow type suppository inserted PVA hydrogel capsule caused no severe irritation on rectal mucosa. The application of the hollow type suppositories using PVA in sustained rectal delivery of drugs might be feasible.

  • PDF

공기조화기내 메쉬삽입 물-공기 직접접촉의 열전달 특성 연구 (Air handling unit utilizing water/air direct contact heat exchanger with mesh)

  • 전용한;문명훈;김종윤;김남진;서태범;김종보
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1161-1166
    • /
    • 2008
  • The objective of this research was to investigate the enhancement of heat transfer by mesh in water/air direct contact air conditioning system. Mesh is inserted as a turbulent promoter in front of the water injection nozzle. The heat transfer characteristics with and without mesh and the effect of the number of inserted mesh and mesh porosity size have been studied experimentally. Inserted mesh improves heat transfer efficiency compared to non-inserted mesh system and heat transfer efficiency increased as the number of mesh is increased. Meanwhile, heat transfer efficiency decreased as the porosity of the mesh is increased. With inserted mesh, inlet and outlet temperature difference of air increased more than 50%. Heat exchange time of water/air to reach the 100% humidity decreased less than 30%. This result shows inserted mesh can enhance the performance of the water/air direct contact air conditioning system.

  • PDF

공기조화기내 메쉬삽입 물-공기 직접접촉의 열전달 특성 연구 (Air Handling Unit Utilizing Water/Air Direct Contact Heat Exchanger with Mesh)

  • 전용한;김종윤;김남진;서태범;김종보
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.75-80
    • /
    • 2008
  • The objective of this research was to investigate the enhancement of heat transfer by mesh in water/air direct contact air conditioning system. Mesh is inserted as a turbulent promoter in front of the water injection nozzle. The heat transfer characteristics with and without mesh and the effect of the number of inserted mesh and mesh porosity size have been studied experimentally. Inserted mesh improves heat transfer efficiency compared to non~inserted mesh system and heat transfer efficiency increased as the number of mesh is increased. Meanwhile, heat transfer efficiency decreased as the porosity of the mesh is increased. With inserted mesh, inlet and outlet temperature difference of air increased more than 50%. Heat exchange time of water/air to reach the 100% humidity decreased less than 30%. This result shows inserted mesh can enhance the performance of the water/air direct contact air conditioning system.

이리듐이 첨가된 니켈실리사이드의 적외선 흡수 특성 (IR Absorption Property in Nano-thick Ir-inserted Nickel Silicides)

  • 윤기정;송오성;한정조
    • 대한금속재료학회지
    • /
    • 제46권11호
    • /
    • pp.755-761
    • /
    • 2008
  • We fabricated thermally evaporated 10 nm-Ni/1 nm-Ir/(poly)Si films to investigate the energy saving property of silicides formed by rapid thermal annealing (RTA) at the temperature range of $300{\sim}1200^{\circ}C$ for 40 seconds. Moreover, we fabricated 100 nm-thick ITO/(poly)Si films with an rf-sputter as references. A transmission electron microscope (TEM) and an X-ray diffractometer were used to determine cross-sectional microstructure and phase changes. A UV-VIS-NIR and FT-IR (Fourier transform infrared spectroscopy) were employed for near-IR and middle-IR absorbance. Through TEM analysis, we confirmed 20~65 nm-thick silicide layers formed on the single and polycrystalline silicon substrates. Ir-inserted nickel silicide on single crystalline substrate showed almost the same absorbance in near IR region as well as ITO, but Ir-inserted nickel silicide on polycrystalline substrate, which had the uniform absorbance in specific region, showed better absorbance in near IR region than ITO. The Ir-inserted nickel silicide on polycrystalline substrate particularly showed better absorbance in middle IR region than ITO. The results imply that nano-thick Ir-inserted nickel silicides may have excellent absorbing capacity in near-IR and middle-IR region.