• Title/Summary/Keyword: Inner cannula

Search Result 7, Processing Time 0.016 seconds

Saving Effects Cost and Time in Nursing through Improving Sterilization Method of Inner Cannula (기관내관 소독 방법 개선에 따른 간호업무 시간단축 및 비용 절감 효과)

  • Yi, Haeng-Seon;Kim, Haerina;Kim, Eun-Suk;Kim, Bo-Ram;Seong, Seon-Suk
    • Quality Improvement in Health Care
    • /
    • v.14 no.1
    • /
    • pp.55-59
    • /
    • 2008
  • Background : The purpose of inner cannula is to protect the upper air way and permit air to pass freely, in addition, to provide endotracheal suction, artificial respiration and to maintain adequate oxygen saturation. The tube needs to be sterilized for maintenance and cleanness of air way and for prevention of bronchospasm. However, it has been reported that there is no guideline for sterilization and many hospitals conduct their own sterilization methods, for example, once a day(13's general hospital), three times a day(The Catholic University of Korea ST Mary's hospital) or even no cleansing. Consequently, the QI team of our hospital suggested the SOP(standard operating procedure) of sterilization and evaluate cost and time effect in nursing. Method : 1) Benchmarking of 13's neurosurgery department of general hospital in Seoul 2) Investigation of test records of sputum culture from patients with intubation for tracheotomy 3) Check of results of O2 Sat. monitoring to confirm of maintaining opened air way Result : 1) Improvement of process: decrease of excess sterilization of inner cannula (from 3 times a day to once a day) 2) Cost effects: saving over 10 million won per one year 3) Providing better nursing: time effects (30 min a day) permit to conduct more nursing activities Conclusion : It can get Cost and time effects in nursing with improved sterilization method of inner cannula. It needs to do research on improvement of the monthly exchange protocol of outer cannula and provide supporting data for the proper exchange schedule. The result of additional microorganism detection from patients with new process needs to be evaluated further more.

  • PDF

An Experiments Analysis of Comparison of Flow Gradients Across Disposable Arterial Perfusion Cannulas (일회용 각종 송혈관의 관류압차에 대한 비교실험)

  • Kim, Yo-Han;Kim, Hyeong-Muk
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.18-24
    • /
    • 1986
  • The mean perfusion pressure produced by 20 different design and size of disposable aortic perfusion cannulas [size range: 18F to 20F] at flow rates of 1 to 5 L/min was compared. A roller pump with perfusion tubing 10mm in inner diameter was used with a mixture of 0.9% normal saline and 100% glycerin [mixing ratio of 6.72:13.28] to make the viscosity as normal blood in 20oC as the test solution. Line pressure in these cannulas at a flow rate of 3L/min ranged from 13.2$\pm$4.47 to 157$\pm$1 34 mmHg in a case of absence of resistance, and from 11.4$\pm$1.14 to 227.2$\pm$4.47 mmHg in a case of presence of resistances 14 cannulas had gradients of less than 100Hg at a flow rate of 3L/min and 9 cannulas less than 100mmHg at 4L/min. The following results were obtained from this experimental study: .1] A wide range of line pressure was observed in disposable aortic perfusion cannulas currently in clinical use; 2] Some cannulas currently used for cardiopulmonary bypass in adults generated excessive line pressure; 3] Both the material and design affect function, with some designs safer than others. Cardiac surgeons should base the choice of aortic perfusion cannula on the best performance and safest design available to avoid cannula-related problems during operation.

  • PDF

Effect of Fungal Elimination on Bacteria and Protozoa Populations and Degradation of Straw Dry Matter in the Rumen of Sheep and Goats

  • Li, D.B.;Hou, X.Z.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.1
    • /
    • pp.70-74
    • /
    • 2007
  • An in vitro study was carried out to investigate the differences in rumen microbes and fiber degradation capacity between sheep and goats. Three local male sheep and three Inner Mongolia male cashmere goats (aged 1.5 to 2 years; weight 25.0 to 32.0 kg) were each fitted with a permanent rumen cannula used to provide rumen fluid. Cycloheximide was used to eliminate rumen anaerobic fungi. The results showed that the quantities of fungal zoospores in the culture fluid of the control group were significantly greater in the sheep than in the goats; however, bacteria and protozoa counts were significantly higher in goats than in sheep. The digestibility of straw dry matter did not differ significantly between the two species before elimination of fungi, but tended to be higher for sheep (55.4%) than for goats (53.3%). The results also indicated that bacteria counts increased significantly after elimination of anaerobic fungi; however, the digestibility of straw dry matter significantly decreased by 12.1% and 8.6% for sheep and goats respectively. This indicated that the anaerobic fungi of the rumen played an important role in degradation of fiber.

A Study on the Optimal Amino Acid Pattern at the Proximal Duodenum in Growing Sheep

  • Wang, Hongrong;Lu, Dexun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.1
    • /
    • pp.38-44
    • /
    • 2002
  • Nine crossbred castrated lambs fitted with rumen and duodenum cannula and fed a diet of hay and concentrate formulated with ground corn and soybean meal as main ingredients were used to assess the duodenal ideal amino acid pattern. Three synthetic amino acid mixtures with different profile of essential amino acids were duodenally infused in order to get three different amino acid patterns flowing into the duodenum. The mixtures were designed to have similar amino acid profile as rumen microbial protein (Pm), casein (Pc) and modified muscle amino acid (Pmm). Results showed a lower urine nitrogen excretion (p=0.05), a higher nitrogen retention (p=0.04) and bodyweight gain with treatment Pmm. The modified muscle amino acid pattern also promoted a lower ratio of Gly to other amino acids in plasma (Gly/OAA) and a higher RNA and RNA/DNA concentration in the liver of the sheep. Meanwhile, the urea concentration in plasma was reduced and the insulin concentration was increased with Pmm treatment. No differences in glucose and growth hormone concentration in plasma were found among three treatments. All results obtained indicate that the modified muscle amino acid pattern (Lys 100%, Met+Cys 39%, Thr 76%, His 41%, Arg 72%, Leu 158%, Ile 81%, Val 105%, Phe 81% and Trp 13%) was the best for growing sheep.

Sutureless Laparoscopic Ovariectomy in Small Dogs Using Two 3-mm Portal Sites

  • Hyeon-Han Ku;Ho Hyun Kwak;Jun-Hyung Kim;Kyung-Mee Park;Heung Myong Woo
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.319-325
    • /
    • 2022
  • Two-port laparoscopic ovariectomy (Lap-OVE) has been performed in small dogs, using 3-mm and 5-mm portal sites, and is associated with reduced surgical stress and postoperative pain. However, extension of the incision is often needed to extract the ovaries. In this study, we aimed to minimize invasiveness by using smaller-sized cannulas as well as a novel technique for ovary extraction. Lap-OVE was performed on six, healthy female dogs (range, 3 to 7.2 kg) using two 3-mm midline portals. The middle finger of a size M nitrile glove was cut at its base and sterilized preoperatively. The ovary was suspended at the body wall using a 1-0 blue nylon needle, and the ovarian pedicle and ligaments were transected using a 3-mm bipolar forceps. To facilitate the glove passing through the 3.9-mm port, it was turned inside out to expose the smooth inner surface, before being inserted into the abdominal cavity with an applicator. Both ovaries were placed inside, and the mouth of the glove was exteriorized through the port with a laparoscopic grasping forceps. The ovaries were morcellated inside the glove, using Adison-Brown tissue forceps and iris scissors, which enabled safe extraction without incision enlargement. Median incision lengths were 4.3 mm (3.5-mm cranial cannula) and 4.8 mm (3.9-mm caudal cannula). An advantage of this procedure was that there was no need for skin sutures. In conclusion, using our novel technique, sutureless Lap-OVE was possible in small dogs using two 3-mm portal sites without additional incision.

Geometrical Design and SLIPS Lubrication for Enhancement of Negative-pressure-driven Internal Flow Rate in Metal Pipes (금속관 내부의 음압유량 향상을 위한 기하학적 디자인 및 SLIPS 윤활)

  • Kim, Dong Geun;Jang, Changhwan;Kim, Seong Jae;Kim, Daegyoum;Kim, Sanha
    • Tribology and Lubricants
    • /
    • v.37 no.6
    • /
    • pp.253-260
    • /
    • 2021
  • Metal pipes are used in a wide range of applications, from plumbing systems of large construction sites to small devices such as medical tools. When a liquid is enforced to flow through a metal pipe, a higher flow rate is beneficial for higher efficiency. Using high pressures can enhance the flow rate yet can be harmful for medical applications. Thus, we consider an optimal geometrical design to increase the flow rate in medical devices. In this study, we focus on cannulas, which are widely used small metal pipes for surgical procedures, such as liposuction. We characterize the internal flow rate driven by a negative pressure and explore its dependence on the key design parameters. We quantitatively analyze the suction characteristics for each design variable by conducting computational fluid dynamics simulations. In addition, we build a suction performance measurement system which enables the translational motion of cannulas with pre-programmed velocity for experimental validation. The inner diameter, section geometry, and hole configuration are the design factors to be evaluated. The effect of the inner diameter dominates over that of section geometry and hole configuration. In addition, the circular tube shape provides the maximum flow rate among the elliptical geometries. Once the flow rate exceeds a critical value, the rate becomes independent of the number and width of the suction holes. Finally, we introduce a slippery liquid-infused nanoporous surface (SLIPS) coating using nanoparticles and hydrophobic lubricants that effectively improves the flow rate and antifouling property of cannulas without altering the geometrical design parameter.

Modified Inside-Out Suture Technique for Meniscus Repair (변형된Inside-Out 술식을 이용한 반월상 연골 봉합술)

  • Ahn Jin-Hwan;Wang Joon-Ho;Yoo Jae-Chul;Kim Hyung-Gun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.2
    • /
    • pp.118-123
    • /
    • 2002
  • Purpose: To report modified technique of inside-out suture in repair of tear of postero medial corner of medial meniscus. Operative technique: Arthroscope is placed through anterolateral portal. Suture hook is delivered through anteromedial portal. By rotating the suture hook, it penetrates the inner portion of the torn meniscus from femoral surface to tibial surface of the meniscus for vertically oriented suture. A PDS suture is delivered through the lumen of suture hook, and the suture hook is withdrawn. The both ends of the suture are retrieved through anteromedial portal by a retriever, either grasper or crochet hook.A Zone-specific cannula is positioned below the inferior surface of the meniscus through anterolateral portal. The Looped Needle designed by the authors is delivered through the lumen of the Zone-specific cannula. The suture end of the tibial surface is placed in the loop of the Looped Needle and pulled out to the surface of posteromedial joint line. The suture end of the femoral surface is pulled out in same manner. A transverse skin incision of 1cm size is made adjacent to pulled out suture and the suture is tied. Discussion: Even though modified inside-out suture technique requires longer operation time than conventional inside-out technique, it provides vertically oriented suture and good tissue coaptation. The authors recommend this modified inside-out suture technique to be good alternative in repairing tear of the posteromedial corner of medial meniscus.

  • PDF