The Effect of Inorganic Material in Polymer Electrolyte for Lithium Secondary Battery (리튬이차전지용 고분전해질의 무기물의 첨가에 대한 영향)

  • Park, Soo-Gil;Park, Jong-Eun;Lee, Hong-Ki;Lee, Ju-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.822-824
    • /
    • 1998
  • The lithium polymer battery with polymer electrolyte is expected as a safe and long cycle life battery. This paper reports primarily the recent development results of a solid polymer electrolyte, which is a key point of the secondary battery system. The new type of polymer electrolyte was prepared under a dry Ar atmosphere by dissolving $LiCIO_4$ in a matrix of EC, PC and then dispersing polyacrylonitrile(PAN). Also adding some inorganic filler $Al_2O_3$. The dispersed solution heated at $120^{\circ}C$. The polymer electrolyte were characterized by EIS(Electrochemical Impedance Spectroscopy), TGA(Thermo Gravimetric analysis), DMA(Dynamic Mechanical Analyzer), DSC (Differential Scanning Calorimetry). The lithium ion yield is 0.29 when PAN-$Al_2O_3$ which was applied DC 5mV. The ionic conductivity of PAN, PAN-$Al_2O_3$ polymer electrolytes were showed $1.0{\times}10^{-4}S/cm$, $8.4{\times}10^{-4}S/cm$ at room temperature. When inorganic filler was added in the polymer electrolyte, ionic conductivity and lithium yield more larger than without inorganic filler.

  • PDF

Performance of a Ceramic Fiber Reinforced Polymer Membrane as Electrolyte in Direct Methanol Fuel Cell

  • Nair, Balagopal N.;Yoshikawa, Daishi;Taguchi, Hisatomi
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.53-56
    • /
    • 2004
  • Direct Methanol Fuel Cell (DMFC) is considered as a candidate technology for applications in stationary, transportation as well as electronic power generation purposes. To develop a high performance direct methanol fuel cell(DMFC), a competent electrolyte membrane is needed. The electrolyte membrane should be durable and methanol crossover must be low. One of the approaches to increase the stability of generally used polymer electrolyte membranes such as Nafion against swelling or thermal degradation is to bond it with an inorganic material physically or chemically. In Noritake Company, we have developed a novel method of reinforcing the polymer electrolyte matrix with inorganic fibers. Methanol crossover values measured were significantly lower than the original polymer electrolyte membranes. These fiber reinforced electrolyte membranes (FREM) were used for DMFC study and stable power output values as high 160 mW/$\textrm{cm}^2$ were measured. The details of the characteristics of the membranes as well as I-V data of fuel cell stacks are detailed in the paper.

A Study on the Organic/inorganic Composite Electrolyte Membranes for Dye Sensitized Solar Cell (염료감응형 태양전지를 위한 유기/무기 복합 전해질막에 대한 연구)

  • Koo, Ja-Kyung;Choi, Mi-Jung;Shin, Chun-Hwa;Kang, Tae-Un;Cho, Nam-Jun
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.345-353
    • /
    • 2008
  • Organic/inorganic composite electrolyte membranes were prepared for dye sensitized solar cell (DSSC). Polyethylene Glycol (PEG)s with various molecular weight (400, 600, 1,500 and 3,400) was ethoxysilated to fabricate organic/inorganic composite materials through sol-gel processes. The electrolyte membranes were produced by doping the composite materials with NaI and $I_2$, and their ionic conducting behavior was investigated. The ionic conductivity of the composite electrolyte was highly affected by the PEG molecular weight, and the highest conductivity was shown by the composite membrane prepared with PEG with the molecular weight of 1,500. The composite electrolyte membranes showed considerable improvement of ionic conductivity. Compared to PEO electrolyte membranes, the composite electrolyte membrane prepared by PEG, MW 1,500, showed much higher ionic conductivity.

Preparation and Characterization of Advanced Organic Polymer - Inorganic Composite Gel Electrolyte for Dye-sensitized Solar Cells (염료 감응 태양전지를 위한 고급 유기 고분자 - 무기 복합 겔형 전해질의 제조와 특성분석)

  • Akhtar, M. Shaheer;Park, Jung-Guen;Kim, Ui-Yeon;Lee, Hyun-Choel;Yang, O-Bong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.350-354
    • /
    • 2009
  • In this work, polymer - inorganic composites have prepared using polymer such as polyethylene glycol (PEG)/poly (methyl methacrylate, PMMA) and inorganic nanofillers materials such as TiO2 nanotubes (TiNTs)/carbon nanotubes (CNTs). The extensive structural, morphological and ionic properties revealed that the high surface area and tubular feature of nanofillers improved the interaction and cross-linking to polymer matrix which is significantly enhanced the ionic conductivity and electrical properties of composite electrolytes. Comparably high conversion efficiency ~4.5% has been observed by using the newly prepared PEG-TiNTs composite solid electrolyte as compared with PMMA-CNTs electrolyte based DSSCs (~3%). The detailed comparative properties would be discussed in term of their structural, morphology, ionic and photovoltaic properties.

  • PDF

Effect of Inorganic Coagulants on the Performance of Electro-Chemical Treatment Process Treating Hospital Wastewater (병원폐수의 전기화학적 처리시 무기응집제 주입 효과에 관한 연구)

  • Jeong, Seung-Hyun;Jeong, Byung-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.709-716
    • /
    • 2011
  • Effect of inorganic coagulants dosing on the performance of electro-chemical process was studied when treating hospital wastewater having low electrolyte concentration. It is thought that adding inorganic coagulants caused increase in concentration of electrolyte and this caused increase in free chloride concentration and consequently, caused increase in indirect oxidation effect. Thus, COD removal efficiencies more than doubled in percentage terms at the 2 hrs of reaction time and current density of $1.76A/dm^2$ compared with the results obtained from the parallel experiments without adding inorganic coagulants. T-N removal efficiencies approximately doubled in percentage terms at the 2 hrs of reaction time and 700 ppm of coagulants addition and applied current density of $1.76A/dm^2$ due to the increase of free residual chlorine such as HOCl caused by increase of electrolyte concentration through the addition of inorganic coagulants. Under the same experimental condition, more than 90% of T-P removal efficiencies was obtained. The reason can be explained that increase of chemical adsorption rate between phosphate and insoluble metal compounds caused by dissolved oxygen generated from anode by the increased electrolyte concentration through inorganic coagulants addition make a major role in improving T-P removal efficiencies. It can be concluded that inorganic coagulants addition as the supplemental agent of electrolyte is effective way in improving organic and nutrient salt removal efficiency when treating hospital wastewater having low electrolyte concentration.

Organic / inorganic composite membrane for Polymer Electrolyte Membrane Fuel Cell (고분자전해질 연료전지용 유기/무기 복합 전해질)

  • Choi Seong Ho;Hong Hyeon Sil;Lee Heung Chan;Kim Yu Mi;Kim Geon
    • 한국전기화학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.169-171
    • /
    • 2003
  • Organic/inorganic hybrid membranes have been prepared and evaluated as polymer electrolytes in a polymer electrolyte membrane fuel cell (PEMFC). Previously, partially fluorinated poly (arylenether) was synthesized and the polymer was sulfonated by fuming sulfuric acid$(30\%\;SO_3)$. Modification of these polymers with coupling agent and inorganic materials was carried out to prepare membranes. Membranes cast from these materials were investigated in relation to the proton conductivity and weight loss at the room temperature. It was found that these membranes had a higher conductivity of $10^{-2}\;Scm^{-1}$ at the room temperature. But inorganic materials have leaked out from the hybrid membrane. If this problem is resolved, organic/inorganic hybrid membranes will become satisfactory Polymer electrolytes for the PEMFC.

  • PDF

Synthesis of Inorganic-Organic Composite Electrolyte Membranes for DMFCs (DMFC용 무기-유기 복합 전해질 막의 합성)

  • Kim, Eun-Hyung;Yoon, Gug-Ho;Park, Sung-Bum;Oh, Myung-Hoon;Kim, Sung-Jin;Park, Yong-Il
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.2
    • /
    • pp.119-125
    • /
    • 2008
  • The FAS(Fluoroalkylsilane)/Nafion inorganic-organic composite electrolyte membrane was successfully fabricated through sol-gel method. The FAS having hydrophobic functional group and silanol ligands is impregnated in $Nafion^{(R)}$ membrane to reduce methanol crossover. The prepared FAS/Nafion inorganic-organic composite electrolyte membrane consist of the hydrophobic FAS-derived silicate nano-particles and $Nafion^{(R)}$ matrix showed decrease of methanol crossover and reduction of humidity dependence without large sacrifice of proton conductivity. The microstructural analysis of the composite membranes was performed using FESEM and FTIR. And the effect of the incorporation of the hydrophobic FAS-derived silicate nano-particles into $Nafion^{(R)}$ membrane was investigated via solvent uptake, membrane expansion rate, humidity dependency of proton conductivity and contact angle measurement.

A Study on the Ionic Conducting Characteristics of Electrolyte Membranes Containing KI and $I_2$ for Dye Sensitized Solar Cell (염료감응형 태양전지를 위한 KI 및 $I_2$를 포함하는 유기/무기 복합 전해질막의 이온전도특성에 대한 연구)

  • Kang, Tae-Un;Shin, Chun-Hwa;Choi, Mi-Jung;Koo, Ja-Kyung;Cho, Nam-Jun
    • Membrane Journal
    • /
    • v.20 no.1
    • /
    • pp.21-28
    • /
    • 2010
  • Organic/inorganic composite electrolyte membranes were prepared for dye sensitized solar cell (DSSC). Poly (ethylene glycol) (PEG)s with various molecular weight (600, 1,500, 2,000 and 3,400) were ethoxysilated to fabricate organic/inorganic composite materials through sol-gel processes. The electrolyte membranes were produced by doping the composite materials with KI and $I_2$, and their ionic conducting behaviors were investigated. The ionic conductivity of the composite membrane was highly affected by PEG molecular weight. The highest conductivity was shown by the composite membrane prepared with PEG with the molecular weight of 2,000. The composite electrolyte membranes showed considerable improvement of ionic conductivity. Compared to PEO electrolyte membranes, the composite electrolyte membrane by PEG, MW 2,000 showed much higher ionic conductivity.

Preparation and application of gel type polymer electrolyte for PEFC (PEFC 연료전지용 겔 타입 고분자 전해질 합성 및 응용)

  • Lee, Sang-Yong;You, Ji-Yeon;Kim, Han-Joo;Oh, Mee-Hye;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.42-45
    • /
    • 2003
  • Inorganic polymer based hybrid membranes consisting of zirconium oxide and polydimethylsiloxane (PDMS) have been synthesized by sol-gel processes. The hybrid membranes showed thermal stability and flexibility up to $300^{\circ}C$. The membrane becomes proton conducting polymer electrolyte when added with 12-phosphotungstic acid (PWA). The conductivity of the membranes was measured in the temperature range from room temperature to $150^{\circ}C$ under saturated humidity and a maximum conductivity of $5{\times}10^{-5}\;Sm^{-1}$ was obtained at $150^{\circ}C$.

  • PDF