• 제목/요약/키워드: Inlet-Air Temperature

검색결과 674건 처리시간 0.028초

다점 피토관을 이용한 기체 유량 측정의 불확도 평가 (Uncertainty Assessment of Gas Flow Measurement Using Multi-Point Pitot Tubes)

  • 양인영;이보화
    • 한국유체기계학회 논문집
    • /
    • 제19권2호
    • /
    • pp.5-10
    • /
    • 2016
  • Gas flow measurement in a closed duct was performed using multi-point Pitot tubes. Measurement uncertainty was assessed for this measurement method. The method was applied for the measurement of air flow into a gas turbine engine in an altitude engine test facility. 46 Pitot tubes, 15 total temperature Kiel probes and 9 static pressure tabs were installed in the engine inlet duct of inner diameter of 264 mm. Five tests were done in an airflow range of 2~10 kg/s. The flow was compressible and the Reynolds numbers were between 450,000 and 2,220,000. The measurement uncertainty was the highest as 6.1% for the lowest flow rate, and lowest as 0.8% for the highest flow rate. This is because the difference between the total and static pressures, which is also related to the flow velocity, becomes almost zero for low flow rate cases. It was found that this measurement method can be used only when the flow velocity is relatively high, e.g., 50 m/s. Static pressure was the most influencing parameter on the flow rate measurement uncertainty. Temperature measurement uncertainty was not very important. Measurement of boundary layer was found to be important for this type of flow rate measurement method. But measurement of flow non-uniformity was not very important provided that the non-uniformity has random behavior in the duct.

소재변경에 따른 차량용 스크롤압축기의 열변형 해석 (Thermal Deformation Analysis of a Scroll Compressor for Automobile according to the Change of Materials)

  • 이형욱;이근안;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.67-74
    • /
    • 2014
  • An inverter scroll compressor is used for the air conditioning in cars. Scrolls would be changed from the aluminum material to the magnesium material in order to satisfy the light weight trends of cars. The material changing influences on the scroll dimensions particularly the gap between two scrolls. Since the larger gap declines the performance of the compression, the gap between wraps of scrolls or the gap between wraps of scrolls to the plate of the opposite scroll is regarded as an important design variable. This paper is focused on the effects of the thermal stress due to the materials changing. The temperature difference between the inlet and the outlet is about 60 degrees and the highest operating temperature in the compressor is less than 110 degrees. The level of thermal stresses in the magnesium scroll is less than the result from aluminum one. The trend of the deformation is revealed that the normal directional deformation is 2 times lager than the in-plane directional deformation. Therefore the gap between the top of the wrap to the plate of the opposite scroll become more important than the other gaps. The orbiting scroll deforms larger than the fixed scroll by the thermal stresses. The deformation of the magnesium scroll is about 10% lager than that of the aluminum scroll. This value is similar to the ratio of the coefficients of thermal expansion of two materials. At the initial design stage, the results give many useful guides to engineers to propose gaps between parts.

흡수식 대온도차 시스템에서 2단 증발/흡수기의 성능 특성에 관한 수치적 연구 (Performance analysis for the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System)

  • 박찬우;강용태;임익태;문상돈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.304-308
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

냉수 대온도차 흡수식 냉동기용 2단 증발기/ 흡수기 최적 설계 (Optimum design of the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System)

  • 박찬우;임익태;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.203-211
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

곡물냉각기의 성능해석을 위한 시뮬레이션 (Simulation for Performance Analysis of a Grain Cooler)

  • 박진호;정종훈
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.449-460
    • /
    • 2001
  • This study was carried out to develop a simulation model with EES(Engineering equation solver) for analyzing the performance of a grain cooler. In order to validate the developed simulation model, several main factors which have affected on the performance of the gain cooler were investigated through experiments. A simulation model was developed in the standard vapor compression cycle, and then this model was modified considering irreversibe factors so that the developed alternate model could predict the actual cycle of a grain cooler. The compressor efficiency in vapor compression cycle considering irreversibility much affected on the coefficient of performance(COP). The COP in the standard vapor compression cycle model was greatly as high as about 6.50, but the COP in an alternative model considering irreversibility was as low as about 3.27. As a result of comparison between the actual cycle and the vapor compression cycle considering irreversibility, the difference of pressure at compressor outlet(inlet) was a little by about 48kPa (8.8kPa), the temperatures of refrigerant at main parts of the grain cooler were similar. and the temperature of chilled air was about 8$\^{C}$ in both. The model considering irreversibility could predict performance of the grain cooler. The theoretical period required to chill grain of 1,383kg from the initial temperature 24$\^{C}$ to below 11$\^{C}$ was about 55 hours 30 minutes, and the actual period required in a grain bin was about 58 hours. The difference between the predicted and an actual period was about 2 hours 30 minutes. The cooling performance predicted by the developed model could well estimate the cooling period required to chill the grain.

  • PDF

세관을 이용한 Tube-in-Tube 열교환기내 R-22, R-407C 및 R-410A 응축열전달 특성 (Condensation Heat Transfer Characteristics of Tube-in-Tube Heat Exchanger using Small Diameter Tubes with R-22, R-407C and R-410A)

  • 박우종;최광일;박기원;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.657-662
    • /
    • 2006
  • The present paper dealt with an experimental study of condensation heat transfer coefficients with refrigerant R-22, R-407C and R-410A, and was focused on pressure gradient and heat transfer coefficient in horizontal tube-in-tube heat exchangers using inner diameter of 4 mm, 3 mm and 2 mm in a 16.91 mm tube and length of 3,000 mm. Experiments were performed at inlet saturation temperature of 35 to $45^{\circ}C$ and mass flux ranges from 200 to $600 kg/m^2s$. The pressure gradient with inner tube diameter of 4.0 mm is higher 2.5 times than that of 8.0 mm. In tube-in-tube HEX, the pressure gradient of R-410A were lower than those of R-22 and R-407C. The condensation heat transfer coefficients increased with mass flux increase, but they decreased with saturation temperature increased. Condensation heat transfer coefficients of R-410A were a little higher than those of R-22 and R-407C. The condensation heat transfer coefficients of tube-in-tube HEX were about 40% higher than those of double tube HEX.

  • PDF

전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석 (Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability)

  • 주민정;서상욱;오재영;정현모;박종민
    • 한국포장학회지
    • /
    • 제28권2호
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.

일체형 PM/NOx 동시저감장치의 최적 설계에 대한 기초 연구 (A Basis Study on the Optimal Design of the Integrated PM/NOx Reduction Device)

  • 최수정;;이원주;김준수;김정국;박호용;임인권;최재혁
    • 해양환경안전학회지
    • /
    • 제28권6호
    • /
    • pp.1092-1099
    • /
    • 2022
  • 대기오염물질과 온실가스 배출량을 저감 시키기 위한 배기 후처리 장치에 대한 연구는 활발히 진행 중이지만 그 중 선박용 입자상물질/질소산화물(PM/NOx) 동시저감 장치에서는 엔진에 미치는 배압 및 필터 담체 교체에 대한 문제가 발생하고 있다. 본 연구에서는 PM/NOx를 동시저감 할 수 있는 일체형 장치의 최적 설계를 위해 장치 내부 유동과 입·출구 압력을 통한 배압의 변화를 연구하여 적절한 기준을 제시하였다. Ansys Fluent를 활용하여 디젤미립자필터(DPF) 및 선택적촉매환원법(SCR)에 다공성 매체 조건을 적용하였고 공극률은 30 %, 40 %, 50 %, 60 % 및 70 %로 설정하였다. 또한, 엔진 부하에 따른 Inlet 속도를 경계 조건으로 7.4 m/s, 10.3 m/s, 13.1 m/s 및 26.2 m/s로 적용하여 배압에 미치는 영향을 분석하였다. CFD 분석 결과, 장치의 입구 온도 보다 입구 속도에 따른 배압의 변화율이 크고 최대 변화율은 27.4 mbar였다. 그리고 모든 경계 조건에서의 배압이 선급 기준인 68 mbar를 초과하지 않았기 때문에 1800 kW 선박에 적합한 장치로 평가되었다.

퇴비화과정 중 공기공급 여부가 가축분뇨 퇴비의 물리화학적 특성에 미치는 영향 (Effect of aeration on the physicochemical characteristics of livestock feces compost during composting period)

  • 정광화;강호;김태일;박치호;양창범
    • 유기물자원화
    • /
    • 제11권4호
    • /
    • pp.57-65
    • /
    • 2003
  • 축산업은 수질이나 토양오염 그리고 대기오염에 미칠 수 있는 영향으로 인해 관심의 대상이 되는 산업에 포함되어 있다. 가축분뇨가 환경오염원이 될 수 있는 것은 사실이다. 이러한 가축분뇨를 처리할 수 있는 최상의 방법은 가축분뇨를 적절한 방법으로 퇴비화 하여 유기성 비료로서 재활용하는 것이다. 따라서 본 연구는 몇가지 방법의 퇴비화 조건에서 가축분뇨의 퇴비화 특성을 조사하기 위하여 실시되었다. 각기 다른 정도의 공기를 함유하는 퇴비단들의 물리화학적 특성을 퇴비화 전기간에 걸쳐 조사하였다. 본 실험에서는 돼지분뇨를 톱밥과 혼합하여 110L 크기를 가진 실험실 규모의 플라스틱 재질의 용기들과 목재로 된 $1.5m^3$ 크기의 소형 사각용기에 충진한 후 60일 동안의 퇴비화를 수행하였다. 시험 전 기간 동안 공기펌프로 퇴비단에 공기를 공급하였고 주입 공기량은 유입부에 설치된 밸브로 조절하였다. 공기주입량은 각 용기들에 따라 20, 50, 100, 150, $200L/m^3/mim$ 수준으로 하였다. 퇴비화 기간 동안 발효 최고 온도는 $72^{\circ}C$까지 상승하였다. 퇴비화 20일째에 송풍 처리구의 퇴비단 표면에서 포집된 가스에서의 $H_2S$, $CH_3SH$, DMS 그리고 DMDS 농도는 29, 16, 6, 5ppb 이었고 무송풍구에서의 농도는 각각 32, 24, 15, 14ppb의 수준을 나타냈다.

  • PDF

3압 복합 발전 플랜트 사이클에 대한 성능해석 (Performance Analysis of a 3 Pressured Combined Cycle Power Plant)

  • Kim, S. Y.;K. S. Oh;Park, B. C.
    • 한국추진공학회지
    • /
    • 제2권2호
    • /
    • pp.74-82
    • /
    • 1998
  • 복합발전 사이클은 가스터빈이나 스팀터빈으로부터의 출력을 이용하여 전개를 생산하기 위한 발전기를 구동시키고 배영회수기로부터 나온 증기를 스틸터빈에서 팽창시킴으로서 부가적인 동력을 얻는 장치를 가리킨다. 보통 가스터빈 배기로 부터의 온도는 $400{\sim}650^{\circ}C$정도로서 배열회수기에서 효과적으로 스팀을 생산할 수 있는 수준의 온도이다. 복합 사이클은 일반적으로 상부사이클과 하부사이클로 구분하는데 대부분의 열에너지 공급이 이루어지는 상부사이클을 브레이돈사이클 이라하며 브레이돈사이클에서 소비되는 에너지는 보다 낮은 온도 수준인 하부사이클에서 회수된다. 이러한 복합사이클은 최근 들어 더욱 보편적으로 적용되고 있는데 그 이유는 첫째, 가스터빈이나 스팀터빈이 독자적으로도 충분히 기술적인 검증을 받은 열기관으로서 초기에 비해 개발비가 저렴해졌다는 데 있고, 둘째, 작동유체인 공기가 $1000^{\circ}C$ 이상에서도 별다른 문제없이 적용될 수 있는 안전한 유체이고 비용이 전혀 들지 않는다는 점이다. 그 뿐 아니라 스팀터빈에 사용되는 물도 중저온에서 매우 저가로 공급할 수 있고 쉽게 공급이 가능하다는 이점으로 하부사이클에의 적용이 매우 양호하다는 점이다. 최근 소재기술의 개발에 따른 터빈입구온도의 향상은 이러한 복합발전 사이클의 기술적, 경제적 이점을 더욱 강화시켜 주고 있다. 본 연구에서는 3압에 의한 복합사이클에 대한 성능해석을 통하여 상부사이클이 전체 복합발전 성능에 미치는 영향을 조사하였으며 그 결과를 서인천 복합발전 인수 성능시험결과와 비교하였다. 본 연구결과는 현재 개념설계가 이루어지고 있는 장차 150~200MW수준의 산업용 가스터빈 개발에 중요한 방향제시를 할 수 있을 것으로 판단된다.

  • PDF