• Title/Summary/Keyword: Input Faults

Search Result 174, Processing Time 0.028 seconds

Trend Monitoring of A Turbofan Engine for Long Endurance UAV Using Fuzzy Logic

  • Kong, Chang-Duk;Ki, Ja-Young;Oh, Seong-Hwan;Kim, Ji-Hyun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.64-70
    • /
    • 2008
  • The UAV propulsion system that will be operated for long time at more than 40,000ft altitude should have not only fuel flow minimization but also high reliability and durability. If this UAV propulsion system may have faults, it is not easy to recover the system from the abnormal, and hence an accurate diagnostic technology must be needed to keep the operational reliability. For this purpose, the development of the health monitoring system which can monitor remotely the engine condition should be required. In this study, a fuzzy trend monitoring method for detecting the engine faults including mechanical faults was proposed through analyzing performance trends of measurement data. The trend monitoring is an engine conditioning method which can find engine faults by monitoring important measuring parameters such as fuel flow, exhaust gas temperatures, rotational speeds, vibration and etc. Using engine condition database as an input to be generated by linear regression analysis of real engine instrument data, an application of the fuzzy logic in diagnostics estimated the cause of fault in each component. According to study results. it was confirmed that the proposed trend monitoring method can improve reliability and durability of the propulsion system for a long endurance UAV to be operated at medium altitude.

The Fault Detection of an Air-Conditioning System by Using a Residual Input RBF Neural Network (잔차입력 RBF 신경망을 사용한 냉방기 고장검출 알고리즘)

  • Han, Do-Young;Ryoo, Byoung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.780-788
    • /
    • 2005
  • Two different types of algorithms were developed and applied to detect the partial faults of a multi-type air conditioning system. Partial faults include the compressor valve leakage, the refrigerant pipe partial blockage, the condenser fouling, and the evaporator fouling. The first algorithm was developed by using mathematical models and parity relations, and the second algorithm was developed by using mathematical models and a RBF neural network. Test results showed that the second algorithm was better than the first algorithm in detecting various partial faults of the system. Therefore, the algorithm developed by using mathematical models and a RBF neural network may be used for the detection of partial faults of an air-conditioning system.

Synthesis for Testability of Synchronous Sequential Circuits Using Undefined States on Incompletely-Specified State Transition Graph (불완전명세 상태천이그래프상에서 미정의상태를 이용한 동기순차회로의 테스트용이화 합성)

  • Choi, Ho-Yong;Kim, Soo-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.10 s.340
    • /
    • pp.47-54
    • /
    • 2005
  • In this paper, a new synthesis method for testability of synchronous sequential circuits is suggested on an incompletely-specified state transition graph (STG) by reducing the number of redundant faults. In the suggested synthesis method, 1) a given STG is modified by adding undefined states and unspecified input transitions using distinguishable transition, 2) the STG is modified to be strongly-connected as much as possible. Experimental results with MCNC benchmark show that the number of redundant faults of gate-level circuits synthesized by our modified STGs are reduced, and much higher fault coverage is obtained.

A Study on Trend Monitoring of a Long Endurance UAV s Gas Turbine to be Operated at Medium High Altitude

  • Kho, Seong-Hee;Ki, Ja-Young;Kong, Chang-Duk;Oh, Seong-Hwan;Kim, Ji-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.84-88
    • /
    • 2008
  • The UAV propulsion system that will be operated for long time at more than 40,000ft altitude should have not only fuel flow minimization but also high reliability and durability. If this UAV propulsion system may have faults, it is not easy to recover the system from the abnormal, and hence an accurate diagnostic technology must be needed to keep the operational reliability. For this purpose, the development of the health monitoring system which can monitor remotely the engine condition should be required. In this study, a fuzzy trend monitoring method for detecting the engine faults including mechanical faults was proposed through analyzing performance trends of measurement data. The trend monitoring is an engine conditioning method which can find engine faults by monitoring important measuring parameters such as fuel flow, exhaust gas temperatures, rotational speeds, vibration and etc. Using engine condition database as an input to be generated by linear regression analysis of real engine instrument data, an application of the fuzzy logic in diagnostics estimated the cause of fault in each component. According to study results, it was confirmed that the proposed trend monitoring method can improve reliability and durability of the propulsion system for a long endurance UAV to be operated at medium altitude.

  • PDF

Fault Detection of a Spacecraft's Reaction Wheels by Extended Unknown Input Observer (확장형 미지입력 관측기를 이용한 위성 반작용 휠의 고장 검출)

  • Jin, Jae-Hyun;Yong, Ki-Ryeok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.11
    • /
    • pp.1138-1144
    • /
    • 2011
  • This article deals with the problem of fault detection of a spacecraft's actuators. The authors introduce an extended unknown input observer for nonlinear systems. This is an extended form of unknown input observers which are used for linear systems. Since faults are not available, those are considered as unknown inputs. Unknown input observers can estimate states without full information of inputs if some conditions are satisfied. The authors suggest a continuous-time extended UIO (eUIO) and prove the convergence of state estimation errors. Since the dynamic equation of a spacecraft is nonlinear, an extended UIO can be applied. Three eUIOs are designed to monitor three reaction wheels. The moving averages of each eUIO's residuals are selected for decision logic. The proposed method is verified by numerical simulations.

Fault Detection in Linear Descriptor Systems Via Unknown Input PI Observer

  • Hwan Seong kim;Yeu, Tae-Kyeong;Shigeyasy Kawaji
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.2
    • /
    • pp.77-82
    • /
    • 2001
  • This paper deals with a fault detection algorithm for linear descriptor systems via unknown input PI observer. An unknown input PI observer is presented and its realization conditions is proposed by using the rank condition of system matrices. From the characteristics of unknown input PI observer, the states of system with unknown inputs are estimated and the occurrences of fault are detected, and its magnitudes are estimated easily by using integrated output estimation error under the step faults. Finally, a numerical example is given to verify the effectiveness of the proposed fault detection algorithm.

  • PDF

A Study on Fault Diagnosis of Boiler Tube Leakage based on Neural Network using Data Mining Technique in the Thermal Power Plant (데이터마이닝 기법을 이용한 신경망 기반의 화력발전소 보일러 튜브 누설 고장 진단에 관한 연구)

  • Kim, Kyu-Han;Lee, Heung-Seok;Jeong, Hee-Myung;Kim, Hyung-Su;Park, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1445-1453
    • /
    • 2017
  • In this paper, we propose a fault detection model based on multi-layer neural network using data mining technique for faults due to boiler tube leakage in a thermal power plant. Major measurement data related to faults are analyzed using statistical methods. Based on the analysis results, the number of input data of the proposed fault detection model is simplified. Then, each input data is clustering with normal data and fault data by applying K-Means algorithm, which is one of the data mining techniques. fault data were trained by the neural network and tested fault detection for boiler tube leakage fault.

Multiple Fault Detection in Combinational Logic Networks (조합논리회로의 다중결함검출)

  • 고경식;김흥수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.4
    • /
    • pp.21-27
    • /
    • 1975
  • In this paper, a procedure for deriving of multiple fault detection test sets is presented for fan-out reconvergent combinational logic networks. A fan-out network is decomposed into a set of fan-out free subnetworks by breaking the internal fan-out points, and the minimal detecting test sets for each subnetwork are found separately. And then, the compatible tests amonng each test set are combined maximally into composite tests to generate primary input binary vectors. The technique for generating minimal test experiments which cover all the possible faults is illustrated in detail by examples.

  • PDF

Development of Fault Detection Method for a Transformer Using Neural Network (신경회로망을 이용한 변압기 사고 검출 기법 개발)

  • 김일남;김남호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.43-50
    • /
    • 2003
  • This presents a fault detecting method for a power transformer based upon a neural network. To maintain a normal relay operating conditions, external winding faults of a power transformer and magnetic inrush have been tested under consideration of the EMTP/ATP software and internal faults of power transformer have been tested by the EMTP/BCTRAN software. The neural network has been evaluated by the proposed fault. Input variables of the neural network for the proposed model can be obtained from fundamental currents, restraining and operating currents. This algorithm uses back-propagation and the ratio of a restraining current and an operating current as relay input parameters. The ratio may enhance the fault detection since the restraining currents increase rapidly at external faults. The proposed detecting method has been applied to the practical relay systems for transformer protection. As a result, the proposed detecting method based on the neural network has been shown to have better characteristics.

Diagnosis of Induction Motor Faults Using Inverter Input Current Analysis (인버터 입력전류 분석을 이용한 유도전동기 고장진단)

  • Han, Jungho;Song, Joong-Ho;Choi, Kyu-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.492-498
    • /
    • 2016
  • It is well known that since abrupt faults in induction motors tend to lead to subsequent faults and deterioration of the drive apparatus, motor faults may lead to several operating restrictions, such as security problems and economic loss. A lot of research has been done in the area of diagnosis to detect machine faults and to prevent catastrophic hazards in the motor drive system. This paper presents a new method of motor current signature analysis in which the DC-link current of the inverter-driven induction motor system, where a single current sensor is employed instead of three AC current sensors, is measured, and fast Fourier transform analysis is performed. This proposed method makes it possible to easily discern and clearly separate the motor fault current signature from the normal operation current flowing through the stator and rotor windings.