• 제목/요약/키워드: Inner ear

검색결과 106건 처리시간 0.025초

전기 모델에 의한 완전 이식형 인공중이용 차동 전자 트랜스듀서의 진동 특성 해석 (Vibration characteristic analysis of differential floating mass transducer using electrical model for fully-implantable middle ear hearing devices)

  • 김민우;김민규;성기웅;임형규;정의성;한지훈;박일용;조진호
    • 센서학회지
    • /
    • 제16권3호
    • /
    • pp.165-173
    • /
    • 2007
  • A differential floating mass transducer has been developed in Korea for fully implantable middle ear hearing devices (F-IMEHDs). In particular, the performance of a differential floating mass transducer (DFMT) is very important among the parts of the F-IMEHDs because the mechanical vibration generated by DFMT is delivered to the inner ear directly. In this paper, the electrical model is proposed to analyze the DFMT vibration characteristic using the mechanical model of the DFMT. The electrical model enables the simple analysis of DFMT vibration characteristics using a computer program. The proposed electrical model is simulated through PSpice as changing the values of passive elements in the electrical model. To verify the proposed model, the DFMT has been implemented on the basis of the simulated results and the experiment for vibration measurement has been carried out. Through the comparison, it is verified that the proposed model is useful to analyze the vibration characteristics of the DFMT.

차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 실험적 검증 (Experimental Verification of Implantable Middle Ear System using the Differential Electromagnetic Type Transducer)

  • 송병섭;이기찬;원철호;박세광;이상흔;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권3호
    • /
    • pp.217-225
    • /
    • 2002
  • 이식형 인공중이는 일반적인 공기전도형 보청기가 가지는 난점인 고이득에서의 왜곡과 음향 피이드백에 의한 링잉 현상을 해결할 수 있는 동시에 음질과 주파수 특성 및 청음명료도가 우수하다 본 논문에서는 마이크로머시닝 기술을 이용하여 차동 전자 트랜스듀서를 제작한 후 이를 사용하여 이식형 인공중이 시스템을 구현하였다. 제작된 시스템을 이용하여 무부하 진동실험. 사체를 이용한 부하진동실험 및 살아있는 개를 이용하여 동물이식실험을 실시함으로써 이의 성능을 확인하였다. 무부하 진동실험을 통하여 제작된 트랜스듀서는 입력되는 소리신호와 같은 형태의 진동을 일으킴을 확인하였고, 사체의 이소골에 트랜스듀서를 이식하고 부하실험을 실시함으로써 트랜스듀서의 이소골 구동능력과 진동특성을 조사하였다. 그리고 개를 이용하여 동물이식실험을 실시한 후 뇌간 유발 반응검사를 실시함으로써 생체 내에서의 이식형 인공중이의 동작을 확인하였다. 이를 통하여 제작된 차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 성능을 검증하였고 난청자에게 적용할 경우에도 잘 동작할 수 있음을 증명함으로써 임상실험을 실시할 수 있는 근거를 마련하였다.

Ingestion of Korean Red Ginseng after Noise Exposure Can Potentiate Rapid Recovery of Hearing in Mice

  • Kang, Woo-Seok;Chung, Jong-Woo
    • Journal of Ginseng Research
    • /
    • 제34권4호
    • /
    • pp.336-341
    • /
    • 2010
  • One mechanism of inner ear damage by noise-induced hearing loss (NIHL) is the production of reactive oxygen species (ROS). Because Korean red ginseng (KRG) has an anti-ROS effect in various tissues, KRG may have a role in preventing NIHL. A window period exists in which ROS formations continue after noise exposure, and further damage can be prevented by antioxidants. In this study, we aimed to investigate the effects of KRG after exposure to noise. KRG (200 mg/kg) was fed to mice for 3 days after noise exposure. The change in hearing level was analyzed by measuring the auditory brainstem response. To induce a temporary threshold shift (TTS) of hearing, mice were exposed to 110 dB white noise for 3 hours. Fast recovery of hearing was observed in mice fed KRG 1 hour and 1 day after noise exposure for 3 days. The expression of 8-oxoguanine was not observed in the inner ears of mice fed KRG 1 hour after noise exposure, but was evident in the stria vascularis of mice in the control group (noise exposure only). From this study, we conclude that KRG acted as an effective inhibitor of NIHL in TTS cases.

NEW ANTI-AGING AND ANTI-WRINKLE COSMETIC INGREDIENT : INNER NUTSHELL OF CASTANEA MOLLISIMA BL (CHESTNUT)

  • Kim, Beom-Jun;Kim, Jeong-Ha;Kim, Hyun-Pyo;Heo, Moon-Young
    • 대한화장품학회지
    • /
    • 제24권3호
    • /
    • pp.17-23
    • /
    • 1998
  • Inner nutshell of Castanea mollisima BL (chestnut) has been used as an anti-aging and anti-wrinkle agent from the ancient time in east Asia. In order to develop new anti-aging and anti-wrinkle, ethanolic extract of inner nutshell of Castanea mollisima BL (Cor-285) was prepared and various biological activities were evaluated. Cor-285 showed potent antioxidant activity, Especially, Cor-285 possessed potent free radical scavenging activity in vitro (IC50:7.6 g/ml) compared to gallic acid (IC50:12.5 g/ml), Cor-285 showed the preventive effect against UV-induced cytotoxicity of fibroblast at concentration of 25-250 g/ml. When Cor-285 was evaluated for its anti-allergic activity, it effectively inhibited histamine release from mast cells induced by compound 48/80 (86% inhibition at 10 mg/ml). The inhibitory activity was stronger than that of glycyrrhiznate. Cor-285 also showed in vivo inhibition against delayed hypersensitivity as well as croton-oil induced ear edema in mice when topically applied These results strongly suggest that Cor-285 may reduce immunoregulatory 1 inflammatory skin trouble. From the attempts to isolate the constituents, citropten (simple coumarin) and ellagic acid, a well known radical scavenger, were isolated. In a clinical trial of twenty healthy volunteers with aged skin,6 weeks application of Cor-285 (3% cream) decreased wrinkle about 26% and increased moisturizing 20% on the skin. All of these results indicate that Cor-285 may be an effective anti-aging and anti-wrinkle agent.

  • PDF

수중 저주파에 의한 능성어 (Epinephelus septem fasciatus)의 행동제어에 관한 기초적 연구 I. 능성어의 청각문턱치 (A basic study for the behaviour control of sevenband grouper, Epinephelus septem fasciatus, to underwater low frequency sound I. The Auditory thresholds of sevenband grouper)

  • 양용수
    • 수산해양기술연구
    • /
    • 제35권4호
    • /
    • pp.391-396
    • /
    • 1999
  • It is well known that fish hear a wide frequency range of sound using both laterial line and inner ear, and the sound is probably the most effective channel for long-range communication underwater than any other stimulus.The auditory threshold of svenband grouper, Epinephelus septem fasciatus was determined by conditioning method using a sound coupled with electric shock in a tank. The audio-signals and electric shock used in the experiment were pure tones of 100 to 1000Hz and DC 6n.The response of fish to the sound was observed by ECG intervals from precordial leads method (V1·V2 method). The auditory threshold curve for sevenband grouper was V-shaped, with most sensitive threshold at 350Hz in the range of 100~1000Hz. The Sevenband grouper were more sensitive to sounds of 200~400Hz than to adjacent frequencies.

  • PDF

Blood-neural barrier: its diversity and coordinated cell-to-cell communication

  • Choi, Yoon-Kyung;Kim, Kyu-Won
    • BMB Reports
    • /
    • 제41권5호
    • /
    • pp.345-352
    • /
    • 2008
  • The cerebral microvessels possess barrier characteristics which are tightly sealed excluding many toxic substances and protecting neural tissues. The specialized blood-neural barriers as well as the cerebral microvascular barrier are recognized in the retina, inner ear, spinal cord, and cerebrospinal fluid. Microvascular endothelial cells in the brain closely interact with other components such as astrocytes, pericytes, perivascular microglia and neurons to form functional 'neurovascular unit'. Communication between endothelial cells and other surrounding cells enhances the barrier functions, consequently resulting in maintenance and elaboration of proper brain homeostasis. Furthermore, the disruption of the neurovascular unit is closely involved in cerebrovascular disorders. In this review, we focus on the location and function of these various blood-neural barriers, and the importance of the cell-to-cell communication for development and maintenance of the barrier integrity at the neurovascular unit. We also demonstrate the close relation between the alteration of the blood-neural barriers and cerebrovascular disorders.

말초 청각 계통 모델을 이용한 한국어 모음 인식 (Korean Vowel Recognition using Peripheral Auditory Model)

  • 윤태성;백승화;박상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권1호
    • /
    • pp.1-10
    • /
    • 1988
  • In this study, the recognition experiments for Korean vowel are performed using peripheral auditory model. In addition, for the purpose of objective comparison, the recognition experiments are performed by extracting LPC cepstrum coefficients for the same speech data. The results are as follows. 1) The time and the frequency responses of the auditory model show that important features of input signal are involved in the responses of inner ear and auditory nerve. 2) The recognition results for Korean vowel show that the recognition rate by auditory model output is higher than the recognition rate by LPC cepstrum coefficients. 3) The adaptation phenomenon of auditory nerve provides useful characteristics for the discrimination of vowel signal.

  • PDF

청각보철장치용 어음발췌기의 하드웨어 구현 (H/W Implementation of Speech Protestor for Cochlear Implant)

  • 신중인;박상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.161-162
    • /
    • 1998
  • In this paper, a speech processor which is the most important part of the cochlear implant is developed, to recover auditory ability for the sensorineural disorders who have damaged for their inner ear. This system consists of the analog and digital signal processing part, of which functions is the pre-processing and the main processing, respectively. The main processing is peformed in DSP processor (TMS320C31-40) by using S/W. Because the program is used in this system, it is possible to cope with the individual status of the patients, very easily.

  • PDF

담훈(痰暈)으로 변증된 양성 돌발성 체위성 현훈의 치험 4례 (Four Cases of Benign Paroxysmal Positional Vertigo Diagnosed as Damhun)

  • 이재화;이성근;김영은
    • 동의생리병리학회지
    • /
    • 제23권3호
    • /
    • pp.734-739
    • /
    • 2009
  • Benign paroxysmal positional vertigo(BPPV) is the most common peripheral vestibular disorder clinically. It causes dizziness or vertigo, lightheadedness, imbalance, and nausea. by a change of position of the head with respect to gravity. BPPV is very well explained by mechanical consequences of loose debris within the inner ear and oriental medical theory of vertigo resulting from Phlegm(痰). Therefore, for treatment of BPPV, we can consider not only oriental medical therapy but also Canalith Repositioning Procedure. We report four improved cases of dizziness patient diagnosed BPPV and Dam Hun(痰暈) treated by canalith repositioning procedure and herbal medication and acupuncture.

철도차량용 복합 내장 패널의 차음성능에 관한 연구 (A Study on the Sound Insulation Performance of the Composite Panel for Railroad Vehicle)

  • 김봉기;김재승;황병선;이상진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.182-187
    • /
    • 2002
  • Since most of main noise sources of the railroad vehicle are transmitted to the passenger's ear through the vibration of the panel, the insulation performance of the panels should be high enough to protect the passengers from the noisy environment. Specifically, the composite materials which are generally used for reducing the weight of the vehicle compartment have the low insulation performance, noise control actions should be taken appropriately by considering the insulation performance of the panels. In this study, the insulation performances of the inner/outer panels were evaluated and the contribution of the aluminum door was estimated compared to the composite panels. The results can furnish an indepth understanding of the insulation characteristics of the panel of railroad vehicle.

  • PDF