A Study on Performance Evaluation for Oil Mist Removal using a High-speed Centrifugal Cyclone (고속원심분리 사이클론을 이용한 오일 미스트 제거 성능 연구)

  • Kim, SooYeon;Kim, Jin-Seon;Sung, Jin-Ho;Han, Bangwoo;Kim, Yong-Jin;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.139-148
    • /
    • 2019
  • This study was performed for the application of a high-speed centrifugal cyclone to shale gas mining process. This device uses the centrifugal force to control particles similar to typical cyclones, and the disk located inside the cyclone is forced to rotate using a motor. The pressure difference occurred during the rotating of disk. Hence, inflow rate was generated without a blower fan. In addition, flow rate increased with elevating rpm of motor. The installing the disk in multiple stages on the inner rotor increased the instantaneous disk outlet flow. Hence, the control efficiency of oil particle increased from 1.05% to 31.2%. By modifying the structure of the disk so that the air flow to the opposite direction of the cyclone, the control efficiency of oil particles increased to 81.5%. By increasing the capacity of the motor and the size of the disk, the flow rate was increased to 2.5 ㎥/min because the rpm of motor and pressure difference increased. As rpm of motor increased, the cut-off diameter (dpc) became smaller. Unlike the Lapple's equation, dpc was inversely proportional to the effective number of rotations (Ne). The control efficiency was maintained even if the concentration of oil particles increased, for this reason, the higher the oil concentration, the more particles were accumulated and controlled.

Environmental Prediction in Greenhouse According to Modified Greenhouse Structure and Heat Exchanger Location for Efficient Thermal Energy Management (효율적인 열에너지 관리를 위한 온실 형상 및 열 교환 장치 위치 개선에 따른 온실 내부 환경 예측)

  • Jeong, In Seon;Lee, Chung Geon;Cho, La Hoon;Park, Sun Yong;Kim, Seok Jun;Kim, Dae Hyun;Oh, Jae-Heun
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.278-286
    • /
    • 2021
  • In this study, based on the Computational Fluid Dynamics (CFD) simulation model developed through previous study, inner environmenct of the modified glass greenhouse was predicted. Also, suggested the optimal shape of the greenhouse and location of the heat exchangers for heat energy management of the greenhouse using the developed model. For efficient heating energy management, the glass greenhouse was modified by changing the cross-section design and the location of the heat exchanger. The optimal cross-section design was selected based on the cross-section design standard of Republic of Korea's glass greenhouse, and the Fan Coil Unit(FCU) and the radiating pipe were re-positioned based on "Standard of greenhouse environment design" to enhance energy saving efficiency. The simulation analysis was performed to predict the inner temperature distribution and heat transfer with the modified greenhouse structure using the developed inner environment prediction model. As a result of simulation, the mean temperature and uniformity of the modified greenhouse were 0.65℃, 0.75%p higher than those of the control greenhouse, respectively. Also, the maximum deviation decreased by an average of 0.25℃. And the mean age of air was 18 sec. lower than that of the control greenhouse. It was confirmed that efficient heating energy management was possible in the modified greenhouse, when considered the temperature uniformity and the ventilation performance.

High Ejaculation Frequency Enhances Semen Production in Taiwan Country Chickens

  • Fan, Y.K.;Ju, J.C.;Lee, S.L.;Chen, C.F.;Peh, H.C.;Hsu, J.C.;Lee, Y.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.7
    • /
    • pp.924-929
    • /
    • 2004
  • The objective of this study were to investigate the effect of ejaculation frequency on semen characteristics and to establish a method for quick assessment of sperm concentration in TCC using packed cell volume (PCV) as the parameter (Trial 1). Eighty senior roosters, averaging 61 wk-old, were used and the sperm concentrations were determined using a hemacytometer. The PCV value was measured in a capillary (0.75 mm in inner diameter) by centrifugation. A simple linear regression analysis suggested that the sperm concentrations were significantly correlated with PCV values (r=0.62, p<0.001). Trial 2 was conducted to determine the optimal ejaculation frequency of TCC roosters in a weekly semen collection program. The male birds were subjected to 1, 2, 3 or 6 ejaculations per week for four consecutive weeks and semen characteristics including ejaculation volume (EV, mL), sperm motility (%), PCV (%), sperm concentration (ESC, $\times$10$^{9}$/mL), weekly sperm production (WSP, $\times$10$^{9}$/wk) and average motile sperm numbers (AMSN, $\times$10$^{9}$/ejac) were determined. Average EV was greater in the group with 3 ejac/wk than with only 1 ejac/wk in weeks 1 and 3 of the collection period. WSP increased with ejaculation frequency during the first 3 weeks of collection (p<0.05). Sperm motility was better in the birds with 6 ejac/wk than in single ejaculation group for the first 2 wk and no significant differences were found for the last 2 wk of study. In contrast, the PCV value showed a trend of reduction for the first 2 wks in the 6 ejac/wk group. Surprisingly, no significant differences were detected in the AMSN among treatment groups. The weekly motile sperm production (WMSP) increased with ejaculation frequency. Based on our observation, PCV values could be used for a quick estimation of sperm concentration and an intensive semen collection program enhanced weekly sperm production in TCC roosters.

Effect of Reversible Air-circulation Fans on Air Uniformity in a Cultivation Facility for Oyster Mushroom (느타리재배사 정역 제어 대류팬이 공기 균일도에 미치는 영향)

  • Yum, Sung Hyun;Kim, Si Hwan
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.383-392
    • /
    • 2021
  • It has been known that oyster mushrooms cultivated in facilities with thermal insulation have been strongly affected by inner environments. Forced air-circulation fans exert much direct influence on disturbing air inside the facility so the matter is of particular interest. This study is carried out to investigate the measured levels of air uniformity in a cultivation facility for oyster mushroom in the various cases that reversibly controlled air-circulation fans which drove the flow in the upward and reverse direction by turn and unidirectional fans by which the wind blew upwards only were operated from July 1 to 10. The actual survey for the selection of ongoing operation cases presented that farmers, even though there were some discrepancies, have made use of fans in a way that it paused for 5-30min after running for 5-15min by turn. The level of air uniformity in the case of adopting reversible fans revealed a slight difference of 1.4-1.8℃ (Temp.) and 7.8-8.7% (R.H.) under the condition of not using a cooler during the investigation period. By contrast, unidirectional fans showed a noticeable difference of 3.2-3.7℃ and 14.0-15.4%, which meant that air uniformity driven by reversible fans much more increased compared to that for unidirectional fans. Among the twenty operational applications considered for reversible fans, the circumstance that the wind blew upwards for 10-15min and ceased for 5-10min and blew again in the reverse direction for 10-15min in succession gave minor improvements at the level of air uniformity, but at present there was somewhat difficult to make decision on which cases were optimally best. It seems necessary that the effects of reversible fans on air uniformity as well as qualities of oyster mushrooms have to be appraised in the cultivation period and the flow visualization needs to be done to ascertain the performance of air mixture.

Study of Scatter Influence of kV-Conebeam CT Based Calculation for Pelvic Radiotherapy (골반 방사선 치료에서 산란이 kV-Conebeam CT 영상 기반의 선량계산에 미치는 영향에 대한 연구)

  • Yoon, KyoungJun;Kwak, Jungwon;Cho, Byungchul;Kim, YoungSeok;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • The accuracy and uniformity of CT numbers are the main causes of radiation dose calculation error. Especially, for the dose calculation based on kV-Cone Beam Computed Tomography (CBCT) image, the scatter affecting the CT number is known to be quite different by the object sizes, densities, exposure conditions, and so on. In this study, the scatter impact on the CBCT based dose calculation was evaluated to provide the optimal condition minimizing the error. The CBCT images was acquired under three scatter conditions ("Under-scatter", "Over-scatter", and "Full-scatter") by adjusting amount of scatter materials around a electron density phantom (CIRS062, Tissue Simulation Technology, Norfolk, VA, USA). The CT number uniformities of CBCT images for water-equivalent materials of the phantom were assessed, and the location dependency, either "inner" or "outer" parts of the phantom, was also evaluated. The electron density correction curves were derived from CBCT images of the electron density phantom in each scatter condition. The electron density correction curves were applied to calculate the CBCT based doses, which were compared with the dose based on Fan Beam Computed Tomography (FBCT). Also, 5 prostate IMRT cases were enrolled to assess the accuracy of dose based on CBCT images using gamma index analysis and relative dose differences. As the CT number histogram of phantom CBCT images for water equivalent materials was fitted with a gaussian function, the FHWM (146 HU) for "Full-scatter" condition was the smallest among the FHWM for the three conditions (685 HU for "under scatter" and 264 HU for "over scatter"). Also, the variance of CT numbers was the smallest for the same ingredients located in the center and periphery of the phantom in the "Full-scatter" condition. The dose distributions calculated with FBCT and CBCT images compared in a gamma index evaluation of 1%/3 mm criteria and in the dose difference. With the electron density correction acquired in the same scatter condition, the CBCT based dose calculations tended to be the most accurate. In 5 prostate cases in which the mean equivalent diameter was 27.2 cm, the averaged gamma pass rate was 98% and the dose difference confirmed to be less than 2% (average 0.2%, ranged from -1.3% to 1.6%) with the electron density correction of the "Full-scatter" condition. The accuracy of CBCT based dose calculation could be confirmed that closely related to the CT number uniformity and to the similarity of the scatter conditions for the electron density correction curve and CBCT image. In pelvic cases, the most accurate dose calculation was achievable in the application of the electron density curves of the "Full-scatter" condition.