• Title/Summary/Keyword: Inlet pipe

Search Result 253, Processing Time 0.021 seconds

A Parametric Study for the Design of Gas-Liquid Centrifugal Separator (기체-액체 원심분리기의 설계를 위한 매개변수 연구)

  • Nagdewe, Suryakant;Lee, S.J.;Kim, H.D.;Kim, D.S.;Kwak, K.M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.218-219
    • /
    • 2008
  • A gas-liquid centrifugal separator is widely used in industry because of its simple geometry and little maintenance. Also, these separators have considerable advantages over filters, scrubbers or precipitators in term of compact design, low pressure drop and higher capacity. A gas-liquid centrifugal separator is a device that utilizes centrifugal force and low pressure to separate liquid from gas by density difference. Design parameters such as length of separation space, swirl vane exit angle, inlet to outlet pipe diameter ratio, models for separation efficiency and low pressure drop as a function of physical dimension are not available in literature. In present study, length of separation space (from vane to gas exit opening) has been studied using CFD. The 3-D Navier-Stokes equations are numerically solved using a fully implicit finite volume scheme. Based upon the obtained solutions, tangential velocities, centrifugal forces, vortices and total pressure losses are analyzed to find the best design parameters.

  • PDF

A Comparative Study on the Fouling Characteristics of River and Tap Water in a Heat Exchanging Model (열교환기 모델내 하천수와 시수의 Fouling 특성 비교)

  • Sung, Sun-Kyung;Suh, Sang-Ho;Roh, Hyung-Woon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.49-54
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanging surface, it is traditionally called fouling. The objective of the present study was to compare the fouling characteristics of river and tap water in a heat exchanging model. FromtheSEM analyses for tap water the $calciteformofCaCO3_{3}$ was formed. For river water, however, the $aragoniteCaCO_{3}$ wasformed.In order to investigate velocity effects on the fouling characteristics in the heat exchanging model, the inlet velocity was varied with 0.5, 1.0 and 1.5 m/s, respectively. The fouling characteristics of river water were quite different from those of tap water. For the case of the 'velocity of 1.5m/s', the overall heat transfer coefficient was reduced up to 26% than that of the 'velocity of 0.5m/s'

  • PDF

Viscoelastic Fluid Flow in a Sudden Expansion Circular Channel as a Model for the Blood Flow Experiments

  • Pak, Bock-Choon;Kim, Cheol-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.233-242
    • /
    • 1990
  • In the current flow visualization studies, the role of non-Newtonian characteristics (such as shearra to dependent viscosity and viscoelasticity ) on flow behavior across the sudden ex- pansion step in a circular pipe as a model for blood flow experiments is investigated over a wide range of Reynolds numbers. The expansion ratios tested are 2.000 and 2.667 and the range of the Reynolds number covered in the current flow visualization tests are 10~35, 000 based on the inlet. diameter. The reattachment longuEs for the viscoelastic fluids in the lami- nar flow regime are found to be much shorter than those for the Newtonian fluid. In addition it decreases significantly with increasing concentration of viscoelastic fluids at the same Reynolds number. However, in the turbulent flow regime, the reattachment length for the viscoelastic fluids Is two or three times longer than those for water, and gradually increases with increasing concentration of viscoelastic solutions, resulting In 25 and 28 step-height dis- tances for 500 and 1, 000 lpm ployacrylamide solutions, respectively. This may be due to the fact that the elasticity in pobacrylamide solutions suppresses the eddy motion and controls separation and reattachment behavior in the sudden expansion pips flow.

  • PDF

Effect of an aspect ratio on thermal stratification in a solar seasonal thermal storage tank (태양열 계간 축열조 내부 열성층화에 대한 탱크 종횡비 영향 연구)

  • Kim, Seong Keun;Jung, Sung Yong
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.2
    • /
    • pp.28-34
    • /
    • 2020
  • In this study, we numerically investigated the thermal stratification in solar seasonal thermal storage tanks. The vertical in/out flows were unsuitable for the thermal stratification in a large scale. The effect of an aspect ratio (AR) on the thermal stratification was investigated. When AR was less than 2, water adheres and flows along the upper wall due to buoyance and the surface effect. Thereafter, hot water flows down and a large scale vortex occurs in entire tank. For high AR, jet flows ejected from the inlet pipe impinges to the opposite wall and splits. The divided flows create two vortex flows in the upper and lower regions. These different flows strongly influence temperature and thermal stratification. The thermal stratification was evaluated in terms of the thermocline thickness and degree of stratification. Compared to ARs, the maximum degree of stratification was obtained with AR of 5 having the minimum thermocline thickness.

Thermal Flow Analysis and Design of KSTAR Thermal Shield Panel by Numerical Method (수치해석을 통한 KSTAR 주장치 열차폐 패널 열.유동 특성해석)

  • 김동락;김광선;노영미;조승연;김승현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.73-77
    • /
    • 2002
  • In order to derive the detailed design of Thermal Shield Cryopanel. which plays a role to make the Tokamak Nuclear Fusion Equipment work at both static and efficient conditions the commercially available software package FLUENT Version 5.3, was utilized. This study investigated the effects of thermal sources and distributions on the temperatures of Lid. Body. Base. and EH-Port Cryopanel by the numerical technique whose grid generations cover the solid and 9as region of the panel. The physical model of the Thermal Shield Cryopanel is that the 10mm diameter of the pipe with 1mm thickness is soldered on the Stainless steel Panel with 4mm thickness. The heat fluxes to the panel are assumed to be by thermal radiation in the vacuum space and by conduction through the supporters. The inlet conditions of Helium gas are 20 atmospheric Pressures and 60K temperature. The panel shapes with cooling Pipes and the operational conditions to keep appropriate temperature distribution of Thermal Shield Cryopanel Have been found and suggested.

Analysis on the Thermal Performance of Flat-plate Solar Collector for Greenhouse Heating(I) (온실 난방을 위한 평판형 태양집열기의 열적성능 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol;Lee, Seung-Hwan;Lee, Suk-Gun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.6
    • /
    • pp.46-56
    • /
    • 1998
  • This study was performed to investigate thermal performances of two different types of flat-plate solar collector systems; natural circulation system and forced circulation system. Conclusions obtained from this study are summarized as follows; 1) In the natural circulation system, the total heat amounts retrieved by starting recovery soon after sunrise were ranged from 10.28 to 17.20MJ/m$^2$, while the total heat amounts retrieved by starting recovery after sunset were ranged from 5.31 to 10.77MJ/m$^2$. 2) The collector efficiency in natural circulation system were ranged from 51.1% to 54.1% when the collected heat was retrieved after sunrise and were 65.8~78.0% when the collected heat was retrieved soon after sunset. 3) According to the regression analysis between fluid flow rates and fluid temperature difference at inlet and outlet of collector pipe, there was high regressive corelations with regression coefficient, r, of 0.982. 4) The collector efficiencies estimated for forced circulation system were 73.1~88.6%, and 78.4~94.8%, and 64.2%~74.5%, respectively when fluid circulation rates were 4.2 l/min, and 7.0 l/min, respectively.

  • PDF

Effect on Ice Slurry Flowing in the Elbow of Various Angle (다양한 각도의 곡관 내에서 아이스슬러리의 유동에 따른 영향)

  • 김규목;박기원;권일욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.142-149
    • /
    • 2004
  • Recently, the government introduced the thermal storage system for reducing the electric power load. Especially, the ice slurry type has gained lots of interest due to its good heat transfer and flowing characteristics. This study was peformed to understand the effects of transporting ice slurry through elbows of various angle. Propylene glycol water solution was used and about 2 mm ice particles were circulated. The experiments were carried out under various conditions, such as concentration and velocity of water solution ranging between 0∼20 wt%, 1.5∼2.5 m/s, respectively. And elbows with 4 different angles of 30$^{\circ}$, 45$^{\circ}$, 90$^{\circ}$, 180$^{\circ}$. The differential pressure and IPF (ice packing factor) between the pipe entry and exit were measured. The tendency of pressure loss and outlet IPF in elbow is that the pressure loss was reduced as concentration and flow velocity of water solution is increased, and low value appeared at 10 wt% and 2.5 m/s. The variation of outlet IPF was compared with the inlet IPF in the range of $\pm$20%.

THERMAL HYDRAULIC ISSUES OF CONTAINMENT FILTERED VENTING SYSTEM FOR A LONG OPERATING TIME

  • Na, Young Su;Ha, Kwang Soon;Park, Rae-Joon;Park, Jong-Hwa;Cho, Song-Won
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.797-802
    • /
    • 2014
  • This study investigated the thermal hydraulic issues in the Containment Filtered Venting System (CFVS) for a long operating time using the MELCOR computer code. The modeling of the CFVS, including the models for pool scrubbing and the filter, was added to the input file for the OPR-1000, and a Station Blackout (SBO) was chosen as an accident scenario. Although depressurization in the containment building as a primary objective of the CFVS was successful, the decontamination feature by scrubbing and filtering in the CFVS for a long operating time could fail by the continuous evaporation of the scrubbing solution. After the operation of the CFVS, the atmosphere temperature in the CFVS became slightly above the water saturation temperature owing to the release of an amount of steam with high temperature from the containment building to the scrubbing solution. Reduced pipe diameters at the inlet and outlet of the CFVS vessel mitigated the evaporation of scrubbing water by controlling the amount of high-temperature steam and the water saturation temperature.

A Study on the Free Surface Vortex in the Pipe System (배관내 자유수면에서 와류현상에 대한 연구)

  • Kim, Sang-Nyung;Jang, Wan-Ho
    • Nuclear Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.311-318
    • /
    • 1992
  • During mid-loop operation of Nuclear Power Plant, to prevent the Decay Heat Removal System (DHRS) from failure due to air entrainment of free surface vortex in the piping system, a set of simulating experiments was performed. Through these experiments, a relation between the non-dimensionalized numbers, such as H/d, Froude number, Reynolds number, was found. It was also found that the perturbation of the system by the disturbance such as pump start, valve operation, etc., has a strong effect on the free surface vortex. Furthermore, from viewpoint of reactor safety, a modified inlet device which is reducer type is strongly recommended for the prevention of air entrainment into DHRS.

  • PDF

Investigation on the Flow Field Upstream of a Centrifugal Pump Impeller

  • Zhang, Yao;Luo, Xianwu;Yi, Yunchi;Zhuang, Baotang;Xu, Hongyuan
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.209-216
    • /
    • 2011
  • The flow upstream of a centrifugal pump impeller has been investigated by both experimental test and numerical simulation. For experimental study, the flow field at four sections in the pump suction is measured by using PIV method. For calculation, the three dimensional turbulent flow for the full flow passage of the pump is simulated based on RANS equations combined with RNG k-$\varepsilon$ turbulence model. From those results, it is noted that at both design lo ad and quarter load condition, the pre-swirl flow whose direction is the same as the impeller rotation exists at all four sections in suction pipe of the pump, and at each section, the pre-swirl velocity becomes obviously larger at higher rotational speed. It is also indicated that at quarter load condition, the low pressure region at suction surface of the vane is large because of the unfavorable flow upstream of the pump impeller.