• Title/Summary/Keyword: Inlet throttling

Search Result 12, Processing Time 0.022 seconds

Effect of inlet throttling on thermohydraulic instability in a large scale water-based RCCS: An experimental study

  • Qiuping Lv;Matthew Jasica;Darius Lisowski;Zhiee Jhia Ooi;Rui Hu;Mitch Farmer
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.655-665
    • /
    • 2024
  • The objective of the present experimental study is to investigate the effect of inlet throttling on the thermohydraulic stability of a large scale water-based Reactor Cavity Cooling System (RCCS). The test was performed using the water-based Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne, which represented a ½ axial scale and 12.5° sector slice of the full scale Framatome 625 MWt SC-HTGR RCCS concept. A two-phase steady state was first established through direct condensate refill, followed by increased inlet throttling over 10 stages, corresponding to a loss coefficient K over the range of 0.05-653. With the inlet throttling gradually increased, the system experienced a unique transition process between stabilization and destabilization. Through a stability analysis, three instability mechanisms were identified in the present test, including a compound mechanism due to both natural circulation oscillations (NCOs) and density wave oscillations (DWOs), Type-II DWOs, and geysering.

A Study on Regeneration Characteristics in DPF(1) (매연여과장치의 재생특성에 관한 연구(1))

  • Lee, B.H.;Lee, S.J.;Choi, G.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.72-79
    • /
    • 1998
  • The goals of this research are to understand the regeneration characteristics in diesel particulate filter(DPF) using the cerium additive and throttling. The effects of throttling duration and spring tension of throttling valve were studied. Measurements were made on a 6 cylinder direct injection diesel engine and included pressure drop, filter inlet temperature, oxygen concentrations, and torque. The major conclusions of this work include; (i) the pressure drop is increased with increase of the engine load and the engine speed; (ii) the inlet temperature of the filter is reached $350^{\circ}C$ with certain engine operating condition which leads to sufficient temperature to regenerate with additive; and (iii) oxygen concentrations in the filter and engine torque during throttling operation are decreased by 2 percent and 36 percent, respectively, which are not critical about regeneration and vehicle operation.

  • PDF

Effects of Angles of Attack and Throttling Conditions on Supersonic Inlet Buzz

  • NamKoung, Hyuck-Joon;Hong, Woo-Ram;Kim, Jung-Min;Yi, Jun-Sok;Kim, Chong-Am
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.3
    • /
    • pp.296-306
    • /
    • 2012
  • A series of numerical simulations are carried out to analyze a supersonic inlet buzz, which is an unsteady pressure oscillation phenomenon around a supersonic inlet. A simple but efficient geometry, experimentally adopted by Nagashima, is chosen for the analysis of unsteady flow physics. Among the two sets of simulations considered in this study, the effects of various throttling conditions are firstly examined. It is seen that the major physical characteristic of the inlet buzz can be obtained by inviscid computations only and the computed flow patterns inside and around the inlet are qualitatively consistent with the experimental observations. The dominant frequency of the inlet buzz increases as throttle area decreases, and the computed frequency is approximately 60Hz or 15% lower than the experimental data, but interestingly, this gap is constant for all the test cases and shock structures are similar. Secondly, inviscid calculations are performed to examine the effect regarding angle of attack. It is found that patterns of pressure oscillation histories and distortion due to asymmetric (or three-dimensional) shock structures are substantially affected by angle of attack. The dominant frequency of the inlet buzz, however, does not change noticeably even in regards to a wide range of angle of attacks.

Effect of inlet throttling on thermohydraulic instability in a large scale water-based RCCS: A system-level analysis with RELAP5-3D

  • Zhiee Jhia Ooi;Qiuping Lv;Rui Hu;Matthew Jasica;Darius Lisowski
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1902-1912
    • /
    • 2024
  • This paper presents results from system-level modeling of a water-based reactor cavity cooling system using RELAP5-3D. The computational model is benchmarked with experimental data from a half-scale RCCS test facility at Argonne National Laboratory. The model prediction is first compared with a two-phase oscillatory baseline experimental case where mixed accuracy is obtained. The model shows reasonable prediction of mass flow rate, pressure, and temperature but significant overprediction of void fraction. The model prediction is then compared with a fault case where the inlet of the risers is gradually reduced using a throttling valve. As the valve is closed, the model is able to predict some major flow phenomena observed in the experiment such as the dampening of oscillations, the reintroduction of oscillations, as well as boiling, flashing, and geysering in the risers. However, the timeline of these events are not well captured by the model. The model is also used to investigate the evolution of flow regime in the chimney. This work highlights that the semi-empirical constitutive relations used in RELAP-3D could have a strong influence on the accuracy of the model in two-phase oscillatory flows.

Numerical Analysis of Flow Characteristics around 3D Supersonic Inlet at Various Angle of Attack (받음각이 있는 3차원 초음속 흡입구 주위의 유동진동 해석)

  • Kim, J.;Hong, W.;Kim, C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.218-224
    • /
    • 2011
  • A supersonic inlet at angle of attack has anti-symmetric pressure distribution, and it can make flow instability and structural problem. In this study, numerical analysis of three-dimensional inviscid flow was conducted under various throttle ratio and angle of attack conditions. Throttle ratio was defined as the ratio of the exit area to the smallest cross section area at inlet, and the ratio is controlled from 0 to 2.42. At various angle of attack, the characteristics of steady and unsteady flow around supersonic inlet is observed under different throttling ratios. From these results, pressure recovery curves and pressure history curves were plotted by post processing. Using pressure history data, FFT analysis is also carried out. Through these processes, it shows the tendency of pressure distribution anti-symmetricity and changing dominant frequency as increasing angle of attack.

  • PDF

A Study on Subcritical Instability of Axisymmetric Supersonic inlet (축대칭 초음속 흡입구의 아임계 불안정성 연구)

  • Shin, Phil-Kwon;Park, Jong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.8
    • /
    • pp.29-36
    • /
    • 2004
  • Supersonic inlet buzz can be defined as unstable subcritical operation associated with fluctuating internal pressures and a shock pattern oscillating about the inlet entrance. The flow pulsations could result in flameout in the combustor or even structural damage to the engine. An experimental study was conducted to investigate the phenomenon of supersonic inlet buzz on axisymmetric, external-compression inlet. An inlet model with a cowl lip diameter of 30mm was tested at a free stream Mach number of 2.0. Subcritical instability was investigated by considering the frequency of pressure pulsation and shock wave structure at the inlet entrance. The results obtained show that total pressure recovery ratios were varied from 0.42 to 0.78, and capture area ratio from 0.34 to 0.98. The frequency of the subcritical flow increased with decrease in capture area ratios. Frequency was measured at $224{\sim}240Hz$.

Performance Analysis of Refrigeration System by Adjusting Manual Expansion Valve (수동식 팽창밸브 조정에 의한 냉동시스템의 성능 분석)

  • Yang, Hyung-Suk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.3
    • /
    • pp.113-119
    • /
    • 2011
  • This study analyzed facts affecting the performance of refrigeration systems after throttling actions, by changing the amount of refrigerant according to adjusting the opening of manual expansion valve to 80%, or 20% with vapor compressional refrigeration training equipment. At opening of 20%, the inlet and outlet temperature of compressor, subcooling and superheat, condenser heat, refrigeration effect, flash gas heat, coefficient of performance were higher, while at 80%, condensing pressure, evaporating pressure, compression work were higher, Thus, we could see changes in the amount of refrigerant affect the performance of the refrigeration system.

A Study on the Characteristic of Flow and Burnout in a Boiling Annulus (Part 2, Case of Natural Convection) (불등이중관에 있어서의 유동특성과 번아우트 (제3보, 자연대유의 경우))

  • 조용철
    • Journal of the KSME
    • /
    • v.16 no.2
    • /
    • pp.84-91
    • /
    • 1976
  • An experimental investigation of the natural circulating boiling flow characteristic in three cases of annulus with different outer diameter, and the effect of annular gap size on the burnout behavior is presented. The experimental work was conducted for each case of test section at system pressure of $1kg/cm^2$ and inlet subcooling $0-20^{\circ}C$ in the full range of throttling ratio. As the result, the following facts were found. 1) With the increase of ${\Delta}T_{sub}$, $D_{2}$ and A/A_{o}$, $q_{BO}$ increases on the whole, and with the decrease of ${\Delta}T_{sub}$ and $D_{2}$, hydrodynamic instability is accelerated to happen prematually. 2)With the increase of ${\Delta}T_{sub}$, $D_{2}$ and A/A_{o}$ burnout characteristic shows the high velocitylow quality burnout, and with the decrease, low-velocity-high quality burnout. 3)With the decrease of A/A_{o}$, hyddrodynamic instability is singnificantly restrained and the difference of $q_{BO}$ in each $D_2$ under same condition is gradually reduced, finally converging into $1.9{\times}10^{5}kcal/m^{2}-hr$.

  • PDF

A SIMPLE ANALYTICAL METHOD FOR NONLINEAR DENSITY WAVE TWO-PHASE INSTABILITY IN A SODIUM-HEATED AND HELICALLY COILED STEAM GENERATOR

  • Kim, Seong-O;Choi, Seok-Ki;Kang, Han-Ok
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.841-848
    • /
    • 2009
  • A simple model to analyze non-linear density-wave instability in a sodium-cooled helically coiled steam generator is developed. The model is formulated with three regions with moving boundaries. The homogeneous equilibrium flow model is used for the two-phase region and the shell-side energy conservation is also considered for the heat flux variation in each region. The proposed model is applied to the analysis of two-phase instability in a JAEA (Japan Atomic Energy Agency) 50MWt No.2 steam generator. The steady state results show that the proposed model accurately predicts the six cases of operating temperatures on the primary and secondary sides. The sizes of three regions, the secondary side pressure drop according to the flow rate, and the temperature variation in the vertical direction are also predicted well. The temporal variations of the inlet flow rate according to the throttling coefficient, the boiling and superheating boundaries and the pressure drop in the two-phase and superheating regions are obtained from the unsteady analysis.

Development of a Dynamic Model for Double-Effect LiBr-$H_2O$ Absorption Chillers and Comparison with Experimental Data. (이중효용 흡수식 냉온수기 동특성 모델 개발 및 실험결과 비교)

  • Shin, Young-gi;Seo, Jung-A;Cho, Hyun-Wook;Nam, Sang-Chul;Jeong, Jin-Hee
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.109-114
    • /
    • 2008
  • A dynamic model has been developed to simulate dynamic operation of a real double-effect absorption chiller. Dynamic behavior of working fluids in main components was modeled in first-order nonlinear differential equations based on heat and mass balances. Mass transport mechanisms among the main components were modeled by valve throttling, 'U' tube overflow and solution sub-cooling. The nonlinear dynamic equations coupled with the subroutines to calculate thermodynamic properties of working fluids were solved by a numerical method. The dynamic performance of the model was compared with the test data of a commercial medium chiller. The model showed a good agreement with the test data except for the first 5,000 seconds during which different flow rates of the weak solution caused some discrepancy. It was found that the chiller dynamics is governed by the inlet temperatures of the cooling water and the chilled water when the heat input to the chiller is relatively constant.

  • PDF